DIFFERENCE OF NEOINTIMAL FORMATION IN BIFURCATION LESION BETWEEN SIROLIMUS-ELUTING STENT AND PACLITAXEL-ELUTING STENT: OPTICAL COHERENCE TOMOGRAPHY STUDY

被引:0
|
作者
Yoshimura, Takahiro [1 ]
Nishino, Masami [1 ]
Okamoto, Naotaka [1 ]
Tanaka, Akihiro [1 ]
Kikuchi, Atsushi [1 ]
Masaki, Takeshi [1 ]
Mori, Naoki [1 ]
Nakamura, Daisuke [1 ]
Lee, Yasuharu [1 ]
Taniike, Masayuki [1 ]
Makino, Nobuhiko [1 ]
Kato, Hiroyasu [1 ]
Egami, Yasuyuki [1 ]
Shutta, Ryu [1 ]
Morita, Hisaki [1 ]
Tanouchi, Jun [1 ]
Yamada, Yoshio [1 ]
机构
[1] Osaka Rosai Hosp, Div Cardiol, Osaka, Japan
关键词
D O I
10.1016/S0735-1097(11)61722-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:E1722 / E1722
页数:1
相关论文
共 50 条
  • [31] Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography
    Shinichiro Ikuta
    Kazuhiro Kobuke
    Yoshitaka Iwanaga
    Yoshifumi Nakauchi
    Kenji Yamaji
    Shunichi Miyazaki
    Heart and Vessels, 2014, 29 : 320 - 327
  • [32] NEOINTIMAL APPEARANCE OF LATE RESTENOSIS AFTER SIROLIMUS-ELUTING STENT IMPLANTATION: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Ino, Yasushi
    Shimamura, Kunihiro
    Shiono, Yasutsugu
    Komukai, Kenichi
    Ishibashi, Kohei
    Satogami, Keisuke
    Orii, Makoto
    Tanimoto, Takashi
    Kitabata, Hironori
    Masuno, Tomizou
    Kimura, Keizo
    Nakanishi, Hiroko
    Hirata, Kumiko
    Kubo, Takashi
    Tanaka, Atsushi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1868 - E1868
  • [33] Difference in Neointimal Growth on the Stent Struts Crossing a Side Branch Between Sirolimus-Eluting Stent and Bare-Metal Stent: Optical Coherence Tomography Analysis
    Terashima, Mitsuyasu
    Nakayama, Yoshiaki
    Suzuki, Yasuyoshi
    Inada, Tsuyoshi
    Asakura, Yasushi
    Matsubara, Tetsuo
    Matsuo, Hitoshi
    Asakura, Keiko
    Tsuchikane, Etsuo
    Ehara, Mariko
    Kinoshita, Yoshihisa
    Kimura, Masashi
    Nasu, Kenya
    Katoh, Osamu
    Suzuki, Takahiko
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 209I - 209I
  • [34] Comparison of Sirolimus versus Paclitaxel-eluting Stents for Treatment of Sirolimus-Eluting Stent Restenosis
    Habara, Seiji
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Kato, Harumi
    Oka, Naoki
    Fuku, Yasushi
    Hosogi, Shingo
    Hirono, Akitoshi
    Kawakami, Toru
    Maruo, Takeshi
    Tanaka, Hiroyuki
    Hasegawa, Daiji
    Imai, Masao
    Tasaka, Hiroshi
    Yamada, Chinatsu
    Okamoto, Yoji
    Otsuru, Suguru
    Miyamoto, Masakazu
    Saito, Naoki
    Shibayama, Kentaro
    Tsujimoto, Yuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A39 - A39
  • [35] Is There a Difference In Outcomes In Patients with Chronic Renal Insufficiency Who Are Implanted with a Sirolimus-eluting Stent Versus a Paclitaxel-eluting Stent?
    Syed, Asmir
    Collins, Sara
    Ben-Dor, Itsik
    Li, Yanlin
    Maluenda, Gabriel
    Torguson, Rebecca
    Zhenyi, Zhenyi
    Scheinowitz, Mickey
    Kaneshige, Kimberly
    Satler, Lowell F.
    Kent, Kenneth M.
    Suddath, William O.
    Pichard, Augusto D.
    Lindsay, Joseph
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 201D - 202D
  • [36] Neointimal proliferation around malapposed struts of a sirolimus-eluting stent: optical coherence tomography findings
    Takano, Masamichi
    Jang, Ik-Kyung
    Mizuno, Kyoichi
    EUROPEAN HEART JOURNAL, 2006, 27 (15) : 1763 - 1763
  • [38] Comparison of sirolimus-eluting stent, paclitaxel-eluting stent, and bare metal stent in the treatment of long coronary lesions
    Kim, YH
    Park, SW
    Lee, CW
    Hong, MK
    Gwon, HC
    Jang, Y
    Lee, MM
    Koo, BK
    Oh, DJ
    Seung, KB
    Tahk, SJ
    Yoon, J
    Park, SJ
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (02) : 181 - 187
  • [39] Difference in neointimal appearance between early and late restenosis after sirolimus-eluting stent implantation assessed by optical coherence tomography
    Ino, Yasushi
    Kubo, Takashi
    Kitabata, Hironori
    Ishibashi, Kohei
    Tanimoto, Takashi
    Matsuo, Yoshiki
    Shimamura, Kunihiro
    Shiono, Yasutsugu
    Orii, Makoto
    Komukai, Kenichi
    Yamano, Takashi
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Tanaka, Atsushi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    CORONARY ARTERY DISEASE, 2013, 24 (02) : 95 - 101
  • [40] Impact of Stent Platform of Paclitaxel-Eluting Stents - Assessment of Neointimal Distribution on Optical Coherence Tomography
    Otake, Hiromasa
    Shite, Junya
    Shinke, Toshiro
    Miyoshi, Naoki
    Kozuki, Amane
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Nagoshi, Ryoji
    Hariki, Hirotoshi
    Inoue, Takumi
    Osue, Tsuyoshi
    Taniguchi, Yu
    Hiranuma, Noritoshi
    Nishio, Ryo
    Kinutani, Hiroto
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2012, 76 (08) : 1880 - 1888