The gradient of retinal functional changes during acute intraocular pressure elevation

被引:136
|
作者
Bui, BV [1 ]
Edmunds, B [1 ]
Cioffi, GA [1 ]
Fortune, B [1 ]
机构
[1] Devers Eye Inst, Discoveries Sight, Portland, OR 97232 USA
关键词
D O I
10.1167/iovs.04-0421
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To characterize retinal function during a period of acutely elevated intraocular pressure (IOP) across a wide range of IOPs, including those typically observed in animals with experimental glaucoma. METHODS. Unilateral elevation of IOP was achieved manometrically in adult Brown Norway rats ( nine experimental groups; n = 4-7 in each; 10-100 mm Hg and sham control). Full-field ERGs were recorded simultaneously from treated and control eyes, beginning 75 minutes after IOP elevation. Scotopic ERG stimuli were brief white flashes (-6.1 to 2.7 log cd-s/m(2)). Photopic ERGs were recorded (1.2-2.7 log cd-s/m(2)) after 15 minutes of light adaptation (150 cd/m(2)). Relative amplitude (treated/control, %) of ERG components versus IOP was described with a cumulative normal function. RESULTS. Resting IOP was 12.1 +/- 2.8 mm Hg and mean femoral artery pressure was 97.6 +/- 10.7 mm Hg. ERG components showed a graded effect dependent on IOP. Systematic delays in the timing of the scotopic threshold response (STR) and photopic b-wave were observed between IOPs of 30 and 40 mm Hg. Analysis of amplitudes revealed that the negative STR component (nSTR) and the photopic OPs were the most sensitive to acute IOP elevation. These components were first significantly affected at 50 mm Hg, whereas all parameters of middle and outer retinal function (scotopic P2 and P3) remained normal. The nSTR and photopic OPs declined by 50% at IOP < 61 mm Hg. The scotopic P2, OPs, and positive STR (pSTR) had intermediate sensitivity, such that they were reduced by 50% at IOPs between 61 and 66 mm Hg. Scotopic P2 amplitude, but not sensitivity, was significantly reduced by 60 mm Hg. At 60 and 70 mm Hg, the decline in P2 amplitude was not attributable to changes in photoreceptor response ( P3) amplitude or sensitivity. The least sensitive component was the scotopic a-wave (Rm(p3)) showing a 50% reduction at an IOP of 71 mm Hg. CONCLUSIONS. During acute IOP elevation, functional changes progress from the proximal to the distal retina. Alterations in ganglion-cell-related ERG potentials occurred at IOPs (30-50 mm Hg) commonly observed in rat experimental glaucoma models. Nonspecific functional changes were observed at acute IOP above 50 mm Hg, suggesting that IOP should be maintained below this level in experimental glaucoma models if selective ganglion cell injury is to be sought. Repeated IOP spikes above this level may cause permanent, nonspecific damage, perhaps via ischemic mechanisms. Thus, IOP should be monitored frequently in these models.
引用
收藏
页码:202 / 213
页数:12
相关论文
共 50 条
  • [31] Central Retinal Vessel Trunk Caliber Changes After Short-term Intraocular Pressure Elevation
    Zhang, Qi
    Lin, Cai Xia
    Yang, Hongli
    Chen, Jian Dong
    Jonas, Jost B.
    Wang, Ya Xing
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 467 - 472
  • [32] Monitoring Retinal Responses to Acute Intraocular Pressure Elevation in Rats with Visible Light Optical Coherence Tomography
    Pi, Shaohua
    Hormel, Tristan
    Wei, Xiang
    Cepurna, William
    Camino, Acner
    Guo, Yukun
    Huang, David
    Morrison, John C.
    Jia, Yali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [33] Monitoring retinal responses to acute intraocular pressure elevation in rats with visible light optical coherence tomography
    Pi, Shaohua
    Hormel, Tristan T.
    Wei, Xiang
    Cepurna, William
    Camino, Acner
    Guo, Yukun
    Huang, David
    Morrison, John
    Jia, Yali
    NEUROPHOTONICS, 2019, 6 (04)
  • [34] Retinal nerve fiber layer thickness changes after an acute increase in intraocular pressure
    Lester, M
    Tizte, P
    Mermoud, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2117 - 2122
  • [35] RETINAL BLOOD-FLOW AUTOREGULATION IN RESPONSE TO ACUTE CHANGES IN INTRAOCULAR-PRESSURE
    HALL, AL
    GRUNWALD, JE
    PILTZ, JR
    YANG, D
    DUPONT, JC
    MAGUIRE, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S114 - S114
  • [36] FLASH AND PATTERN ELECTRORETINOGRAMS DURING AND AFTER ACUTE INTRAOCULAR-PRESSURE ELEVATION IN CATS
    SILIPRANDI, R
    BUCCI, MG
    CANELLA, R
    CARMIGNOTO, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1988, 29 (04) : 558 - 565
  • [37] Intraretinal analysis of electroretinogram with K+ microelectrodes during acute intraocular pressure elevation
    Masai, H
    Hiroi, K
    Yamamoto, F
    Honda, Y
    DOCUMENTA OPHTHALMOLOGICA, 1995, 91 (02) : 129 - 139
  • [38] Retinal hemodynamics during increased intraocular pressure
    Schulte, K
    Wolf, S
    Arend, O
    Harris, A
    Henle, C
    Reim, M
    GERMAN JOURNAL OF OPHTHALMOLOGY, 1996, 5 (01) : 1 - 5
  • [39] Optical Coherence Tomography Angiography Vessel Density Changes after Acute Intraocular Pressure Elevation
    Zhang, Qi
    Jonas, Jost B.
    Wang, Qian
    Chan, Szy Yann
    Xu, Liang
    Wei, Wen Bin
    Wang, Ya Xing
    SCIENTIFIC REPORTS, 2018, 8
  • [40] The impact of ocular hemodynamics and intracranial pressure on intraocular pressure during acute gravitational changes
    Nelson, Emily S.
    Mulugeta, Lealem
    Feola, Andrew
    Raykin, Julia
    Myers, Jerry G.
    Samuels, Brian C.
    Ethier, C. Ross
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 123 (02) : 352 - 363