A fluorometric histidine biosensor based on the use of a quencher-labeled Cu(II)-dependent DNAzyme

被引:19
|
作者
Chen, Zhuling [1 ]
He, Qun [2 ]
Zhao, Mengmeng [3 ]
Lin, Cuiying [1 ]
Luo, Fang [3 ,4 ]
Lin, Zhenyu [3 ]
Chen, Guonan [3 ]
机构
[1] Fuzhou Univ, Coll Chem, Fuzhou 350116, Fujian, Peoples R China
[2] Fuzhou Univ, Sch Law, Fuzhou 350116, Fujian, Peoples R China
[3] Fuzhou Univ, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ, Key Lab Anal & Detect Food Safety, Fuzhou 350116, Fujian, Peoples R China
[4] Fuzhou Univ, Coll Biol Sci & Engn, Fuzhou 350116, Fujian, Peoples R China
关键词
DNAzyme; Cofactors; FAM-labeled DNA; Catalytic beacon; Fluorometry; Human urine samples; AMINO-ACIDS; AMPLIFIED DETECTION; FLUORESCENT-PROBE; DNA; ELECTROPHORESIS; OXIDATION; ENSEMBLE; CLEAVAGE; PLASMA;
D O I
10.1007/s00604-017-2425-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe a biosensor for histidine that is based on the use of a DNAzyme catalytic beacon. The Cu(II)-dependent DNA-cleaving DNAzyme (Cu-Enzyme) was modified with a quencher (BHQ1) at its 5' end, and the corresponding substrate strand (Cu-Sub) was modified with a quencher and the FAM fluorophore at its 5' and 3' ends, respectively. The green FAM emission of the system is completely quenched after the Cu-Enzyme is hybridized with Cu-Sub. The presence of Cu(II) triggers the cleavage of the Cu-Sub so that fluorescence recovers. Histidine forms a complex with Cu(II) ion. The complex is not capable of cleaving Cu-Sub effectively so that the fluorescence of the system is not restored. These findings were exploited to design a robust and sensitive assay for the determination of histidine. Fluorescence intensity is linearly related to the concentration of histidine in the range between 0.05 and 40 mu M, and the detection limit is 20 nM. The method has been successfully applied to the determination of histidine in (spiked) human urine and gave satisfying results.
引用
收藏
页码:4015 / 4020
页数:6
相关论文
共 50 条
  • [41] Development of biosotption-based algal biosensor for Cu(II) using Tetraselmis chuii
    Alpat, Sibel Kilinc
    Alpat, Senol
    Kutlu, Banu
    Ozbayrak, Ozge
    Buyukisik, H. Baha
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 128 (01) : 273 - 278
  • [42] Flim of Physiological Free CU(II) in Living Cells with a Protein-Based Biosensor
    McCranor, Bryan J.
    Zeng, Hui-Hui
    Szmacinski, Henryk
    Fierke, Carol A.
    Lakowicz, Joseph R.
    Thompson, Richard B.
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 470 - 470
  • [43] A novel fluorescence aptamer biosensor for trace Pb(II) based on gold-doped carbon dots and DNAzyme synergetic catalytic amplification
    Li, Dan
    Yuan, Xu
    Li, Chongning
    Luo, Yanghe
    Jiang, Zhiliang
    JOURNAL OF LUMINESCENCE, 2020, 221
  • [44] Fluorescent Character of Cu(I/II) Complexes with Bisquinoline-based Ligands and Fluorometric Detection of Reductants
    Makoto Saga
    Tatsuya Anamushi
    Wakayo Miyahara
    Shigeo Yamazaki
    Keiitsu Saito
    Analytical Sciences, 2015, 31 : 185 - 189
  • [45] Fluorescent Character of Cu(I/II) Complexes with Bisquinoline-based Ligands and Fluorometric Detection of Reductants
    Saga, Makoto
    Anamushi, Tatsuya
    Miyahara, Wakayo
    Yamazaki, Shigeo
    Saito, Keiitsu
    ANALYTICAL SCIENCES, 2015, 31 (03) : 185 - 189
  • [46] Detection of Cu2+ in Water Based on Histidine-Gold Labeled Multiwalled Carbon Nanotube Electrochemical Sensor
    Zhu, Rilong
    Zhou, Gangqiang
    Tang, Fengxia
    Tong, Chunyi
    Wang, Yeyao
    Wang, Jinsheng
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 2017
  • [47] An electrochemical aptamer-based biosensor targeting Plasmodium falciparum histidine-rich protein II for malaria diagnosis
    Lo, Young
    Cheung, Yee-Wai
    Wang, Lin
    Lee, Megan
    Figueroa-Miranda, Gabriela
    Liang, Shaolin
    Mayer, Dirk
    Tanner, Julian Alexander
    BIOSENSORS & BIOELECTRONICS, 2021, 192
  • [48] Fluorescence lifetime imaging of physiological free Cu(II) levels in live cells with a Cu(II)-selective carbonic anhydrase-based biosensor
    McCranor, Bryan J.
    Szmacinski, Henryk
    Zeng, Hui Hui
    Stoddard, Andrea K.
    Hurst, Tamiika
    Fierke, Carol A.
    Lakowicz, J. R.
    Thompson, Richard B.
    METALLOMICS, 2014, 6 (05) : 1034 - 1042
  • [49] Electrochemiluminescent lead biosensor based on GR-5 lead-dependent DNAzyme for Ru(phen)32+ intercalation and lead recognition
    Gao, Ai
    Tang, Chun-Xia
    He, Xi-Wen
    Yin, Xue-Bo
    ANALYST, 2013, 138 (01) : 263 - 268
  • [50] Fabrication of a Fluorophore/Liquid-Crystal-Based Oligopeptide Biosensor for the Detection of Cu (II) Ions
    ul Amin, Noor
    Yang Kun-Lin
    Majeed, Nasir
    Siddiqi, Humaira Masood
    CHEMISTRYSELECT, 2021, 6 (25): : 6607 - 6618