Pitfalls in point-spread-function measurement of computed tomographic system by microphantom reconstruction

被引:1
|
作者
Chen, ZK [1 ]
Ning, R [1 ]
机构
[1] Univ Rochester, Dept Radiol, Rochester, NY 14642 USA
基金
美国国家卫生研究院;
关键词
point spread function; computed tomography; x-ray imaging; edge spread function; aperture effect;
D O I
10.1117/1.1827610
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Intuitively, the point spread function (PSF) of a computed tomographic (CT) system can be determined by the reconstruction of a microphantom (diam<1 mm), such as a microbead for 3-D PSF or a thin wire for 2-D PSF (or line spread function). In fact, this direct method has its own limitations and drawbacks. First, the microphantom (not necessarily infinitesimal) is difficult to be precisely manufactured. Second, the reconstructed volume (containing the micron phantom image) is prone to the uncertainty in digital representation due to the aperture effect associated with grid cells (pixels for 2-D grid or voxels for 3-D grid). Third, the reconstructed digital volume of a microphantom is both material dependent and size dependent, and so is the PSF; this is not convenient for CT system evaluation. We reveal the pitfalls associated with the microphantom-based cone-beam CT PSF measurement by theoretical explanation and experimental demonstration. To avoid the pitfalls, we are in favor of the edge-based techniques for PSF measurement through the use of a macroedge phantom (diam>1 mm). In conclusion, the CT PSF can be efficiently determined by an edge-based technique, such as the iterative edge-blurring algorithm. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET
    Prieto, Elena
    Dominguez-Prado, Ines
    Jose Garcia-Velloso, Maria
    Penuelas, Ivan
    Angel Richter, Jose
    Maria Marti-Climent, Josep
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (02) : 103 - 109
  • [32] Transmission-matrix-based point-spread-function engineering through a complex medium
    Boniface, Antoine
    Mounaix, Mickael
    Blochet, Baptiste
    Piestun, Rafael
    Gigan, Sylvain
    OPTICA, 2017, 4 (01): : 54 - 59
  • [33] Nonlinear delayed fluorescence in confocal scanning microscopy.: Point-spread-function analysis
    Kowalczyk, M
    Martínez-Corral, M
    Rodríguez, CJZ
    OPTICA APPLICATA, 2000, 30 (2-3) : 231 - 238
  • [34] Least-Squares Kirchhoff Depth Migration With Fast Point-Spread-Function Computation
    Yue, Yubo
    Liu, Yujin
    Ye, Yunfei
    Wo, Yukai
    Qian, Zhongping
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2023, 61
  • [35] MEASUREMENT OF THE POINT SPREAD FUNCTION IN THE OCEAN
    VOSS, KJ
    CHAPIN, AL
    APPLIED OPTICS, 1990, 29 (25): : 3638 - 3642
  • [36] Improving the blind restoration of retinal images by means of point-spread-function estimation assessment
    Marrugo, Andres G.
    Millan, Maria S.
    Sorel, Michal
    Kotera, Jan
    Sroubek, Filip
    10TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2015, 9287
  • [37] Point-spread-function enhancement via designing new configuration of collimator in nuclear medicine
    Ashoor, Mansour
    Khorshidi, Abdollah
    RADIATION PHYSICS AND CHEMISTRY, 2022, 190
  • [38] Point spread function optimization for MRI reconstruction
    Tan, H
    Zheng, YB
    2005 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1-5: SPEECH PROCESSING, 2005, : 477 - 480
  • [39] Estimating the point spread function of an imaging system using wavefront measurement
    Mao, Hongjun
    Liang, Yonghui
    Huang, Zongfu
    Liu, Jin
    Jiang, Pengzhi
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: LARGE MIRRORS AND TELESCOPES, 2016, 9682
  • [40] Automatic estimation of point-spread-function for deconvoluting out-of-focus optical coherence tomographic images using information entropy-based approach
    Liu, Guozhong
    Yousefi, Siavash
    Zhi, Zhongwei
    Wang, Ruikang K.
    OPTICS EXPRESS, 2011, 19 (19): : 18135 - 18148