Introduction Given that we have reached a point in the field of muscle energetics where absolute measurements are warranted to take the area forward, we designed an ergometer, including two force and two displacement transducers, allowing dynamic and isometric knee extension within a MR system and accurate measurements of power output. Methods On the basis of repeated measurements, the force and displacement transducers accuracy was 1% for values ranging from 0 to 394 N and 4% for values ranging from 0 to 20 cm. In addition, measurements were not affected by magnetic field. MRS experiments in exercising muscle were conducted in eight subjects. They performed two standardized dynamic alternate leg extension exercises (25 and 35% of MVC) while the corresponding metabolic changes were measured using (31)P-MRS. Results The mean power output produced during both exercises were 63 +/- 16 and 81 +/- 15 W while the eccentric work was reduced i.e. 12 +/- 14 and 21 +/- 6 W for the moderate and heavy exercise respectively. The corresponding metabolic changes were significant with a 20-40% PCr depletion and an end of exercise pH ranging from 0.02 to 0.70 pH units. Conclusion Overall, the present ergometer allows quadriceps exercise in a MR system and should be useful for future metabolic studies for which reliable and absolute quantification of power output is warranted.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 50 条
  • [1] Accurate work-rate measurements during in vivo MRS studies of exercising human quadriceps
    Gwenael Layec
    Aurélien Bringard
    Christophe Vilmen
    Jean-Paul Micallef
    Yann Le Fur
    Stéphane Perrey
    Patrick J. Cozzone
    David Bendahan
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21 : 227 - 235
  • [2] Accurate work-rate measurements during in vivo MRS studies of human quadriceps exercising muscle
    Layec, G.
    Micallef, J. P.
    Vilmen, C.
    Bringard, A.
    Le Fur, Y.
    Perrey, S.
    Cozzone, P.
    Bendahan, D.
    [J]. FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2009, 23 : 83 - 84
  • [3] Effects of music on work-rate distribution during a cycling time trial
    Atkinson, G
    Wilson, D
    Eubank, M
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2004, 25 (08) : 611 - 615
  • [4] Ventilatory and gas exchange responses during heavy constant work-rate exercise
    Riley, MS
    Cooper, CB
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (01): : 98 - 104
  • [5] 31P MRS studies of exercising human muscle at high temporal resolution
    Boska, MD
    Nelson, JA
    Sripathi, N
    Pipinos, II
    Shepard, AD
    Welch, KMA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (06) : 1145 - 1151
  • [6] A multimode dynamometer for in vivo MRS studies of human skeletal muscle
    Ryschon, TW
    Fowler, MD
    Arai, AA
    Wysong, RE
    Leighton, SB
    Clem, TR
    Balaban, RS
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (06) : 2139 - 2147
  • [7] Aerobic metabolism of human quadriceps muscle: in vivo data parallel measurements on isolated mitochondria
    Rasmussen, UF
    Rasmussen, HN
    Krustrup, P
    Quistorff, B
    Saltin, B
    Bangsbo, J
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2001, 280 (02): : E301 - E307
  • [8] Vibration & work-rate measurements of steam-generator U-tubes in air-water cross-flow
    Janzen, VP
    Hagberg, EG
    Patrick, JNF
    Pettigrew, MJ
    Taylor, CE
    Whan, TG
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON FLUID STRUCTURE INTERACTION, AEROELASTICITY, FLOW INDUCED VIBRATION AND NOISE, PTS A AND B, 2002, : 1019 - 1032
  • [9] RATE OF FATIGUE DURING REPEATED SUBMAXIMAL CONTRACTIONS OF HUMAN QUADRICEPS MUSCLE
    DOLMAGE, T
    CAFARELLI, E
    [J]. CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1991, 69 (10) : 1410 - 1415
  • [10] Two-pedal ergometer for in vivo MRS studies of human calf muscles
    Francescato, MP
    Cettolo, V
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 1000 - 1005