Enhancement and control of acoustic cavitation yield by low-level dual frequency sonication: A subharmonic analysis

被引:44
|
作者
Hasanzadeh, Hadi [1 ]
Mokhtari-Dizaji, Manijhe [1 ]
Bathaie, S. Zahra [2 ]
Hassan, Zuhair M. [3 ]
Nilchiani, Vahid [4 ]
Goudarzi, H. [5 ]
机构
[1] Tarbiat Modares Univ, Fac Med Sci, Dept Med Phys, Tehran, Iran
[2] Tarbiat Modares Univ, Fac Med Sci, Dept Clin Biochem, Tehran, Iran
[3] Tarbiat Modares Univ, Fac Med Sci, Dept Immunol, Tehran, Iran
[4] Pars Nahand Engn Co, Tehran, Iran
[5] Engn Res Inst, Control Res Dept, Tehran, Iran
关键词
Dual frequency sonication; Acoustic cavitation; Subharmonic analysis; Cavitation area; SINGLE-BUBBLE SONOLUMINESCENCE; SOLID TUMORS; GAS-BUBBLES; ULTRASOUND; LIQUIDS; FIELD; STIMULATION; IRRADIATION; GENERATION; EXCITATION;
D O I
10.1016/j.ultsonch.2010.07.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Evaluation of inertial cavitation is a significant problem where this mechanism of action is responsible for therapeutic applications such as drug delivery. It has shown that using multiple frequencies one is able to enhance and control induced cavitation. In this study, we used different sonication frequencies as 28 kHz, 130 kHz, 1 MHz, 3 MHz and their dual combinations to enhance acoustic cavitation. At each frequency, two different intensities were used and the subharmonic amplitude of each frequency in combinations was measured. It was observed that in combinations which include 28 kHz, the cavitation activity is enhanced. The 28 kHz subharmonic amplitude was used to compare these protocols in their ability to enhance cavitation. Besides, the area of cavitation damage was determined using an aluminum foil. Our results showed that the inertial cavitation activity increased at higher intensities and there is a significant correlation between the subharmonic amplitude and sonication intensity at each frequency (R > 0.90). In addition, simultaneous combined dual-frequency orthogonal sonication at 28 kHz with other frequencies used can significantly increase the inertial cavitation activity as compared to the algebraic sum of the individual ultrasound irradiations in 28 kHz subharmonic frequency. The 28 kHz subharmonic amplitude for 28 kHz (0.04 W/cm(2)) and 3 MHz (2 and 1 W/cm(2)) combined dual frequency were about 4.6 and 1.5 times higher than that obtained from the algebraic sum of 28 kHz and 3 MHz irradiation, respectively. Also the 28 kHz subharmonic amplitude for combination of 28 kHz (0.04 W/cm(2)) and 1 MHz (2 and 1 W/cm(2)) were about 2.4 and 1.6 times higher than that obtained with their algebraic sum. Among different combinations, the continuous mode for two ultrasound sources of 28 kHz (0.04 W/cm(2)) and 3 MHz (2 W/cm(2)) is more effective than other combinations (p-value < 0.05). The results of effective irradiation area showed no damaged aluminum foil in MHz sonication alone. However, there is significant difference between the effective irradiation area of combined dual frequency 28 kHz and 3 MHz with other irradiation modes (p-value < 0.05) and it is limited locally. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:394 / 400
页数:7
相关论文
共 50 条
  • [12] Subjective annoyance caused by indoor low-level and low frequency noise and control method
    Di, GQ
    Zhang, BJ
    Shang, Q
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2005, 17 (01) : 135 - 140
  • [13] Efficacy of Acupoints Dual-Frequency Low-Level Laser Therapy on Knee Osteoarthritis
    Liao, Fang-Yin
    Lin, Chien-Lin
    Lo, Sui-Foon
    Chang, Chun-Ching
    Liao, Wen-Yen
    Chou, Li-Wei
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2020, 2020
  • [14] INTERFERENCE CONTROL IN LOW-LEVEL I-129 ANALYSIS
    BRAUER, FP
    STREBIN, RS
    FAGER, JE
    KAYE, JH
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 72 (1-2): : 501 - 514
  • [15] ATHEROSCLEROTIC SOFT PLAQUE REGRESSION USING TRANSCUTANEOUS LOW-LEVEL COMBINED DUAL-FREQUENCY SONICATION ACCOMPANIED BY HIGH-DOSE ATORVASTATIN AND PESDA MICROBUBBLES ADMINISTRATION
    Mehrad, H.
    Mokhtari-Dizaji, M.
    Ghanaati, H.
    ATHEROSCLEROSIS, 2016, 252 : E187 - E187
  • [16] Low-Level Characterization of Expressive Head Motion Through Frequency Domain Analysis
    Ding, Yu
    Shi, Lei
    Deng, Zhigang
    IEEE TRANSACTIONS ON AFFECTIVE COMPUTING, 2020, 11 (03) : 405 - 418
  • [17] Low-frequency dual-frequency ultrasound-mediated microbubble cavitation for transdermal minoxidil delivery and hair growth enhancement
    Ai-Ho Liao
    Keng-Hsien Lin
    Ho-Chiao Chuang
    Chih-Hung Tsai
    Yi-Chun Lin
    Chih-Hung Wang
    Cheng-Ping Shih
    Hao-Li Liu
    Scientific Reports, 10
  • [18] Low-frequency dual-frequency ultrasound-mediated microbubble cavitation for transdermal minoxidil delivery and hair growth enhancement
    Liao, Ai-Ho
    Lin, Keng-Hsien
    Chuang, Ho-Chiao
    Tsai, Chih-Hung
    Lin, Yi-Chun
    Wang, Chih-Hung
    Shih, Cheng-Ping
    Liu, Hao-Li
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [19] Investigation of control configurations for low-level single and dual piloted rotorcraft combat mission tasks
    Bivens, Courtland C.
    Haworth, Loran A.
    Shively, Robert J.
    Journal of the American Helicopter Society, 1988, 33 (04) : 47 - 54
  • [20] OSTEOSARCOMA AND LOW-LEVEL RADIUM EXPOSURE IN DRINKING WATER - A CASE CONTROL ANALYSIS
    Gleason, Jessie
    Cohn, Perry
    Burger, Stasia
    Fagliano, Jerald
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2013, 177 : S43 - S43