Enzyme Biosensors Systems Based on Co-Modification of Carbon Nanotubes and Enzyme for Detection of Glucose in Food

被引:12
|
作者
Zou, Bin [1 ,2 ]
Wang, Pengyun [1 ]
Xia, Jiaojiao [3 ]
Qian, Jingya [1 ]
Yan, Yan [1 ]
Mutombo, Jessica [1 ]
机构
[1] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Jiangnan Univ, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[3] Jiangsu Univ, Sch Chem & Chem Engn, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
CYCLODEXTRIN-FUNCTIONALIZED MWCNT; REDUCED GRAPHENE OXIDE; DIRECT ELECTROCHEMISTRY; GOLD NANOPARTICLES; ELECTRON-TRANSFER; PLATFORM; HYBRID; WATER;
D O I
10.1149/1945-7111/ac064d
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, a new biosensor based on modified glucose oxidase (mGOx) and carbon nanotubes was designed. Firstly, the glucose oxidase(GOx) was chemically modified by ionic liquid to obtain a new enzyme mGOx. Secondly, beta cyclodextrin (beta-CD) was combined with multi-wall carbon nanotubes (MWCNTs) to prepare beta-CD/MWCNTs composite carrier. Finally, mGOx was loaded on the beta-CD/MWCNTs composite material to construct a new biosensor mGOx/beta-CD/MWCNTs/GCE. And it was used for the determination of glucose in honey. The prepared enzyme biosensor could sensitively detect glucose, the detection range was between 50 mu M similar to 1.15 mM, the sensitivity was 35.44 mu A center dot mM(-1)cm(-2), and the detection limit was as low as 0.27 mu M. The biosensor had good stability (95.8% current retention within two weeks), reproducibility (n = 10, relative standard deviation (RSD) = 1.6%) and anti-interference. More importantly, actual samples test showed that the glucose biosensor could be successfully applied to the detection of glucose in honey.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multi-walled carbon nanotubes for the immobilization of enzyme in glucose biosensors
    Wang, SG
    Zhang, Q
    Wang, RL
    Yoon, SF
    Ahn, J
    Yang, DJ
    Tian, JZ
    Li, JQ
    Zhou, Q
    ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (09) : 800 - 803
  • [2] Research on Detection Method of Enzyme Injection Glucose Biosensors Based on Temperature
    Gao Xue-Jin
    Li Jiao
    Lyu Xin-Yu
    Wang Pu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 97 - 103
  • [3] Enzyme based amperometric Biosensors for food analysis
    Prodromidis, MI
    Karayannis, MI
    ELECTROANALYSIS, 2002, 14 (04) : 241 - 261
  • [4] Enzyme-Coated Carbon Nanotubes Form Ultrasmall Biosensors
    Steven Trohalaki
    MRS Bulletin, 2003, 28 : 547 - 548
  • [5] Enzyme-coated carbon nanotubes form ultrasmall biosensors
    Trohalaki, S
    MRS BULLETIN, 2003, 28 (08) : 547 - 548
  • [6] Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
    Florescu, M
    Brett, CMA
    TALANTA, 2005, 65 (02) : 306 - 312
  • [7] Functional carbon nanotube material-based enzyme biosensors for glucose sensing
    Zhang, NY
    Xie, JN
    Varadan, VK
    Smart Structures and Materials 2005: Smart Electronics, Mems, BioMems, and Nanotechnology, 2005, 5763 : 157 - 166
  • [8] New method for the detection of enzyme immobilized on Si-based glucose biosensors
    Libertino, S.
    Aiello, V.
    Fiorenza, P.
    Fichera, M.
    Scandurra, A.
    Sinatra, F.
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 478 - +
  • [9] CNTs-based biosensors for enzyme detection
    Saguin, Nongawende S. Gloria
    Maulik, Granthana
    Cao, Xuejiao
    Luo, Xuan
    Nag, Anindya
    Gao, Jingrong
    Deng, Shanggui
    Wong, Jonathan W. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 377
  • [10] Organized enzyme assemblies on carbon nanotubes toward nanoscale biosensors.
    Lenihan, JS
    Gavalas, V
    Wang, JQ
    Andrews, R
    Bachas, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U80 - U81