Fabrication of robust SiC ceramic membrane filter with optimized flap for industrial coal-fired flue gas filtration

被引:15
|
作者
Wei, Wei [1 ]
Han, Yaru [1 ]
Chen, Jiahao [1 ]
Han, Feng [3 ]
Zou, Dong [2 ]
Zhang, Feng [1 ]
Zhong, Zhaoxiang [1 ,2 ]
Xing, Weihong [1 ]
机构
[1] Nanjing Tech Univ, Natl Engn Res Ctr Special Separat Membrane, State Key Lab Mat Oriented Chem Engn, Nanjing 211816, Peoples R China
[2] Nanjing Tech Univ, Sch Environm Sci & Engn, Nanjing 211816, Peoples R China
[3] Jiangsu Jiulang High Technol Co Ltd, Nanjing 211806, Peoples R China
基金
中国国家自然科学基金;
关键词
SiC filter; Optimized flap; Bending strength; Thermal expansion; Hot gas filtration; POROUS CERAMICS; STRENGTH; PERFORMANCE; COMPOSITE; MULLITE;
D O I
10.1016/j.seppur.2022.122075
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Silicon carbide (SiC) filter candles are particularly suitable for the purification of industrial coal-fired flue at high temperatures. However, the filters are prone to break due to the lack of bending strength, especially at the filter flap, which limits its application field and service life. In this work, the SiC filter candles with optimized flap for the removal of fly ash from the industrial coal-fired flue gas were presented. The bimodal particle size distri-bution of SiC powders were employed to prepare the SiC filter flap to increase the number of neck connections among the SiC particles. The bending strength of filter flap was enhanced from 18.0 MPa to 37.0 MPa while the gas permeability did not exhibit obvious decline. Besides, the SiC filter candles presented a good thermal shock resistance due to the similar coefficient of thermal expansion of SiC filter flap (5.6 x 10-6 /K, 300-450 degrees C) and pipe body (5.0 x 10-6 /K, 300-450 degrees C). When the dust-containing flue gas with high temperature (300-450 degrees C) passed through the SiC membrane filtration equipment, dust was removed efficiently, and downstream equip-ment were protected from blocking and fouling. When the surface velocity of flue gas was set at 0.8 m/min and the back flushing pressure was set at 0.6 MPa, the pressure drop was fairly stable with minor fluctuation from 2420 Pa to 2700 Pa. Meanwhile, the outlet dust concentration and filtration efficiency of coal-fired flue gas were below 5.0 mg/m3 and above 99.98 %, respectively. This work provided a robust and high-efficiency SiC filter for the purification of industrial flue gas containing submicron-sized solid particles.
引用
收藏
页数:10
相关论文
共 21 条
  • [1] Influence of Deposited Carbonblack Particles on Pressure Drop with Ceramic Ultra-Filtration for Treatment of Coal-Fired Flue Gas
    Zhang, Wei
    Lu, Cheng
    Dong, Pengfei
    Fang, Yiwei
    Yin, Yanshan
    Hu, Zhangmao
    Wang, Huiying
    Ruan, Min
    Xu, Huifang
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2018, 51 (07) : 566 - 575
  • [2] Membrane separation system for coal-fired flue gas reclamation: Process planning and initial design
    Ruan, Xuehua
    Xiao, Hongyan
    Shou, Jianxiang
    Huang, Aibin
    Xiao, Wu
    He, Gaohong
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 97 (03): : 717 - 726
  • [3] Removal of coal-fired flue gas organic matter by activated carbon injection coupled with bag filter
    Lü, Hao
    Ma, Xiuwei
    Hou, Yong
    Yang, Linjun
    [J]. Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2021, 51 (03): : 503 - 510
  • [4] Review on membrane wettability of membrane CO2 absorption method from coal-fired flue gas
    Zhang, Weifeng
    Li, Juan
    Wang, Qiuhua
    Deng, Zhaoxiong
    Wang, Lulu
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (08): : 3866 - 3873
  • [5] Analysis of the Effect of the Ceramic Membrane Module Based on Ebsilon Software on Water Recovery of Flue Gas from Coal-fired Power Plants
    Jiang, Chao
    Jia, Chenhui
    Liu, Pei
    Li, Zheng
    [J]. 30TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A-C, 2020, 48 : 421 - 426
  • [6] Effect of NO2 on PPS Filter used in Coal-fired Power Plant Flue Gas Dust Collection
    Chang, Deqiang
    Liu, Jingxian
    Mao, Ning
    Zhang, Haiyan
    Chen, Baozhi
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [7] Prospecting for Oleaginous and Robust Chlorella spp. for Coal-Fired Flue-Gas-Mediated Biodiesel Production
    Kim, Bohwa
    Praveenkumar, Ramasamy
    Choi, Eunji
    Lee, Kyubock
    Jeon, Sang Goo
    Oh, You-Kwan
    [J]. ENERGIES, 2018, 11 (08):
  • [8] Membrane processes for carbon capture from coal-fired power plant flue gas: A modeling and cost study
    Ramasubramanian, Kartik
    Verweij, Hendrik
    Ho, W. S. Winston
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2012, 421 : 299 - 310
  • [9] Simulation and techno-economic analysis of moisture and heat recovery from original flue gas in coal-fired power plants by macroporous ceramic membrane
    Zhao, Chunhao
    Wang, Zhengfeng
    Gao, Dan
    Chen, Haiping
    Zhang, Heng
    [J]. ENERGY, 2022, 259
  • [10] Study on the Effects of Wet Flue Gas Desulfurization on Particulate Matter Emission from Industrial Coal-Fired Power Plants
    Wang, Anyu
    Li, Shuran
    Zheng, Qinzhen
    Zhang, Shuo
    Zhang, Shihao
    Wang, Zhihao
    Liu, Zhen
    Yan, Keping
    [J]. SEPARATIONS, 2023, 10 (06)