Amperometric glucose-sensing electrode based on colloidal gold/glucose oxidase-modified glassy carbon

被引:0
|
作者
Yabuki, S
Mizutani, F
机构
[1] National Institute of Bioscience and Human-Technology, Tsukuba, Ibaraki, 305
来源
DENKI KAGAKU | 1996年 / 64卷 / 12期
关键词
colloidal gold particle; glucose oxidase; glucose sensing electrode; complex;
D O I
10.5796/kogyobutsurikagaku.64.1256
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
[No abstract available]
引用
收藏
页码:1256 / 1258
页数:3
相关论文
共 50 条
  • [21] Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    Liu, SQ
    Ju, HX
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (03): : 177 - 183
  • [22] GLUCOSE OXIDASE-MODIFIED SNO2 ELECTRODE AS ELECTROCHEMICAL GLUCOSE SENSOR
    WATANABE, T
    OKAWA, Y
    TSUZUKI, H
    YOSHIDA, S
    NIHEI, Y
    [J]. CHEMISTRY LETTERS, 1988, (07) : 1183 - 1186
  • [23] Amperometric glucose sensor fabricated by combining glucose oxidase micelle membrane and aminated glassy carbon electrode
    Wang, X.
    Uchiyama, S.
    [J]. ANALYTICAL LETTERS, 2008, 41 (07) : 1173 - 1183
  • [24] Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode
    Tang, H
    Chen, JH
    Yao, SZ
    Nie, LH
    Deng, GH
    Kuang, YF
    [J]. ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 89 - 97
  • [25] Amperometric glucose biosensor based on the deposition of copper and glucose oxidase onto glassy carbon transducer
    Rodriguez, MC
    Rivas, GA
    [J]. ANALYTICAL LETTERS, 2000, 33 (12) : 2373 - 2389
  • [26] Design of an Amperometric Glucose Biosensor Based on Glucose Oxidase/Arginated-Fe3O4/Glassy Carbon Electrode
    Krishna, Rahul
    Chandra, Sudeshna
    Bardhan, Neelkanth
    Salimian, Maryam
    Yang, Y. Y.
    Titus, Elby
    Gracio, Jose
    Bahadur, Dhirendra
    [J]. SCIENCE OF ADVANCED MATERIALS, 2013, 5 (04) : 333 - 340
  • [27] AN AMPEROMETRIC GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE ADSORBED ON A NONPOROUS CARBON ELECTRODE
    GORTON, L
    SCHELLER, F
    JOHANSSON, G
    [J]. STUDIA BIOPHYSICA, 1985, 109 (2-3): : 199 - 204
  • [28] Glucose oxidase-modified carbon-felt-reactor coupled with peroxidase-modified carbon-felt-detector for amperometric flow determination of glucose
    Wang, Yue
    Hasebe, Yasushi
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (03): : 432 - 439
  • [29] Direct electrochemistry of glucose oxidase and glucose biosensing on a hydroxyl fullerenes modified glassy carbon electrode
    Gao, Yun-Fei
    Yang, Tian
    Yang, Xiao-Lu
    Zhang, Yu-Shuai
    Xiao, Bao-Lin
    Hong, Jun
    Sheibani, Nader
    Ghourchian, Hedayatollah
    Hong, Tao
    Moosavi-Movahedi, Ali Akbar
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 60 : 30 - 34
  • [30] A Glassy Carbon Electrode Modified with Glucose Oxidase and MWCNT-Palladium Nanoparticles for the Determination of Glucose
    You, Jung-Min
    Jeon, Seungwon
    [J]. ELECTROANALYSIS, 2011, 23 (09) : 2103 - 2108