Real-time PCR assay is superior to other methods for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran

被引:16
|
作者
Kazemiha, Vahid Molla [1 ]
Bonakdar, Shahin [1 ]
Amanzadeh, Amir [1 ]
Azari, Shahram [1 ]
Memarnejadian, Arash [2 ]
Shahbazi, Shirin [3 ]
Shokrgozar, Mohammad Ali [1 ]
Mahdian, Reza [4 ]
机构
[1] Pasteur Inst Iran, Natl Cell Bank Iran, Tehran, Iran
[2] Pasteur Inst Iran, Dept Hepatitis & AIDS, Tehran, Iran
[3] Tarbiat Modares Univ, Dept Med Genet, Fac Med Sci, Tehran, Iran
[4] Pasteur Inst Iran, Dept Mol Med, Biotechnol Res Ctr, Tehran, Iran
关键词
Cell culture; Real-time PCR; DAPI staining; PCR; Mycoplasma contamination; RAPID DETECTION; CULTURES; DNA; SENSITIVITY; PREVENTION;
D O I
10.1007/s10616-015-9862-0
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Mycoplasmas are the most important contaminants of cell cultures throughout the world. They are considered as a major problem in biological studies and biopharmaceutical economic issues. In this study, our aim was to find the best standard technique as a rapid method with high sensitivity, specificity and accuracy for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Thirty cell lines suspected to mycoplasma contamination were evaluated by five different techniques including microbial culture, indirect DNA DAPI staining, enzymatic mycoalert(A (R)) assay, conventional PCR and real-time PCR. Five mycoplasma-contaminated cell lines were assigned as positive controls and five mycoplasma-free cell lines as negative controls. The enzymatic method was performed using the mycoalert(A (R)) mycoplasma detection kit. Real-time PCR technique was conducted by PromoKine diagnostic kits. In the conventional PCR method, mycoplasma genus-specific primers were designed to analyze the sequences based on a fixed and common region on 16S ribosomal RNA with PCR product size of 425 bp. Mycoplasma contamination was observed in 60, 56.66, 53.33, 46.66 and 33.33 % of 30 different cell cultures by real-time PCR, PCR, enzymatic mycoalert(A (R)), indirect DNA DAPI staining and microbial culture methods, respectively. The analysis of the results of the different methods showed that the real-time PCR assay was superior the other methods with the sensitivity, specificity, accuracy, predictive value of positive and negative results of 100 %. These values were 94.44, 100, 96.77, 100 and 92.85 % for the conventional PCR method, respectively. Therefore, this study showed that real-time PCR and PCR assays based on the common sequences in the 16S ribosomal RNA are reliable methods with high sensitivity, specificity and accuracy for detection of mycoplasma contamination in cell cultures and other biological products.
引用
收藏
页码:1063 / 1080
页数:18
相关论文
共 50 条
  • [21] Characterization of a novel Mycoplasma cynos real-time PCR assay
    Tallmadge, Rebecca L.
    Anderson, Renee
    Mitchell, Patrick K.
    Forbes, Zachary C.
    Werner, Brenda
    Gioia, Gloria
    Moroni, Paolo
    Glaser, Amy
    Thachil, Anil J.
    Goodman, Laura B.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2020, 32 (06) : 793 - 801
  • [22] Real-time RT-PCR detection of retroviral contaminations of cells and cell lines
    Müller, K
    Wirth, M
    CYTOTECHNOLOGY, 2002, 38 (1-2) : 147 - 153
  • [23] Real-time RT-PCR detection of retroviral contaminations of cells and cell lines
    Katja Müller
    Manfred Wirth
    Cytotechnology, 2002, 38 : 147 - 153
  • [24] Detection of Mycoplasma (Eperythrozoon) suis by real-time PCR
    Gattinger, B.
    Spergser, J.
    Wille-Plazzai, W.
    Kolodziejek, J.
    Tichy, A. G.
    Joachim, A.
    WIENER TIERARZTLICHE MONATSSCHRIFT, 2008, 95 (1-2): : 22 - 27
  • [25] Development of real-time PCR for detection of Mycoplasma hominis
    Agata Baczynska
    Helle F Svenstrup
    Jens Fedder
    Svend Birkelund
    Gunna Christiansen
    BMC Microbiology, 4
  • [26] A Real-Time PCR for Detection and Quantification of Mycoplasma ovipneumoniae
    Yang, Falong
    Dao, Xiaofang
    Rodriguez-Palacios, Alex
    Feng, Xufei
    Tang, Cheng
    Yang, Xiaonong
    Yue, Hua
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2014, 76 (12): : 1631 - 1634
  • [27] A One-Step Real-Time PCR Assay for Rapid Prenatal Diagnosis of Sickle Cell Disease and Detection of Maternal Contamination
    Catherine Costa
    Serge Pissard
    Emmanuelle Girodon
    Danièle Huot
    Michel Goossens
    Molecular Diagnosis, 2003, 7 (1) : 45 - 48
  • [28] Real-time quantitative PCR assay for rapid detection of murine virus contamination in bioproducts
    Luling Guo
    Zhe Zhang
    Rui Gong
    Gengfu Xiao
    Virologica Sinica, 2014, (03) : 193 - 195
  • [29] Real-time quantitative PCR assay for rapid detection of murine virus contamination in bioproducts
    Luling Guo
    Zhe Zhang
    Rui Gong
    Gengfu Xiao
    Virologica Sinica, 2014, 29 (03) : 193 - 195
  • [30] Development of a rotor-gene real-time PCR assay for the detection and quantification of Mycoplasma genitalium
    Mueller, Etienne E.
    Venter, Johanna M. E.
    Magooa, Mahlape P.
    Morrison, Charles
    Lewis, David A.
    Mavedzenge, Sue Napierala
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 88 (02) : 311 - 315