Relative pre-calibration of the ALICE electromagnetic calorimeter EMCAL

被引:0
|
作者
Faivre, J. [1 ]
机构
[1] Univ Grenoble 1, LPSC, CNRS IN2P3, Inst Polytech Grenoble, Grenoble, France
关键词
D O I
10.1088/1742-6596/293/1/012046
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Several experiments showed that calorimetry is an essential tool for the Quark-Gluon Plasma study. ALICE, on the LHC collider, therefore integrated two electromagnetic calorimeters in its design. We will explain how the relative pre-calibration of one of them, the EMCAL, is performed thanks to cosmic muons, through an iterative procedure which consists in varying the high-voltage associated to each channel to ajust its gain. After 3 iterations of high-voltage tuning, of which each requires a day of data-taking, the dispersion (RMS over mean) of the channel amplitude of the response to a muon at minimum ionisation is found to be less than 2 %. We also show that more iterations allow to lower this value down to 1 %.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Calibration of the electromagnetic calorimeter of CMS
    Massironi, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2010, 33 (06):
  • [22] The ALICE electromagnetic calorimeter high level triggers
    Ronchetti, F.
    Blanco, F.
    Figueredo, M.
    Knospe, A. G.
    Xaplanteris, L.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [23] Radiometric pre-Calibration of Alsat-1 Camera
    Rachedi, A.
    Belkacemi, K.
    Benbouzid, A. B.
    Laidi, K.
    Belghoraf, A.
    Sweeting, Martin N.
    RAST 2009: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SPACE TECHNOLOGIES, 2009, : 361 - 366
  • [24] Improved pre-calibration bombing targeting method for moving targets
    Jing X.
    Hou M.
    Xiao S.
    Yu X.
    Yang L.
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2019, 41 (04): : 876 - 882
  • [25] Calibration of MPD electromagnetic calorimeter with muons
    Semenov, A. Yu.
    Semenova, I. A.
    Bhattacharjee, M.
    Durum, A.
    Krechetov, Yu.
    Kulikov, V.
    Mamonov, I.
    Martemianov, M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05):
  • [26] Calibration strategy of CMS electromagnetic calorimeter
    Paramatti, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 22 - 23
  • [27] Commissioning and calibration of the electromagnetic calorimeter of ATLAS
    Banfi, D.
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA B-GENERAL PHYSICS RELATIVITY ASTRONOMY AND MATHEMATICAL PHYSICS AND METHODS, 2008, 123 (6-7): : 723 - 725
  • [28] Calibration of the electromagnetic calorimeter of the CMS experiment
    Tabarelli de Fatis, T.
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [29] Calibration of the CMS Electromagnetic Calorimeter at the LHC
    Leslie, D. E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1196 - 1198
  • [30] CMS electromagnetic calorimeter calibration and alignment
    Wamorkar, Tanvi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 121 - 123