Novel method for a flexible double sided microelectrode fabrication process

被引:2
|
作者
Doerge, Thomas [1 ]
Kammer, S. [1 ]
Hanauer, M. [1 ]
Sossalla, Adam [1 ]
Steltenkamp, S. [1 ]
机构
[1] Fraunhofer Inst Biomed Engn, Dept Med Engn, Neuro Prosthet Grp, D-66386 St Ingbert, Germany
来源
BIOENGINEERED AND BIOINSPIRED SYSTEMS IV | 2009年 / 7365卷
关键词
Neuroprosthetics; double sided flexible micro electrodes; polyimide; flexible substrate; ELECTRODE ARRANGEMENTS; STIMULATION; INTERFACES; ARRAYS; DESIGN;
D O I
10.1117/12.821649
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Flexible devices with integrated micro electrodes are widely used for neuronal as well as myogenic stimulation and recording applications. One main intention by using micro electrodes is the ability of placing an appropriate amount of electrodes on the active sites. With an increasing number of single electrodes the selectivity for signal acquirement and analysis is significantly improved. The further advantage of small and elastic structures inside the biological tissue is the perfect fit. This lead to lower traumatisation of the nerve and muscle fibres during and after acute and chronically surgery. Different designed and structured flexible micro electrodes have been developed at the IBMT based on polyimide as substrate material over the last years including cuff, intrafascicular and shaft electrodes. All these systems are generally built up as single sided devices which reduce the possible electrode site half the area. Especially for shaft and intrafascicular applications having double sided electrode arrangement would increase the selectivity enormous. So areas on both sides can be monitored simultaneously. Recent developments of double sided flexible electrode systems lead to promising results especially for varied signal recording. Though these developments revealed some challenges in the field of micromachining including low yield rates. In this work we describe a new technical approach to develop double sided flexible micro electrode systems with a reproducible high yield rate. Prototypes of intrafascicular and intramuscular electrode systems have been developed and investigated by the means of electrochemical characterisation and mechanical behaviour. Additional investigations have been performed with scanning electron microscopy. We also give an outlook to future in vitro and in vivo experiments to investigate the application performance of the developed systems
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Double-sided Arc Welding Process
    Zhang, Y. M. m
    Male, A. T.
    Losch, B.
    Kvidahl, L.
    Ludwig, M.
    Emmerson, J.
    TRENDS IN WELDING RESEARCH, PROCEEDINGS, 2006, : 149 - +
  • [32] Fabrication process for a flexible tag microlab
    Abad, E.
    Mazzolai, B.
    Juarros, A.
    Gomez, D.
    Mondini, A.
    Sayhan, I.
    Krenkow, A.
    Becker, Th.
    SMART SENSORS, ACTUATORS, AND MEMS III, 2007, 6589
  • [33] Flexible balloon actuators and fabrication process
    Micro and Nano Electromechanical Systems Laboratory, Northwestern Polytechnical University, Xi'an 710072, China
    Hangkong Xuebao, 2009, 10 (1961-1966):
  • [34] STANFORD-UNIVERSITY GENERAL-PURPOSE MICROELECTRODE FABRICATION PROCESS
    KOVACS, GTA
    STORMENT, CW
    LIANG, DH
    WHITE, RL
    ROSEN, JM
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1651 - 1652
  • [35] PASSIVE MICROELECTRODE ARRAYS FOR RECORDING OF NEURAL SIGNALS - A SIMPLIFIED FABRICATION PROCESS
    PECKERAR, M
    SHAMMA, SA
    REBBERT, M
    KOSAKOWSKI, J
    ISAACSON, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (09): : 2276 - 2280
  • [36] A novel method for fabrication of self-aligned double microlens arrays
    Ho, Jeng-Rong
    Shih, Teng-Kai
    Cheng, J. W. John
    Sung, Cheng-Kuo
    Chen, Chia-Fu
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 135 (02) : 465 - 471
  • [37] Fabrication of double-sided thallium bromide strip detectors
    Hitomi, Keitaro
    Nagano, Nobumichi
    Onodera, Toshiyuki
    Kim, Seong-Yun
    Ito, Tatsuya
    Ishii, Keizo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 823 : 15 - 19
  • [38] A Novel Fabrication Method for Flexible SOI Substrate Based on Trench Refilling with Polydimethylsiloxane
    Zhang Cang-Hai
    Yang Yi
    Wang Yu-Feng
    Zhou Chang-Jian
    Shu Yi
    Tian He
    Ren Tian-Ling
    CHINESE PHYSICS LETTERS, 2013, 30 (08)
  • [39] A Novel Fabrication Method for Flexible SOI Substrate Based on Trench Refilling with Polydimethylsiloxane
    张沧海
    杨轶
    王宇峰
    周长见
    束逸
    田禾
    任天令
    Chinese Physics Letters, 2013, 30 (08) : 122 - 125
  • [40] Templated Nano Electrodeposition: Novel Method for Mass Fabrication of Flexible Plasmonic Metasurfaces
    Zhou, Bin
    Wen, Baohua
    Li, Guohua
    Wu, Mingxi
    Cai, Jingxuan
    Zhou, Jianhua
    ADVANCED SENSOR RESEARCH, 2023, 2 (10):