The charge trapping effect in compound semiconductor gamma-ray detectors in the presence of a uniform electric held is commonly described by Hecht's relation. However, Hecht's relation ignores the geometrical spread of charge carriers caused by the finite range of primary and secondary electrons (6-rays) in the detector. In this paper, a method based on the Shockley-Ramo theorem is developed to calculate 7-ray induced charge pulses by taking into account the charge-trapping effect associated with the geometrical spread of charge carriers. The method is then used to calculate the response of a planar CdTe detector to energetic gamma-rays by which the influence of electron track lengths on the y-ray response of the detectors is clearly shown. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] Collisional, radiative and total electron interaction in compound semiconductor detectors and solid state nuclear track detectors: Effective atomic number and electron density
    Kurudirek, Murat
    Kurudirek, Sinem V.
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 54 - 58
  • [2] Analytic Response Functions in Compound Semiconductor Detectors
    Yun, Seungman
    Kim, Ho Kyung
    Youn, Hanbean
    Tanguay, Jesse
    Cunningham, Ian A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2618 - 2624
  • [3] THE INFLUENCE OF PHANTOMS ON THE RESPONSE OF ETCHED TRACK DETECTORS
    HOLLNAGEL, R
    JAHR, R
    SIEBERT, BRL
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 25 - 29
  • [4] Response of cellulose nitrate track detectors to electron doses
    Segovia, N
    Lopez-Valdivia, H
    Moreno, A
    Vazquez-Polo, G
    Santamaria, T
    Aranda, P
    Hernandez, A
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 487 - 490
  • [5] Response of cellulose nitrate track detectors to electron doses
    Segovia, N.
    Lopez-Valdivia, H.
    Moreno, A.
    Vazquez-Polo, G.
    Santamaria, T.
    Aranda, P.
    Hernandez, A.
    Radiation Measurements, 1999, 31 (01) : 487 - 490
  • [6] CALCULATED GAMMA RAY RESPONSE CHARACTERISTICS OF SEMICONDUCTOR DETECTORS
    WAINIO, KM
    KNOLL, GF
    NUCLEAR INSTRUMENTS & METHODS, 1966, 44 (02): : 213 - &
  • [7] Future space applications of compound semiconductor X-ray detectors
    Bavdaz, M
    Peacock, A
    Owens, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 123 - 131
  • [9] Compound semiconductor radiation detectors
    Owens, A
    Peacock, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 18 - 37
  • [10] IMPACT OF SEMICONDUCTOR DETECTORS ON GAMMA-RAY AND ELECTRON SPECTROSCOPY
    HOLLANDER, JM
    NUCLEAR INSTRUMENTS & METHODS, 1966, 43 (01): : 65 - +