Amperometric determination of sympathomimetic drugs by flow injection analysis with a metallic copper electrode

被引:6
|
作者
Chicharro, M [1 ]
Zapardiel, A [1 ]
Bermejo, E [1 ]
Pérez, JA [1 ]
Hernández, L [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
copper electrode; copper; flow injection analysis; sympathomimetic drugs; norephedrine; ephedrine;
D O I
10.1016/S0003-2670(98)00656-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and determination of sympathomimetic drugs in flow injection systems with an amperometric method based on a metallic copper wire electrode is described. The copper electrode is shown to give sensitive response toward sympathomimetic drugs, especially for norephedrine in flow injection analysis. The copper electrodes require no pretreatment except polishing before use. Furthermore, the copper working electrode shows stable response in such a system and the relative standard deviation is only 4.6% for 30 consecutive norephedrine injections at a 0.15 mM level. A detection limit of 10(-9) mol (0.15 mu g norephedrine) for a sample loop of 0.1 mi was obtained at a fixed potential of +0.6 V (vs. Ag/AgCl) in NaOH 0.1 M and a Bow rate of 2.0 ml/min. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] Amperometric determination of acetylsalicylic acid in drugs by batch injection analysis at a copper electrode in alkaline solutions
    Quintino, MDM
    Corbo, D
    Bertotti, M
    Angnes, L
    [J]. TALANTA, 2002, 58 (05) : 943 - 949
  • [2] Flow-through amperometric determination of ampicillin using a copper electrode in a batch injection analysis system
    Veloso, William Barros
    Correa Ribeiro, Geyse Adriana
    da Rocha, Claudia Quintino
    Tanaka, Auro Atsushi
    da Silva, Iranaldo Santos
    Ferreira Dantas, Luiza Maria
    [J]. MEASUREMENT, 2020, 155 (155)
  • [3] Flow injection analysis of some phenolic sympathomimetic drugs
    El-Gendy, AE
    [J]. ANALYTICAL LETTERS, 2000, 33 (14) : 2927 - 2938
  • [4] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF SUGARS USING A METALLIC COPPER ELECTRODE
    ALEXANDER, PW
    HADDAD, PR
    TROJANOWICZ, M
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (16): : 1953 - 1978
  • [5] Flow injection analysis of free glycerol in biodiesel using a copper electrode as an amperometric detector
    Maruta, Aleksander H.
    Paixao, Thiago R. L. C.
    [J]. FUEL, 2012, 91 (01) : 187 - 191
  • [6] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CHLORINE AT A GOLD ELECTRODE
    TSAOUSIS, AN
    HUBER, CO
    [J]. ANALYTICA CHIMICA ACTA, 1985, 178 (02) : 319 - 323
  • [7] Voltammetric and flow injection amperometric determination of cysteine at a glassy carbon electrode in the presence of Copper(II) ions
    Dursun, Z
    Sahbaz, I
    Ertas, FN
    Nisli, G
    [J]. TURKISH JOURNAL OF CHEMISTRY, 2003, 27 (04) : 513 - 519
  • [8] AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE
    ALEXANDER, PW
    AKAPONGKUL, U
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 103 - 109
  • [9] FLOW-INJECTION DETERMINATION OF NITRITE BY AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE
    COX, JA
    KULKARNI, KR
    [J]. ANALYST, 1986, 111 (10) : 1219 - 1220
  • [10] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CYANIDE ON A MODIFIED SILVER ELECTRODE
    NIKOLIC, SD
    MILOSAVLJEVIC, EB
    HENDRIX, JL
    NELSON, JH
    [J]. ANALYST, 1992, 117 (01) : 47 - 50