Increased liver stiffness by transient elastography and acoustic radiation force impulse imaging in patients with extrahepatic cholestasis

被引:4
|
作者
Darweesh, Samar K. [1 ]
Zayed, Naglaa [1 ]
Atef, Mira [1 ]
Ramzy, Eman [1 ]
Yousry, Ayman [1 ]
Musa, Sherief [1 ]
机构
[1] Cairo Univ, Hepatogastroenterol & Endem Med Dept, Fac Med, Cairo 16134, Egypt
关键词
acoustic radiation force impulse imaging; extrahepatic cholestasis; ERCP; FibroScan; liver stiffness; transient elastography; FIBROSIS;
D O I
10.1097/MEG.0000000000001881
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Transient elastography and acoustic radiation force impulse (ARFI) imaging are noninvasive tools for liver stiffness measurement (LSM), which may be influenced by cholestasis. Aim The aim of the study was to evaluate the performance of transient elastography and ARFI in extrahepatic cholestasis and correlate changes in LSM with biochemical activity. Materials and methods A total of 38 patients with extrahepatic cholestasis prospectively underwent transient elastography and ARFI. Changes in LSM by transient elastography/ARFI were evaluated after 1 week of ERCP and correlated with biochemical parameters. The optimal ARFI cutoffs according to stages of clinical interest were analyzed. Results Biliary obstruction was calcular in 21 (55.3%) and noncalcular in 17 (44.7%) (benign n = 15, malignant n = 2). After 1 week, adequate biliary drainage reduced total bilirubin from 7.7 to 2.2 mg/dL (P < 0.001) which significantly correlated with reduction of LSM by transient elastography from 12.38 +/- 6.68 kPa to 8.08 +/- 3.21 kPa (P < 0.001), and by ARFI from 1.73 +/- 0.51 m/s to 1.56 +/- 0.70 m/s (P = 0.014). The LSM percentage change showed a decrease (nonsignificant, P = 0.843) by 25.83% using transient elastography and a significant decrease (P < 0.001) by 18.42% using ARFI in the improved patients. At initial visit, transient elastography positively correlated with ARFI, bilirubin and platelets, also, transient elastography had a positive correlation with ARFI, bilirubin, alkaline phosphatase (ALP), gamma-glutamyl transpeptidase (GGT) in follow-up visit. LSM by ARFI (visit 1) negatively correlated with ALT, while in (visit 2), ARFI positively correlated with bilirubin, ALP, GGT and negatively correlated with albumin. Conclusion The increased LSM in patients with extrahepatic cholestasis is reduced after adequate biliary drainage, implying that increased values are not solely due to liver fibrosis, but due to biliary congestion leading temporarily to increased elasticity.
引用
收藏
页码:1097 / 1103
页数:7
相关论文
共 50 条
  • [31] ASSESSMENT OF LIVER FIBROSIS WITH 2-D SHEAR WAVE ELASTOGRAPHY IN COMPARISON TO TRANSIENT ELASTOGRAPHY AND ACOUSTIC RADIATION FORCE IMPULSE IMAGING IN PATIENTS WITH CHRONIC LIVER DISEASE
    Gerber, Ludmila
    Kasper, Daniela
    Fitting, Daniel
    Knop, Viola
    Vermehren, Annika
    Sprinzl, Kathrin
    Hansmann, Martin L.
    Herrmann, Eva
    Bojunga, Joerg
    Albert, Joerg
    Sarrazin, Christoph
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09): : 2350 - 2359
  • [32] Evaluation of Acoustic Radiation Force Impulse Elastography for Liver Tumors
    Chiba, Mitsuru
    Goto, Takashi
    Miura, Kouichi
    Ohshima, Shigetoshi
    Shibuya, Tomomi
    Sato, Wataru
    Dohmen, Takahiro
    Yamada, Ikuhiro
    Kamada, Kentaro
    Kanata, Ryo
    Sakai, Toshitaka
    Sugimoto, Yuko
    Ohnishi, Hirohide
    GASTROENTEROLOGY, 2012, 142 (05) : S1004 - S1004
  • [33] Liver stiffness measured by acoustic radiation force impulse elastography reflects the severity of liver damage and prognosis in patients with acute liver failure
    Kuroda, Hidekatsu
    Kakisaka, Keisuke
    Oikawa, Takayoshi
    Onodera, Mio
    Miyamoto, Yasuhiro
    Sawara, Kei
    Endo, Ryujin
    Suzuki, Kazuyuki
    Takikawa, Yasuhiro
    HEPATOLOGY RESEARCH, 2015, 45 (05) : 571 - 577
  • [34] Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan®
    Hirotoshi Ebinuma
    Hidetsugu Saito
    Mina Komuta
    Keisuke Ojiro
    Kanji Wakabayashi
    Shingo Usui
    Po-sung Chu
    Rumiko Umeda
    Yuka Ishibashi
    Tetsurou Takayama
    Masahiro Kikuchi
    Nobuhiro Nakamoto
    Yoshiyuki Yamagishi
    Takanori Kanai
    Kiyoshi Ohkuma
    Michiie Sakamoto
    Toshifumi Hibi
    Journal of Gastroenterology, 2011, 46 : 1238 - 1248
  • [35] Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan®
    Ebinuma, Hirotoshi
    Saito, Hidetsugu
    Komuta, Mina
    Ojiro, Keisuke
    Wakabayashi, Kanji
    Usui, Shingo
    Chu, Po-sung
    Umeda, Rumiko
    Ishibashi, Yuka
    Takayama, Tetsurou
    Kikuchi, Masahiro
    Nakamoto, Nobuhiro
    Yamagishi, Yoshiyuki
    Kanai, Takanori
    Ohkuma, Kiyoshi
    Sakamoto, Michiie
    Hibi, Toshifumi
    JOURNAL OF GASTROENTEROLOGY, 2011, 46 (10) : 1238 - 1248
  • [36] The usefulness of transient elastography, acoustic-radiation-force impulse elastography, and real-time elastography for the evaluation of liver fibrosis
    Chung, Jong Ho
    Ahn, Hyung Su
    Kim, Sang Gyune
    Lee, Yun Nah
    Kim, Young Seok
    Jeong, Soung Won
    Jang, Jae Young
    Lee, Sae Hwan
    Kim, Hong Soo
    Kim, Boo Sung
    CLINICAL AND MOLECULAR HEPATOLOGY, 2013, 19 (02) : 156 - 164
  • [37] The usefulness of spleen stiffness evaluated by Acoustic Radiation Force Impulse (ARFI) elastography for assessing liver fibrosis
    Bota, Simona
    Sporea, Ioan
    Tascau, Oana Gradinaru
    Popescu, Alina
    Sirli, Roxana
    Danila, Mirela
    HEPATOLOGY, 2014, 60 : 441A - 441A
  • [38] Acoustic radiation force impulse imaging—normal values of liver stiffness in healthy children
    Sylviane Hanquinet
    Delphine Courvoisier
    Aikaterini Kanavaki
    Amira Dhouib
    Mehrak Anooshiravani
    Pediatric Radiology, 2013, 43 : 539 - 544
  • [39] COMPARISON OF ACOUSTIC RADIATION FORCE IMPULSE IMAGING AND TRANSIENT ELASTOGRAPHY FOR NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS B
    Zhang, Dakun
    Chen, Min
    Wang, Ruifang
    Liu, Yang
    Zhang, Dedong
    Liu, Liping
    Zhou, Guangde
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 7 - 14
  • [40] Acoustic Radiation Force Impulse Elastography: Tissue Stiffness Measurement in Limo Lymonecema
    Chan, Wen-Hui
    Huang, Yen-Ling
    Lin, Chieh
    Lin, Chia-Yu
    Cheng, Ming-Huei
    Chu, Sung-Yu
    RADIOLOGY, 2018, 289 (03) : 759 - 765