Carbon nanotube-plasma polymer-based amperometric biosensors: Enzyme-friendly platform for ultrasensitive glucose detection

被引:11
|
作者
Muguruma, Hitoshi [1 ]
Matsui, Yasunori [1 ]
Shibayama, Yu [1 ]
机构
[1] Shibaura Inst Technol, Dept Elect Engn, Koto Ku, Tokyo 1358548, Japan
关键词
enzyme; electrochemistry; plasma polymer; carbon nanotube; glucose;
D O I
10.1143/JJAP.46.6078
中图分类号
O59 [应用物理学];
学科分类号
摘要
An amperometric enzyme biosensor fabricated with carbon nanotubes (CNTs) and plasma-polymerized thin films (PPFs) is reported. A mixture of the enzyme glucose oxidase (GOD) and a CNT film is sandwiched with 10-nm-thick acetonitrile PPFs. Under PPF layer was deposited onto a sputtered gold electrode. To facilitate the electrochemical communication between the CNT layer and GOD, CNT was treated with oxygen plasma. The device with single-walled CNTs showed a sensitivity higher than that of multimalled CNTs. The glucose biosensor showed ultrasensitivity (a sensitivity of 40 mu A mM(-1) cm(-2), a correlation coefficient of 0.992, a linear response range of 0.025-1.9 mM, a detection limit of 6.2 mu M at S/N = 3, +0.8 V vs Ag/AgCl), and a rapid response (< 4 s in reaching 95% of maximum response). This high performance is attributed to the fact that CNTs have excellent electrocatalytic activity and enhance electron transfer, and that PPFs and/or the plasma process for CNTs are the enzyme-friendly platform, i.e., a suitable design of the interface between GOD and CNTs.
引用
收藏
页码:6078 / 6082
页数:5
相关论文
共 34 条
  • [21] Amperometric biosensor based on multilayer containing carbon nanotube, plasma-polymerized film, electron transfer mediator phenothiazine, and glucose dehydrogenase
    Hoshino, Tatsuya
    Sekiguchi, Shin-ichiro
    Muguruma, Hitoshi
    BIOELECTROCHEMISTRY, 2012, 84 : 1 - 5
  • [22] Ultrasensitive multiwall carbon nanotube-mesoporous MCM-41 hybrid-based platform for the electrochemical detection of ascorbic acid
    Vaschetti, Virginia M.
    Viada, Benjamin N.
    Tamborelli, Alejandro
    Eimer, Griselda A.
    Rivas, Gustavo A.
    Dalmasso, Pablo R.
    ANALYST, 2022, 147 (10) : 2130 - 2140
  • [23] Biomonitoring of Organophosphorus Agent Exposure by Reactivation of Cholinesterase Enzyme Based on Carbon Nanotube-Enhanced Flow-Injection Amperometric Detection
    Du, Dan
    Wang, Jun
    Smith, Jordan N.
    Timchalk, Charles
    Lin, Yuehe
    ANALYTICAL CHEMISTRY, 2009, 81 (22) : 9314 - 9320
  • [24] Nanohybrid electrocatalyst based on cobalt phthalocyanine-carbon nanotube-reduced graphene oxide for ultrasensitive detection of glucose in human saliva
    Adeniyi, Omotayo
    Nwahara, Nnamdi
    Mwanza, Daniel
    Nyokong, Tebello
    Mashazi, Philani
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [25] Surface engineered metal-organic framework-based electrochemical biosensors for enzyme-mimic ultrasensitive detection of glucose: recent advancements and future perspectives
    Arivazhagan, Mani
    Pavadai, Rajaji
    Murugan, Nagaraj
    Jakmunee, Jaroon
    ANALYTICAL METHODS, 2024, 16 (38) : 6474 - 6486
  • [26] A hierarchical cobalt/carbon nanotube hybrid nanocomplex-based ratiometric fluorescent nanosensor for ultrasensitive detection of hydrogen peroxide and glucose in human serum
    Pengcheng Qian
    Yingnan Qin
    Yanlong Lyu
    Yunfei Li
    Lei Wang
    Shuo Wang
    Yaqing Liu
    Analytical and Bioanalytical Chemistry, 2019, 411 : 1517 - 1524
  • [27] A hierarchical cobalt/carbon nanotube hybrid nanocomplex-based ratiometric fluorescent nanosensor for ultrasensitive detection of hydrogen peroxide and glucose in human serum
    Qian, Pengcheng
    Qin, Yingnan
    Lyu, Yanlong
    Li, Yunfei
    Wang, Lei
    Wang, Shuo
    Liu, Yaqing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (08) : 1517 - 1524
  • [28] Comparison of Cobalt Hexacyanoferrate and Poly(Neutral Red) Modified Carbon Film Electrodes for the Amperometric Detection of Heavy Metals Based on Glucose Oxidase Enzyme Inhibition
    Attar, Aisha
    Ghica, M. Emilia
    Amine, Aziz
    Brett, Christopher M. A.
    ANALYTICAL LETTERS, 2015, 48 (04) : 659 - 671
  • [29] A self-cascade system based on Ag nanoparticle/single-walled carbon nanotube nanocomposites as an enzyme mimic for ultrasensitive detection of l-cysteine
    Li, Feifei
    Hu, Congcong
    Su, Wenen
    Liang, Hao
    Xiao, Fubing
    Liu, Jinquan
    Tan, Yan
    Yang, Shengyuan
    ANALYTICAL METHODS, 2023, 15 (26) : 3251 - 3258
  • [30] A sensing platform of molecular imprinted polymer-based polyaniline/carbon paste electrodes for simultaneous potentiometric determination of alfuzosin and solifenacin in binary co-formulation and spiked plasma
    Wadie, Mina
    Marzouk, Hoda M.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    Tantawy, Mahmoud A.
    ANALYTICA CHIMICA ACTA, 2022, 1200