Anteromedial femoral neck plate with cannulated screws for the treatment of irreducible displaced femoral neck fracture in young patients: a preliminary study

被引:28
|
作者
Zhuang, Linbo [1 ]
Wang, Lisheng [1 ]
Xu, Dongming [1 ]
Wang, Zhiyong [1 ]
机构
[1] Shenzhen Univ, Dept Orthoped, Baoan Cent Hosp Shenzhen, Affiliated Hosp 5,Hlth Sci Ctr, Shenzhen 518102, Guangdong, Peoples R China
关键词
Femoral neck fracture; Anteromedial femoral neck plate; Cannulated screws; Open reduction; Avascular necrosis; Nonunion; DYNAMIC HIP SCREW; BLADE PLATE; FIXATION; REDUCTION; NONUNION; MANAGEMENT; NECROSIS; IMPLANT; GRAFT; HEAD;
D O I
10.1007/s00068-018-0972-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Backgrounds Although most displaced femoral neck fractures of young patients can be repositioned successfully by closed reduction, there are still some can not repositioned successfully by this way and open reductions are required. This type of fracture was defined as irreducible displaced femoral neck fracture in this study. The purpose of this study was to introduce a new technique using anteromedial femoral neck plate with cannulated screws fixation by open reduction for the treatment of irreducible displaced femoral neck fractures in young patients. Methods Totally 26 patients with irreducible displaced femoral neck fracture treated by this technique were retrospectively reviewed. This technique included three major steps: open reduction of femoral neck fracture was performed via the modified anterior approach of hip joint, anteromedial femoral neck plate was fixed to the femoral neck, and two cannulated compression screws were inserted in the femoral neck inside. Results All patients were followed up with an average of 18months (range 12-30 months). Radiological and clinical outcomes were evaluated. The fracture union was achieved in 24 patients (92.3%) with an average duration of 4.5 months (range 3.8-10 months). Nonunion was not observed in all cases. Avascular necrosis of femoral head was identified in two patients (7.7%). Clinical outcomes of 24 hips with satisfactory union were evaluated by the Harris Hip Scores (HHS), excellent outcomes were achieved in 20 cases (HHS >= 90), fair outcomes in 3 cases (80 <= HHS < 90), and poor outcome in 1 case (HHS < 80). Conclusions Anteromedial femoral neck plate with cannulated screws fixation by open reduction is an alternative therapeutic method for the irreducible displaced femoral neck fracture in young patients, with low incidence of complications including nonunion and avascular necrosis.
引用
收藏
页码:995 / 1002
页数:8
相关论文
共 50 条
  • [21] Dynamic Hip and Cannulated Screws in Fixation of Adults Femoral Neck Fracture: A Comparative Study
    Al-Kelabi, Adnan Essa
    Mahmoud, Mustafa Shakir
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (03): : 135 - 142
  • [22] Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
    Zhou, Xiao-Qiang
    Li, Zhi-Qiang
    Xu, Ren-Jie
    She, Yuan-Shi
    Zhang, Xiang-Xin
    Chen, Guang-Xiang
    Yu, Xiao
    ORTHOPAEDIC SURGERY, 2021, 13 (06) : 1802 - 1809
  • [23] Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study
    Wang, Yilin
    Han, Na
    Zhang, Dianying
    Zhang, Peixun
    Jiang, Baoguo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [24] Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study
    Yilin Wang
    Na Han
    Dianying Zhang
    Peixun Zhang
    Baoguo Jiang
    Scientific Reports, 12
  • [25] Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study
    Yan, Shuang G.
    Cui, Yiliang
    Li, Di
    Liu, Fanxiao
    Hua, Xingyi
    Schmidutz, Florian
    JOURNAL OF INVESTIGATIVE SURGERY, 2023, 36 (01)
  • [26] Treatment of Delbet II/III Pediatric Femoral Neck Fractures With Proximal Femoral Locking Plate Versus Cannulated Screws
    Haider, Shamrez
    Harris, Timothy J.
    Turner, Alexander C.
    Podeszwa, David A.
    Hartman, Courtney A.
    Morris, William Z.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : 213 - 220
  • [27] Comparison of Femoral Neck System Versus Cannulated Cancellous Screws for the Fixation of Femoral Neck Fracture in Young Adults: A Systematic Review and Meta-Analysis
    Gupta, Govind K.
    Rai, Arpita
    Mandal, Subhankar
    Rani, Sudha
    Shekhar, Shubhendu
    Halder, Subhajit
    Prasad, Pancham
    Kumar, Amit
    Ul Haque, Zeya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [28] Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures
    Nan, Chong
    Li, Yanjun
    Liu, Yuxiu
    Ma, Liang
    Ma, Zhanbei
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (04) : 1161 - 1170
  • [29] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [30] Femoral neck system vs. cannulated screws on treating femoral neck fracture: a meta-analysis and system review
    Zhou, Yimin
    Li, Zongyang
    Lao, Kecheng
    Wang, Zixiu
    Zhang, Li
    Dai, Shiyou
    Fan, Xiao
    FRONTIERS IN SURGERY, 2023, 10