Diagnosis of transformer insulation condition using recovery voltage measurements

被引:0
|
作者
Talib, MA [1 ]
Ghazali, NAM [1 ]
Christie, M [1 ]
Zakaria, W [1 ]
Hashim, I [1 ]
Uthman, S [1 ]
Jamali, MN [1 ]
机构
[1] TNB REs Sdn Bhd, Kawasan Inst Penyelidikan, Kajang 43000, Malaysia
关键词
transformer; insulation system; recovery voltage; measurement;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Moisture is one of the factors that cause transformer insulation degradation. The detection of moisture in oil and paper insulation is crucial in determining the health of transformer insulation system. High moisture content severely degrades the insulating strength of oil and paper and may eventually cause failure. In recent years, new diagnostic and monitoring techniques have been promoted to complement the classical insulation resistance, power dissipation factor and polarization index measurements. The new test method described in this paper is based on analysis of the polarization spectrum traced from the results of Recovery Voltage Measurements (RVM). This method makes possible assessment of the condition of oil/paper insulation system. This paper shows some applications of RVM for determining the moisture level in the power transformers. The possible use of this method as a diagnostic tool for evaluates ageing trends or actual state of insulation is also discussed.
引用
下载
收藏
页码:329 / 332
页数:4
相关论文
共 50 条
  • [21] Analysis of Dielectric Response Measurements for Condition Assessment of Oil-Paper Transformer Insulation
    Koch, Maik
    Prevost, Thomas
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1908 - 1915
  • [22] Ageing Condition Assessment of Transformer Insulation in Visual Domain Using DCNN
    Vatsa, Aniket
    Hati, Ananda Shankar
    Khadkikar, Vinod
    2022 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS, PEDES, 2022,
  • [23] Diagnosis and monitoring of high-voltage insulation using computerized analysis of partial discharge measurements
    Wahidabanu, RSD
    Panneerselvam, MA
    Udayakumar, K
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 1998, 23 (04): : 171 - 177
  • [24] High Voltage Transformer Insulation Evaluation Using a Measurement Expert System
    Grigorescu, S. D.
    Ghita, O. M.
    Covrig, M.
    Potarniche, I.
    2011 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2011,
  • [25] Practical experience on transformer insulation condition assessment
    Homagk, C.
    Leibfried, T.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 238 - +
  • [26] High Voltage Power Transformer Insulation Design
    Ziomek, W.
    Vijayan, K.
    Boyd, D.
    Kuby, K.
    Franchek, M.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 211 - 215
  • [27] Advanced Online Moisture Measurements in Transformer Insulation Using Optical Sensors
    Ansari, Muhammad A.
    Martin, Daniel
    Saha, Tapan Kumar
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (06) : 1803 - 1810
  • [28] Advanced Online Moisture Measurements in Transformer Insulation Using Optical Sensors
    Ansari, Muhammad A.
    Martin, Daniel
    Saha, Tapan Kumar
    IEEE Transactions on Dielectrics and Electrical Insulation, 2020, 27 (06): : 1803 - 1810
  • [29] Influence of acid value on recovery voltage parameters of transformer oil-paper insulation system
    Wang, X. (xjwang1987@126.com), 1600, Electric Power Automation Equipment Press (33):
  • [30] Flow electrification measurements of transformer insulation using a Couette flow facility
    Washabaugh, AP
    Zahn, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (02) : 161 - 181