Anesthesia awareness and the bispectral index

被引:556
|
作者
Avidan, Michael S. [1 ]
Zhang, Lini [1 ]
Burnside, Beth A. [1 ]
Finkel, Kevin J. [1 ]
Searleman, Adam C. [1 ]
Selvidge, Jacqueline A. [1 ]
Saager, Leif [1 ]
Turner, Michelle S. [1 ]
Rao, Srikar [1 ]
Bottros, Michael [1 ]
Hantler, Charles [1 ]
Jacobsohn, Eric [1 ]
Evers, Alex S. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Anesthesiol, St Louis, MO 63110 USA
来源
NEW ENGLAND JOURNAL OF MEDICINE | 2008年 / 358卷 / 11期
关键词
D O I
10.1056/NEJMoa0707361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Awareness during anesthesia is a serious complication with potential long-term psychological consequences. Use of the bispectral index (BIS), developed from a processed electroencephalogram, has been reported to decrease the incidence of anesthesia awareness when the BIS value is maintained below 60. In this trial, we sought to determine whether a BIS-based protocol is better than a protocol based on a measurement of end-tidal anesthetic gas (ETAG) for decreasing anesthesia awareness in patients at high risk for this complication. Methods: We randomly assigned 2000 patients to BIS-guided anesthesia (target BIS range, 40 to 60) or ETAG-guided anesthesia (target ETAG range, 0.7 to 1.3 minimum alveolar concentration [MAC]). Postoperatively, patients were assessed for anesthesia awareness at three intervals (0 to 24 hours, 24 to 72 hours, and 30 days after extubation). Results: We assessed 967 and 974 patients from the BIS and ETAG groups, respectively. Two cases of definite anesthesia awareness occurred in each group (absolute difference, 0%; 95% confidence interval [CI], -0.56 to 0.57%). The BIS value was greater than 60 in one case of definite anesthesia awareness, and the ETAG concentrations were less than 0.7 MAC in three cases. For all patients, the mean (+/-SD) time-averaged ETAG concentration was 0.81+/-0.25 MAC in the BIS group and 0.82+/-0.23 MAC in the ETAG group (P=0.10; 95% CI for the difference between the BIS and ETAG groups, -0.04 to 0.01 MAC). Conclusions: We did not reproduce the results of previous studies that reported a lower incidence of anesthesia awareness with BIS monitoring, and the use of the BIS protocol was not associated with reduced administration of volatile anesthetic gases. Anesthesia awareness occurred even when BIS values and ETAG concentrations were within the target ranges. Our findings do not support routine BIS monitoring as part of standard practice. (ClinicalTrials.gov number, NCT00281489.).
引用
收藏
页码:1097 / 1108
页数:12
相关论文
共 50 条
  • [11] Prevention of Awareness by Using Bispectral Index Monitoring in a Patient with History of Awareness
    Yasir, Muhammad
    Sophie, Salma
    [J]. JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2015, 25 (04): : S4 - S5
  • [12] Detection of awareness with the bispectral index:: Two case reports
    Luginbühl, M
    Schnider, TW
    [J]. ANESTHESIOLOGY, 2002, 96 (01) : 241 - 243
  • [13] How do you use bispectral index effectively for preventing re-awareness during general anesthesia?
    Choi, Won Joon
    Kim, Yun Hong
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (01) : 1 - 2
  • [14] What really predicts "Depth of anesthesia"? Bispectral index
    Glass, PSA
    [J]. NEW BALANCED ANESTHESIA, 1998, 1164 : 77 - 83
  • [15] Recovery of bispectral index: Isoflurane vs desflurane anesthesia
    Guignard, B
    Menigaux, C
    Ben Boukhatem, A
    Chauvin, M
    [J]. ANESTHESIOLOGY, 1998, 89 (3A) : U180 - U180
  • [16] Bispectral index monitoring: Optimizing anesthesia in rigid bronchoscopy
    Adiyeke, Ozal
    Sarban, Onur
    Mendes, Ergun
    Akca, Hilal
    Turan, Engin Ihsan
    Demirkol, Baris
    Ozgul, Mehmet Akif
    Gumus Ozcan, Funda
    [J]. TUBERKULOZ VE TORAKS-TUBERCULOSIS AND THORAX, 2024, 72 (03):
  • [17] Electromyographic activity on the bispectral index during combined anesthesia
    Panousis, Periklis
    Koch, Thea
    Heller, Axel R.
    [J]. ANESTHESIA AND ANALGESIA, 2006, 103 (06): : 1605 - 1605
  • [18] The bispectral index during induction of anesthesia with midazolam and propofol
    Hoffman, WE
    Zsigmond, E
    Albrecht, RF
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1996, 8 (01) : 15 - 20
  • [19] Comparison between cerebral state index and bispectral index during desflurane anesthesia
    Cho, Sang-Hyeon
    Kim, Sung-Su
    Hyun, Dong-Min
    Yoon, Hyeong-Suk
    Han, Jung-Woo
    Kim, Jin Sun
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2018, 71 (06) : 447 - 452
  • [20] The effect of different stages of neuromuscular block on the bispectral index and the bispectral index-XP under remifentanil/propofol anesthesia
    Dahaba, AA
    Mattweber, M
    Fuchs, A
    Zenz, W
    Rehak, PH
    List, WF
    Metzler, H
    [J]. ANESTHESIA AND ANALGESIA, 2004, 99 (03): : 781 - 787