Establishment of ELISA on 384-well microplate for AFP, CEA, CA 19-9, CA 15-3, CA 125, and PSA-ACT: Higher sensitivity and lower reagent cost

被引:19
|
作者
Wu, TL
Sun, YC
Chang, PY
Tsao, KC
Sun, CF
Wu, JT
机构
[1] Univ Utah, ARUP, Hlth Sci Ctr, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Pathol, Hlth Sci Ctr, Salt Lake City, UT 84108 USA
[3] Chang Gung Mem Hosp, Dept Pathol, Taipei 10591, Taiwan
关键词
tumor marker; ELISA; 384-well microplate; 96-well microplate;
D O I
10.1002/jcla.10104
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The 384-well microplate contains four times as many wells as the regular 96-well microplate. Establishing enzyme linked immunosorbent assay (ELISA) on 384-well microplate should lead to savings in reagents and specimens. To determine that ELISAs on 384-well microplate have acceptable assay precision, ELISAs for tumor markers, including AFP, PSA-ACT, CEA, CA 125, CA 15-3, and CA 19-9, were compared to the same ELISAs established on 96-well microplate. We found that ELISAs established on 384-well microplate had similar sensitivity and covered similar concentration ranges as ELISAs on 96-well microplate. All within-day and day-to-day precisions for the 384-ELISA had %CV less than 10%. Compared to ELISA on 96-well microplate, 384-ELISA used less reagents, less specimen, and exhibited approximately a two-fold increase in sensitivity. Overall cost of the 384-384-ELISA was also greatly reduced. Our results suggest that 384-ELISA is suitable for use in routine clinical laboratories. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 41 条
  • [21] A multicentre evaluation of the CA 15-3 assay, CA 19-9 assay and CA 125 II assay on the Bayer Immuno 1(R) system
    Romer, M
    Haeckel, R
    Brux, B
    Sinha, P
    Raiko, I
    Krieg, M
    Stark, M
    Seidel, D
    Hubner, U
    Schmitz, G
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (08): : 637 - 644
  • [22] IMMUNOASSAY OF CEA, CA 19-9, CA 125, AND CA 15-3 ON THE AUTOMATED SYSTEMS ES-300 AND ES-600 - METHODOLOGICAL EVALUATION FROM A MULTICENTER COLLABORATIVE STUDY
    ZUCCHELLI, GC
    PILO, A
    JAWOREK, D
    MASINI, S
    CHIESA, MR
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1992, 30 (12): : 875 - 879
  • [23] The Efficacy of Serum Carcinoembryonic Antigen (CEA), Cancer Antigen 125 (CA125), Carbohydrate Antigen 19-9 (CA19-9), Carbohydrate Antigen 15-3 (CA15-3), α-Fetoprotein (AFP) and Human Chorionic Gonadotropin (hCG) Levels in Determining the Malignancy of Solitary Pulmonary Nodules
    Bekci, T. T.
    Senol, T.
    Maden, E.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (02) : 438 - 445
  • [24] Significance of Serum Tumor Markers Carcinoembryonic Antigen, CA 19-9, CA 125, and CA 15-3 in Pre-Orthotopic Liver Transplantation Evaluation
    Pissaia, A., Jr.
    Bernard, D.
    Scatton, O.
    Soubrane, O.
    Conti, F.
    Calmus, Y.
    TRANSPLANTATION PROCEEDINGS, 2009, 41 (02) : 682 - 684
  • [25] Diagnostic value of CEA, CA 15-3, CA 19-9, CYFRA 21-1, NSE and TSA assay in pleural effusions
    Alatas, F
    Alatas, Ö
    Metintas, M
    Çolak, Ö
    Harmanci, E
    Demir, S
    LUNG CANCER, 2001, 31 (01) : 9 - 16
  • [26] METHOD COMPARISON FOR CA 15-3, CA 19-9, AND CA 125 DETERMINATION USING THE NEW LOCI TECHNIQUE OF DIMENSION VISTA 1500 AND IMMULITE 2000 XPI
    Zur, Berndt
    Holdenrieder, Stefan
    Albers, Eike
    Walgenbach-Bruenagel, Gisela
    Stoffel-Wagner, Birgit
    JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2012, 33 (04): : 435 - 445
  • [27] Clinical Performance of CEA, CA19-9, CA15-3, CA125 and AFP in Gastrointestinal Cancer Using LOCI™-based Assays
    Dolscheid-Pommerich, Ramona C.
    Manekeller, Steffen
    Walgenbach-Bruenagel, Gisela
    Kalff, Joerg C.
    Hartmann, Gunther
    Wagner, Birgit Stoffel
    Holdenrieder, Stefan
    ANTICANCER RESEARCH, 2017, 37 (01) : 353 - 359
  • [28] Combined Evaluation of AFP, CA15-3, CA125, CA19-9, and CEA Tumor Markers in Patients with Hepatitis B and C
    Assmar, Mehdi
    Yeganeh, Sara
    Mansourghanaei, Fariborz
    Amirmozafari, Nour
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2016, 45 (12) : 1645 - 1651
  • [29] The reference intervals for CA125, CA15-3, CA19-9, CA72-4, AFP, CEA, NSE and CYFRA21-1
    Yang, Jingjing
    Tang, Aiguo
    Ma, Junfen
    Sun, Xiaoxu
    Ming, Liang
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2019, 79 (1-2): : 71 - 74
  • [30] CEA、AFP、CA125、CA15-3、CA19-9检测对恶性肿瘤的诊断价值探讨
    朱海龙
    现代医药卫生, 2006, (22) : 3422 - 3423