Rapid detection of bacterial cell from whole blood: Integration of DNA sample preparation into single micro-PCR chip

被引:28
|
作者
Hwang, Kyu-Youn [1 ,2 ]
Jeong, Sung-Young [1 ]
Kim, Young-Rok [3 ,4 ]
Namkoong, Kak [1 ]
Lim, Hee-Kyun [1 ,5 ]
Chung, Won-Seok [1 ]
Kim, Joon-Ho [1 ]
Huh, Nam [1 ]
机构
[1] Samsung Elect Co, Bio & Hlth Lab, SAIT, Yongin 446712, Gyeonggi Do, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 151742, South Korea
[3] Kyung Hee Univ, Inst Life Sci & Resources, Yongin 446701, Gyeonggi Do, South Korea
[4] Kyung Hee Univ, Dept Food Sci & Biotechnol, Yongin 446701, Gyeonggi Do, South Korea
[5] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Coll Life Sci & Bioengn, Taejon 305701, South Korea
关键词
Micro-PCR; DNA sample preparation; Integration; Bacteria; POLYMERASE-CHAIN-REACTION; SILICON-GLASS CHIPS; MICROFLUIDIC DEVICES; PURIFICATION; AMPLIFICATION; SYSTEM;
D O I
10.1016/j.snb.2009.11.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel bacterial cell detection method from blood samples has been developed for molecular diagnostics. Functional integration of DNA sample preparation into polymerase chain reaction (PCR) chip enabled detection of pathogenic bacterial cells in a single microchip. Surface-modified micropillars possessing affinity for bacterial cells were fabricated inside a PCR chip, and reaction conditions were optimized to render the microchip with high surface-to-volume ratio PCR-compatible. After bacterial cells were captured on the micropillars from whole blood and PCR inhibitors were washed out. PCR mixture was injected to allow real-time amplification of DNA extracted from the isolated cells. Cell enrichment effect produced by volume reduction from large initial sample to small micro-PCR chip chamber led to increased detection sensitivity. Moreover, the developed method from sample preparation to detection of bacterial cells from whole blood took less than 1 h. These results demonstrated that the surface-modified pillar-packed microchip would be a practical approach for integration into Lab-On-a-Chip (LOC) to enable point-of-care genetic analysis. Crown Copyright (C) 2009 Published by Elsevier BM. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [41] Optimized protocol for the extraction of RNA and DNA from frozen whole blood sample stored in a single EDTA tube
    Yamagata, Hirotaka
    Kobayashi, Ayumi
    Tsunedomi, Ryouichi
    Seki, Tomoe
    Kobayashi, Masaaki
    Hagiwara, Kosuke
    Chen, Chong
    Uchida, Shusaku
    Okada, Go
    Fuchikami, Manabu
    Kamishikiryo, Toshiharu
    Iga, Jun-ichi
    Numata, Shusuke
    Kinoshita, Makoto
    Kato, Takahiro A.
    Hashimoto, Ryota
    Nagano, Hiroaki
    Okamoto, Yasumasa
    Ueno, Shuichi
    Ohmori, Tetsuro
    Nakagawa, Shin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [42] Optimized protocol for the extraction of RNA and DNA from frozen whole blood sample stored in a single EDTA tube
    Hirotaka Yamagata
    Ayumi Kobayashi
    Ryouichi Tsunedomi
    Tomoe Seki
    Masaaki Kobayashi
    Kosuke Hagiwara
    Chong Chen
    Shusaku Uchida
    Go Okada
    Manabu Fuchikami
    Toshiharu Kamishikiryo
    Jun-ichi Iga
    Shusuke Numata
    Makoto Kinoshita
    Takahiro A. Kato
    Ryota Hashimoto
    Hiroaki Nagano
    Yasumasa Okamoto
    Shuichi Ueno
    Tetsuro Ohmori
    Shin Nakagawa
    Scientific Reports, 11
  • [43] Rapid and fully automated bacterial pathogen detection on a centrifugal-microfluidic LabDisk using highly sensitive nested PCR with integrated sample preparation
    Czilwik, G.
    Messinger, T.
    Strohmeier, O.
    Wadle, S.
    von Stetten, F.
    Paust, N.
    Roth, G.
    Zengerle, R.
    Saarinen, P.
    Niittymaki, J.
    McAllister, K.
    Sheils, O.
    O'Leary, J.
    Mark, D.
    LAB ON A CHIP, 2015, 15 (18) : 3749 - 3759
  • [44] Rapid, Point-of-Care Extraction of Human Immunodeficiency Virus Type 1 Proviral DNA from Whole Blood for Detection by Real-Time PCR
    Jangam, Sujit R.
    Yamada, Douglas H.
    McFall, Sally M.
    Kelso, David M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (08) : 2363 - 2368
  • [45] Mathematical modeling of functionalized-microsphere based assays for rapid DNA detection: From sample preparation to results
    Louw, Tobias M.
    Gomez-Duarte, Oscar G.
    Subramanian, Anuradha
    Viljoen, Hendrik J.
    BIOCHEMICAL ENGINEERING JOURNAL, 2014, 88 : 50 - 60
  • [46] Lab-on-a-chip platforms from sample preparation via continuous-flow PCR to an ultrafast detection of B-agents
    Klemm, Richard
    Becker, Holger
    Hlawatsch, Nadine
    Gaertner, Claudia
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY IX, 2012, 8367
  • [47] RAPID GENOTYPING OF GENETICALLY MODIFIED LABORATORY ANIMALS FROM WHOLE BLOOD SAMPLES WITHOUT DNA PREPARATION SHORT COMMUNICATION
    Horvath, A.
    Santha, P.
    Horvath, V.
    Torok, Nora
    Nagy, I.
    Jancso, G.
    Vagvolgyi, Cs
    Somogyvari, F.
    ACTA BIOLOGICA HUNGARICA, 2013, 64 (02): : 262 - 265
  • [48] Sensitivity testing of trypanosome detection by PCR from whole blood samples using manual and automated DNA extraction methods
    Dunlop, J.
    Thompson, C. K.
    Godfrey, S. S.
    Thompson, R. C. A.
    EXPERIMENTAL PARASITOLOGY, 2014, 146 : 20 - 24
  • [49] A SIMPLE METHOD OF DNA EXTRACTION FROM WHOLE TISSUES AND BLOOD USING GLASS POWDER FOR DETECTION OF TRANSGENIC ANIMALS BY PCR
    ATTAL, J
    CAJEROJUAREZ, M
    HOUDEBINE, LM
    TRANSGENIC RESEARCH, 1995, 4 (02) : 149 - 150
  • [50] A self-powered, one-step chip for rapid, quantitative and multiplexed detection of proteins from pinpricks of whole blood
    Wang, Jun
    Ahmad, Habib
    Ma, Chao
    Shi, Qihui
    Vermesh, Ophir
    Vermesh, Udi
    Heath, James
    LAB ON A CHIP, 2010, 10 (22) : 3157 - 3162