Purpose To evaluate the impact of reducing B-scan frame-sampling density on retinal thickness measurements using spectral domain optical coherence tomography (SD-OCT) in eyes with diabetic macular edema (DME). Methods We retrospectively collected OCT data for 64 eyes of 43 patients undergoing imaging for DME using the Cirrus HD-OCT 512 x 128 macular cube protocol. For each case, raw OCT data were imported into the 3D-OCTOR software, and retinal thickness maps were generated using all 128 B-scans and for lower densities of B-scans ranging from every other scan to only four scans (every 30-s B-scan). Maps were generated before and after manual correction of retinal boundary segmentation errors. The foveal central subfield (FCS) and total macular volume (TMV) values were used to compare thickness maps of varying densities. Results The mean difference in FCS retinal thickness and TMV increased as the B-scan density was reduced, particularly when the density was reduced to fewer than 16 B-scans over 6 mm. At a density of 16 B-scans, the mean absolute difference in FCS thickness was 2.43 mu m (0.79%), with a maximum of 10.1 mu m (4.09%). At this density, the mean difference in TMV was 0.012 mm(3) (0.13%), with a maximum difference of 0.04 mm(3) (0.47%). Manual correction of OCT segmentation errors resulted in a difference in FCS thickness of >= 10 mu m in only 12.5% of cases, with a maximum difference of 115.7 mu m. Conclusion A minimum of 16 equally spaced B-scans appear necessary to generate retinal thickness measurements similar to those produced using all 128 B-scans in eyes with DME. Manual correction of segmentation errors appeared to have a clinically meaningful effect in a small minority of cases. These results may have implications for the design of SD-OCT imaging and grading protocols in clinical trials of DME, particularly when using multiple SD-OCT instruments that acquire varying numbers of B-scans. Eye (2011) 25, 1347-1355; doi:10.1038/eye.2011.173; published online 15 July 2011
引用
收藏
页码:1347 / 1355
页数:9
相关论文
共 50 条
  • [21] Subfoveal choroidal thickness in diabetic macular edema
    Mohamed, Dalia Mohamed Fawzy
    Hassan, Nihal Adel
    Osman, Amr Abdellatif
    Osman, Moataz Hamed
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 921 - 925
  • [22] Overnight thickness variation in diabetic macular edema
    Larsen, M
    Wang, M
    Sander, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2313 - 2316
  • [23] Macular thickness in diabetic eyes without clinical macular edema
    Zamora, M. Garcia
    Moreno, J. A. Montero
    Uruena, C. Gonzalez
    Caballero, E. Frances
    Fernandez-Munoz, M.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [24] INITIAL MACULAR THICKNESS AND RESPONSE TO TREATMENT IN DIABETIC MACULAR EDEMA
    Soheilian, Masoud
    Ramezani, Alireza
    Yaseri, Mehdi
    Mirdehghan, Seyed Ali
    Obudi, Arash
    Bijanzadeh, Bijan
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (08): : 1564 - 1573
  • [25] Impact of B-Scan Density on Spectral Domain OCT Retinal Thickness Measurements
    Sadda, S. R.
    Pappuru, R. R.
    Stetson, P. F.
    Keane, P. A.
    Walsh, A. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [26] Automated segmentation of diabetic macular edema in OCT B-scan images based on RCU-Net
    Wu, Jun
    Zhang, Yaxin
    Xiao, Zhitao
    Zhang, Fang
    Geng, Lei
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (01) : 299 - 311
  • [27] Choroidal thickness comparison of non edematous and edematous macular areas in patients with diabetic macular edema using EDI-OCT
    Pereira, Felipe
    Fontanelli, Stephanie
    Novais, Eduardo Amorim
    Regatieri, Caio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [28] Sensitivity and Specificity of HRT and OCT to Detect Diabetic Macular Edema
    Suresh, Subramaniam
    Zunaina, Embong
    Shatriah, Ismail
    Azriani, Ab-Rahman
    JOURNAL OF DIABETES & METABOLISM, 2012, 3
  • [29] Joint Diabetic Macular Edema Segmentation and Characterization in OCT Images
    Joaquim de Moura
    Gabriela Samagaio
    Jorge Novo
    Pablo Almuina
    María Isabel Fernández
    Marcos Ortega
    Journal of Digital Imaging, 2020, 33 : 1335 - 1351
  • [30] OCT Biomarkers and Visual Acuity in the Treatment of Diabetic Macular Edema
    Takahashi, Hiroyuki
    Abu-qamar, Omar
    Girgis, Jessica M.
    Call, Catherine
    Ghide, Benhur H.
    Marmalidou, Anna
    Liu, Yingna
    Waheed, Nadia K.
    OPHTHALMOLOGY RETINA, 2024, 8 (07): : 725 - 727