Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy

被引:125
|
作者
Leung, Christopher Kai-shun [1 ]
Cheng, Arthur Chak Kwan [1 ]
Chong, Kelvin Kam Lung [1 ]
Leung, King Sai [1 ]
Mohamed, Shaheeda [1 ]
Lau, Charles Sing Lok [1 ]
Cheung, Carol Yim Lui [1 ]
Chu, Geoffrey Chin-hung [1 ]
Lai, Ricky Yiu Kwong [1 ]
Pang, Calvin Chi Pui [1 ]
Lam, Dennis Shun Chiu [1 ]
机构
[1] Chinese Univ Hong Kong, Hong Kong Eye Hosp, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1167/iovs.06-1315
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the relationships between optic disc measurements, obtained by an optical coherence tomograph and a confocal scanning laser ophthalmoscope, and myopia. METHODS. One hundred thirty-three eyes from 133 healthy subjects with mean spherical equivalent -6.0 +/- 4.2 D ( range, -13.13 to + 3.25 D) were analyzed. Optic disc measurements including disc area, rim area, cup area, cup-to-disc area, and vertical and horizontal ratios were obtained with an optical coherence tomograph (StratusOCT; Carl Zeiss Meditec Inc., Dublin, CA) and a confocal scanning laser ophthalmoscope (Heidelberg Retina Tomograph, HRT 3; Heidelberg Engineering, GmbH, Dossenheim, Germany). The modified axial length method derived from prior published work was used to correct the OCT measurements for ocular magnification. Bland-Altman plots were used to evaluate the agreement for each optic disc parameter. Associations between optic disc area and axial length/spherical equivalent were evaluated by linear regression analysis. RESULTS. Disc area increased with the axial length/negative spherical equivalent in the HRT and the corrected OCT measurements although opposite directions of associations were found when the OCT measurements were not corrected for magnification. The difference of the corrected OCT and HRT disc area (corrected OCT disc area minus HRT disc area) was correlated with the axial length (r = 0.195, P = 0.025). When the ametropia was limited to -8.0 to +4.0 D, the correlations became insignificant in the HRT. Using the corrected OCT measurements, disc area, rim area, and cup area, cup-to-disc area, and cup-to-disc horizontal and vertical ratios were significantly larger than those measured by the HRT, with a span of 95% limits of agreement at 1.99, 1.33, and 1.86 mm(2) for the areas, 0.34, 0.53, and 0.58 for the ratios, respectively. CONCLUSIONS. While optic disc area generally increased with the axial length and myopic refraction, the HRT measurements demonstrated that optic disc size was largely independent of axial length and refractive error between -8 and +4 D. OCT may overestimate optic disc size in myopic eyes and results in poor agreement between the two instruments.
引用
收藏
页码:3178 / 3183
页数:6
相关论文
共 50 条
  • [1] Longitudinal Evaluation of Optic Disc Measurement Variability With Optical Coherence Tomography and Confocal Scanning Laser Ophthalmoscopy
    Lin, Dusheng
    Leung, Christopher Kai Shun
    Weinreb, Robert N.
    Cheung, Carol Yim Lui
    Li, Haitao
    Lam, Dennis Shun Chiu
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (02) : 101 - 106
  • [2] Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy
    Schuman, JS
    Wollstein, G
    Farra, T
    Hertzmark, E
    Aydin, A
    Fujimoto, JG
    Paunescu, LA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 504 - 512
  • [3] Evaluation of the influence of tilt of optic disc on the measurement of optic disc variables obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy
    Park, CY
    Kim, YT
    Kee, C
    [J]. JOURNAL OF GLAUCOMA, 2005, 14 (03) : 210 - 214
  • [4] Correlations Between Digital Planimetry and Optical Coherence Tomography, Confocal Scanning Laser Ophthalmoscopy in Assessment of Optic Disc Parameters
    Buteikiene, Dovile
    Paunksnis, Alvydas
    Barzdziukas, Valerijus
    Zaliuniene, Dalia
    Balciuniene, Iurate Vilma
    Jegelevicius, Darius
    [J]. MEDICINA-LITHUANIA, 2012, 48 (03): : 150 - 158
  • [6] Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters
    Foo, Li-Lian
    Perera, Shamira A.
    Cheung, Carol Y.
    Allen, John C.
    Zheng, Yingfeng
    Loon, Seng-Chee
    Wong, Tien Y.
    Aung, Tin
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (04) : 576 - 580
  • [7] Comparison of Optic Disc Topographic Measurements Using Fourier-Domain Optical Coherence Tomography and Confocal Scanning Laser Ophthalmoscopy in Glaucoma Patients and Normal Subjects
    Schulze, A.
    Lamparter, J.
    Pfeiffer, N.
    Hoffmann, E. M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] Assessment of the Optic Disc Morphology Using Spectral-Domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
    Calvo, Pilar
    Ferreras, Antonio
    Abadia, Beatriz
    Ara, Mirian
    Figus, Michele
    Pablo, Luis E.
    Frezzotti, Paolo
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [9] Combined multiplanar optical coherence tomography and confocal scanning ophthalmoscopy
    Podoleanu, AG
    Dobre, GM
    Cucu, RG
    Rosen, R
    Garcia, P
    Nieto, J
    Will, D
    Gentile, R
    Muldoon, T
    Walsh, J
    Yannuzzi, LA
    Fisher, Y
    Orlock, D
    Weitz, R
    Rogers, JA
    Dunne, S
    Boxer, A
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 86 - 93
  • [10] Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients
    Fanihagh, Farsad
    Kremmer, Stephan
    Anastassiou, Gerasimos
    Schallenberg, Maurice
    Steuhl, Klaus-Peter
    Selbach, Michael
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2015, 9 : 41 - 48