A collision prediction framework for noncoplanar radiotherapy planning and delivery

被引:8
|
作者
Islam, Naveed [1 ,2 ]
Kilian-Meneghin, Josh [1 ,2 ]
deBoer, Steven [1 ,2 ]
Podgorsak, Matthew [1 ,2 ]
机构
[1] SUNY Buffalo, Buffalo, NY 14260 USA
[2] Roswell Park Canc Inst, Buffalo, NY 14263 USA
来源
关键词
collision prediction; noncoplanar radiation therapy; patient safety; treatment planning; COUCH POSITION COMBINATIONS; BODY RADIATION-THERAPY; INDICATOR CHARTS; AVOIDANCE; IMRT; OPTIMIZATION; SIMULATION; COPLANAR; HEAD; ARC;
D O I
10.1002/acm2.12920
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Noncoplanar radiotherapy can provide significant dosimetric benefits. However, clinical implementation of such techniques is not fully realized, partially due to the absence of a collision prediction tool integrated into the clinical workflow. In this work, the feasibility of developing a collision prediction system (CPS) suitable for integration into clinical practice has been investigated. Methods The CPS is based on a geometric model of the Linear Accelerator (Linac), and patient morphology acquired at the simulator using a combination of the planning CT scan and 3-D vision camera (Microsoft, Kinect) data. Physical dimensions of Linac components were taken to construct a geometric model. The Linac components include the treatment couch, gantry, and imaging devices. The treatment couch coordinates were determined based on a correspondence among the CT couch top, Linac couch, and the treatment isocenter location. A collision is predicted based on dot products between vectors denoting points in Linac components and patient morphology. Collision test cases were simulated with the CPS and experimentally verified using ArcCheck and Rando phantoms to simulate a patient. Results For 111 collision test cases, the sensitivity and specificity of the CPS model were calculated to be 0.95 and 1.00, respectively. The CPS predicted collision states that left conservative margins, as designed, relative to actual collision locations. The average difference between the predicted and measured collision states was 2.3 cm for lateral couch movements. The predicted couch rotational position for a collision between the gantry and a patient analog differed from actual values on average by 3.8 degrees. The magnitude of these differences is sufficient to account for interfractional patient positioning variations during treatment. Conclusion The feasibility of developing a CPS using geometric models and standard vector algebra has been investigated. This study outlines a framework for potential clinical implementation of a CPS for noncoplanar radiotherapy.
引用
收藏
页码:92 / 106
页数:15
相关论文
共 50 条
  • [41] A modulated electron radiotherapy program: Planning, optimization, delivery and verification
    Klein, E. E.
    Surucu, M.
    Mamalui-Hunter, M.
    Mansur, D. B.
    Low, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S517 - S517
  • [42] Advances in treatment planning, optimization and delivery for radiotherapy of breast cancer
    Dumane, Vishruta
    Ohri, Nisha
    Choi, Jehee Isabelle
    Chhabra, Arpit
    Lin, Haibo
    FRONTIERS IN ONCOLOGY, 2024, 13
  • [43] Results of a National Survey of Radiotherapy Planning and Delivery in the UK in 2007
    Jefferies, S.
    Taylor, A.
    Reznek, R.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 204 - 217
  • [44] Noncoplanar RapidArc for Stereotactic Radiotherapy (SBRT) for Peripheral Lung Tumors
    Ding, M.
    Zollinger, W.
    Heard, D.
    Ebeling, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S865 - S866
  • [45] Fully automated noncoplanar radiation therapy treatment planning
    Huang, Charles
    Yang, Yong
    Xing, Lei
    MEDICAL PHYSICS, 2021, 48 (11) : 7439 - 7449
  • [46] Impact of patient positioning uncertainty in noncoplanar intracranial stereotactic radiotherapy
    Tanaka, Yoshihiro
    Oita, Masataka
    Inomata, Shinichiro
    Fuse, Toshiaki
    Akino, Yuichi
    Shimomura, Kohei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 89 - 97
  • [47] COMPENSATION IN 3-DIMENSIONAL NONCOPLANAR TREATMENT PLANNING
    KUTCHER, GJ
    BURMAN, C
    MOHAN, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01): : 127 - 134
  • [48] Integrating knowledge-based planning and noncoplanar oblique VMAT arcs: A study of dose to the heart and immune cells in thoracic radiotherapy
    Diedrich, Brennan
    Roper, Justin
    Hopkins, Benjamin
    Tian, Sibo
    Momin, Shadab
    Schreibmann, Eduard
    Kesarwala, Aparna H.
    Luca, Kirk
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2025, 33
  • [49] A motion prediction confidence estimation framework for prediction-based radiotherapy gating
    Ginn, John S.
    Low, Daniel A.
    Lamb, James M.
    Ruan, Dan
    MEDICAL PHYSICS, 2020, 47 (08) : 3297 - 3304
  • [50] A tool for collision prediction in linac-based intracranial radiosurgery planning
    Felefly, T.
    Azoury, F.
    El Khoury, C.
    Barouky, J.
    Farah, N.
    Sayah, R.
    Khater, N.
    Nasr, D. Nehme
    Nasr, E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S776 - S777