WIRC plus Pol: A Low-resolution Near-infrared Spectropolarimeter

被引:21
|
作者
Tinyanont, Samaporn [1 ]
Millar-Blanchaer, Maxwell A. [2 ]
Nilsson, Ricky [1 ]
Mawet, Dimitri [1 ,2 ]
Knutson, Heather [3 ]
Kataria, Tiffany [2 ]
Vasisht, Gautam [2 ]
Henderson, Charles [4 ]
Matthews, Keith [1 ]
Serabyn, Eugene [2 ]
Milburn, Jennifer W. [1 ]
Hale, David [1 ]
Smith, Roger [1 ]
Vissapragada, Shreyas [3 ]
Santos, Louis D., Jr. [1 ]
Kekas, Jason [5 ]
Escuti, Michael J. [5 ,6 ]
机构
[1] CALTECH, Dept Astron, 1200 E Calif Blvd,MC 249-17, Pasadena, CA 91125 USA
[2] CALTECH, Jet Prop Lab, 4800 Oak Grove Dr, Pasadena, CA 91109 USA
[3] CALTECH, Div Geol & Planetary Sci, 1200 E Calif Blvd, Pasadena, CA 91125 USA
[4] Cornell Univ, Dept Astron, 616A Space Sci Bldg, Ithaca, NY 14853 USA
[5] ImagineOptix, Cary, NC 27519 USA
[6] North Carolina State Univ, Dept Elect & Comp Engn, Raleigh, NC USA
基金
美国国家科学基金会;
关键词
instrumentation: polarimeters; methods: data analysis; methods: observational; techniques: polarimetric; WAVELENGTH DEPENDENCE; POLARIZATION;
D O I
10.1088/1538-3873/aaef0f
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
WIRC+Pol is a newly commissioned low-resolution (R similar to 100), near-infrared (J and H bands) spectropolarimetry mode of the Wide-field InfraRed Camera (WIRC) on the 200 inch Hale Telescope at Palomar Observatory. The instrument utilizes a novel polarimeter design based on a quarter-wave plate and a polarization grating (PG), which provides full linear polarization measurements (Stokes I, Q, and U) in one exposure. The PG also has high transmission across the J and H bands. The instrument is situated at the prime focus of an equatorially mounted telescope. As a result, the system only has one reflection in the light path providing minimal telescope induced polarization. A data reduction pipeline has been developed for WIRC+Pol to produce linear polarization measurements from observations. WIRC+Pol has been on-sky since 2017 February. Results from the first year commissioning data show that the instrument has a high dispersion efficiency as expected from the polarization grating. We demonstrate the polarimetric stability of the instrument with rms variation at 0.2% level over 30 minutes for a bright standard star (J = 8.7). While the spectral extraction is photon noise limited, polarization calibration between sources remain limited by systematics, likely related to gravity dependent pointing effects. We discuss instrumental systematics we have uncovered in the data, their potential causes, along with calibrations that are necessary to eliminate them. We describe a modulator upgrade that will eliminate the slowly varying systematics and provide polarimetric accuracy better than 0.1%.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Infrared low-resolution spectra of symbiotic stars
    Feng Wang
    Pei-sheng Chen
    [J]. Astrophysics and Space Science, 2002, 282 : 669 - 682
  • [32] Test results and operating configuration of the Calibration unit for the near-infrared spectropolarimeter SPIRou
    Perruchot, S.
    Hobson, M.
    Bouchy, F.
    Dolon, F.
    Boisse, I.
    Moreau, F.
    Sottile, R.
    Wildi, F.
    [J]. GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VII, 2018, 10702
  • [33] Detecting Aircraft With a Low-Resolution Infrared Sensor
    Jakubowicz, Jeremie
    Lefebvre, Sidonie
    Maire, Florian
    Moulines, Eric
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2012, 21 (06) : 3034 - 3041
  • [34] Infrared low-resolution spectra of symbiotic stars
    Wang, F
    Chen, PS
    [J]. ASTROPHYSICS AND SPACE SCIENCE, 2002, 282 (04) : 669 - 682
  • [35] Infrared Low-Resolution Spectra of HAEBE Stars
    Chen P. S.
    [J]. 天文研究与技术, 1999, (S1) : 344 - 348
  • [36] Infrared Low-Resolution Spectra of HAEBE Stars
    Chen P S Wang X H He J H Yunnan Observatory and United Laboratory for Optical Astronomy The Chinese Academy of SciencesKunming China National Astronomical Observatories CAS China
    [J]. 云南天文台台刊, 1999, (S1) - 348
  • [37] UNIVERSAL SPECTROPOLARIMETER BASED ON OVERTONE CIRCULAR-DICHROISM MEASUREMENTS IN THE NEAR-INFRARED REGION
    TRAN, CD
    GRISHKO, VI
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3639 - 3643
  • [38] QUANTITATIVE ANALYSES BY EXTREMELY LOW-RESOLUTION INFRARED SPECTROSCOPY
    HANNEMAN, WW
    [J]. APPLIED SPECTROSCOPY, 1968, 22 (5P1) : 572 - &
  • [39] RESOLUTION AND STRAY LIGHT IN NEAR-INFRARED SPECTROSCOPY
    KAYE, W
    [J]. APPLIED OPTICS, 1975, 14 (08): : 1977 - 1986
  • [40] LOW-RESOLUTION BROAD-BAND INFRARED SPECTROGRAPH
    HACKWELL, JA
    WARREN, DW
    [J]. OPTICAL ENGINEERING, 1993, 32 (12) : 3102 - 3104