Amperometric determination of sympathomimetic drugs by flow injection analysis with a metallic copper electrode

被引:6
|
作者
Chicharro, M [1 ]
Zapardiel, A [1 ]
Bermejo, E [1 ]
Pérez, JA [1 ]
Hernández, L [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
copper electrode; copper; flow injection analysis; sympathomimetic drugs; norephedrine; ephedrine;
D O I
10.1016/S0003-2670(98)00656-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and determination of sympathomimetic drugs in flow injection systems with an amperometric method based on a metallic copper wire electrode is described. The copper electrode is shown to give sensitive response toward sympathomimetic drugs, especially for norephedrine in flow injection analysis. The copper electrodes require no pretreatment except polishing before use. Furthermore, the copper working electrode shows stable response in such a system and the relative standard deviation is only 4.6% for 30 consecutive norephedrine injections at a 0.15 mM level. A detection limit of 10(-9) mol (0.15 mu g norephedrine) for a sample loop of 0.1 mi was obtained at a fixed potential of +0.6 V (vs. Ag/AgCl) in NaOH 0.1 M and a Bow rate of 2.0 ml/min. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [41] Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
    Jan Mika
    Josino C. Moreira
    Andrea Nemeckova
    Jiri Zima
    Jiri Barek
    Hana Dejmkova
    [J]. Monatshefte für Chemie - Chemical Monthly, 2015, 146 : 1211 - 1215
  • [42] Amperometric determination of chemical oxygen demand with flow injection analysis using F-PbO2 modified electrode
    Li, JQ
    Li, LP
    Zheng, L
    Xian, YZ
    Ai, SY
    Jin, LT
    [J]. ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) : 199 - 204
  • [43] Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
    Mika, Jan
    Moreira, Josino C.
    Nemeckova, Andrea
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    [J]. MONATSHEFTE FUR CHEMIE, 2015, 146 (08): : 1211 - 1215
  • [44] Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    [J]. ANALYST, 1997, 122 (09) : 985 - 989
  • [45] Amperometric determination of thiourea in alkaline media on a copper oxide–copper electrode
    F. Manea
    C. Radovan
    J. Schoonman
    [J]. Journal of Applied Electrochemistry, 2006, 36 : 1075 - 1081
  • [46] Flow-Injection Pulsed-Amperometric Determination of Free Glycerol in Biodiesel at a Gold Electrode
    Barbosa, Tatielli G. G.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    [J]. ELECTROANALYSIS, 2012, 24 (05) : 1160 - 1163
  • [47] Potentiometric detection of aliphatic amines by flow injection analysis and ion-interaction chromatography with a metallic copper electrode
    Chen, ZL
    Alexander, PW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (02) : 227 - 233
  • [48] A poly(vinyl choloride) graphite composite electrode for flow-injection amperometric determination of antioxidants
    Luque, M
    Ríos, A
    Valcárcel, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) : 217 - 223
  • [49] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [50] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF INSULIN BASED UPON ITS OXIDATION AT A MODIFIED ELECTRODE
    COX, JA
    GRAY, TJ
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (21) : 2462 - 2464