HPGe detectors timing using pulse shape analysis techniques

被引:17
|
作者
Crespi, F. C. L. [1 ]
Vandone, V. [1 ]
Brambilla, S. [2 ]
Camera, F. [1 ]
Million, B. [2 ]
Riboldi, S. [1 ]
Wieland, O. [2 ]
机构
[1] Univ Milan, Dipartimento Fis, I-20122 Milan, Italy
[2] INFN Sez Milano, I-20133 Milan, Italy
关键词
HPGe time resolution; Pulse shape analysis; RS algorithm; Gamma spectroscopy; HPGe Detectors; GAMMA-RAY TRACKING; GRETA; ARRAY; PERFORMANCE;
D O I
10.1016/j.nima.2010.02.273
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work the Pulse Shape Analysis has been used to improve the time resolution of High Purity Germanium (HPGe) detectors. A set of time aligned signals was acquired in a coincidence measurement using a coaxial HPGe and a cerium-doped lanthanum chloride (LaGl(3):Ce) scintillation detector. The analysis using a Constant Fraction Discriminator (CFD) time output versus the HPGe signal shape shows that time resolution ranges from 2 to 12 ns depending on the slope in the initial part of the signal. An optimization procedure of the CFD parameters gives the same final time resolution (8 ns) as the one achieved after a correction of the CFD output based on the current pulse maximum position. Finally, an algorithm based on Pulse Shape Analysis was applied to the experimental data and a time resolution between 3 and 4 ns was obtained, corresponding to a 50% improvement as compared with that given by standard CFDs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [21] Correction for hole trapping in AGATA detectors using pulse shape analysis
    Bruyneel, B.
    Birkenbach, B.
    Eberth, J.
    Hess, H.
    Pascovici, Gh.
    Reiter, P.
    Wiens, A.
    Bazzacco, D.
    Farnea, E.
    Michelagnoli, C.
    Recchia, F.
    EUROPEAN PHYSICAL JOURNAL A, 2013, 49 (05): : 1 - 9
  • [22] PULSE SHAPE AND TIMING PROBLEM IN SOLID STATE DETECTORS - A REVIEW PAPER
    QUARANTA, AA
    MARTINI, M
    OTTAVIAN.G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (02) : 35 - &
  • [23] Analysis of simulated and measured pulse shapes of closed-ended HPGe detectors
    Kroll, T
    Peter, I
    Elze, TW
    Gerl, J
    Happ, T
    Kaspar, M
    Schaffner, H
    Schremmer, S
    Schubert, R
    Vetter, K
    Wollersheim, HJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (03): : 489 - 496
  • [24] Analysis of simulated and measured pulse shapes of closed-ended HPGe detectors
    Johann Wolfgang Goethe-Universitaet, Frankfurt am Main, Frankfurt am Main, Germany
    Nucl Instrum Methods Phys Res Sect A, 3 (489-496):
  • [25] Systematic effects in pulse shape analysis of HPGe detector signals for 0νββ
    Gehman, V. M.
    Elliott, S. R.
    Mei, D. -M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (01): : 83 - 92
  • [26] A pulse-shape analysis approach to 3-D position determination in large-volume segmented HPGe detectors
    Gatti, E
    Casati, G
    Geraci, A
    Pullia, A
    Ripamonti, G
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 346 - 351
  • [27] Experimental determination of reference pulses for highly segmented HPGe detectors and application to Pulse Shape Analysis used in γ-ray tracking arrays
    Li, H. J.
    Ljungvall, J.
    Michelagnoli, C.
    Clement, E.
    Dudouet, J.
    Desesquelles, P.
    Lopez-Martens, A.
    de France, G.
    EUROPEAN PHYSICAL JOURNAL A, 2018, 54 (11):
  • [28] COMPARATIVE TIMING PERFORMANCE OF LARGE VOLUME HPGE GERMANIUM DETECTORS
    PAULUS, TJ
    RAUDORF, TW
    COYNE, B
    TRAMMELL, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 544 - 548
  • [29] Digital signal processing techniques for HPGe detectors operation
    Riboldi, Stefano
    Cattadori, Carla
    D'Andrea, Valerio
    Benato, Giovanni
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [30] SmartPET: Applying HPGe and pulse shape analysis to small-animal PET
    Cooper, R. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Mather, A. R.
    Nolan, P. J.
    Scraggs, D. P.
    Turk, G.
    Hall, C. J.
    Lazarus, I.
    Berry, A.
    Beveridge, T.
    Gillam, J.
    Lewis, R. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 313 - 317