Detection of L-band electron paramagnetic resonance in the DPPH molecule using impedance measurements

被引:4
|
作者
Chaudhuri, Ushnish [1 ]
Mahendiran, R. [1 ]
机构
[1] Natl Univ Singapore, Dept Phys, 2 Sci Dr 3, Singapore 117551, Singapore
关键词
SPIN-RESONANCE; EPR SPECTROSCOPY; DISPERSION; MAGNETOIMPEDANCE; SPECTRA;
D O I
10.1039/d0ra03285a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Detection of electron paramagnetic resonance (EPR) using a microwave cavity resonating at a fixed frequency (between 9 and 10 GHz) remains the most popular method to date. Here, we report a cavity-less technique which makes use of only an impedance analyzer and a copper strip coil to detect L-band EPR (f = 1-3 GHz) in the standard EPR marker 2,2-diphenyl-1-picrylhydrazyl (DPPH). Our method relies on measuring the magnetoimpedance (MI) response of DPPH through a copper strip coil that encloses DPPH. In contrast to commercial EPR which measures only the field derivative of power absorption, our method enables us to deduce both absorption and dispersion. Changes in resistance (R) and reactance (X) of the copper strip while sweeping an external dc magnetic field, were measured for different frequencies (f = 0.9 to 2.5 GHz) of radio frequency current in the coil. R exhibits a sharp peak at a critical value of the dc magnetic field, which is identified as the resonance field and X shows a dispersion at the same frequency. The data were analyzed to obtain line width and resonance field parameters. The resonance field increased linearly with frequency and the obtained Lande g factor of 1.999 +/- 0.0197 is close to the accepted value of 2.0036, measured in the X-band. The simplicity of this technique can be exploited to study paramagnetic centers in catalysis and other materials.
引用
收藏
页码:17311 / 17316
页数:6
相关论文
共 50 条
  • [41] Accurate L-Band Dielectric Constant Measurements of Seawater
    Lang, Roger H.
    Tarkocin, Yalcin
    Utku, Cuneyt
    Le Vine, David
    2008 MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT, 2008, : 204 - +
  • [42] Accurate measurements in the L-band require added features
    Sperrin, G.
    Laser Focus World, 2001, 37 (6 SUPPL.):
  • [43] Strongly driven electron spins using a Ku band stripline electron paramagnetic resonance resonator
    Yap, Yung Szen
    Yamamoto, Hiroshi
    Tabuchi, Yutaka
    Negoro, Makoto
    Kagawa, Akinori
    Kitagawa, Masahiro
    JOURNAL OF MAGNETIC RESONANCE, 2013, 232 : 62 - 67
  • [44] Nitrogen oxide and its detection in biosystems using electron paramagnetic resonance
    Vanin, AF
    USPEKHI FIZICHESKIKH NAUK, 2000, 170 (04): : 455 - 458
  • [45] Design of an Electron Optics System for L-Band Klystron
    Yang, Xiudong
    Zhang, Rui
    Zhang, Zhiqiang
    2019 INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2019,
  • [46] L-BAND FILTER MADE BY ELECTRON-BEAM
    不详
    ELECTRONICS, 1974, 47 (01): : 42 - 42
  • [47] Paramagnetic resonance and detection of a single electron spin
    Buchachenko, AL
    Dalidchik, FI
    Kovalevskii, SA
    Shub, BR
    USPEKHI KHIMII, 2001, 70 (07) : 611 - 618
  • [48] Paramagnetic resonance and detection of a single electron spin
    Buchachenko, A.L.
    Dalidchik, F.I.
    Kovalevskii, S.A.
    Shub, B.R.
    Russian Chemical Reviews, 2001, 70 (07) : 535 - 541
  • [49] THERMOACOUSTIC DETECTION OF ELECTRON-PARAMAGNETIC RESONANCE
    MELCHER, RL
    APPLIED PHYSICS LETTERS, 1980, 37 (10) : 895 - 897
  • [50] Electron paramagnetic resonance detection of irradiated foodstuffs
    Raffi, J
    Stocker, P
    APPLIED MAGNETIC RESONANCE, 1996, 10 (1-3) : 357 - 373