Development of a new copper(II) ion-selective poly(vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole

被引:0
|
作者
Akhond, M [1 ]
Ghaedi, M [1 ]
Tashkhourian, J [1 ]
机构
[1] Shiraz Univ, Dept Chem, Fac Sci, Shiraz 71454, Iran
关键词
copper(II) ion-selective electrode; ion sensor; PVC membrane; potentiometry; 2-mercaptobenzoxazole;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for Cu2+ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of Cu2+ sensor were investigated. The electrode exhibits good response for Cu2+ in a wide linear range of 5.0 x 10(-6)-1.6 x 10(-2) mol/L with a slope of 29.2 +/- 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 x 10(-6) mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.
引用
下载
收藏
页码:882 / 886
页数:5
相关论文
共 50 条
  • [31] NEW TYPE OF LEAD(II) ION-SELECTIVE CERAMIC MEMBRANE ELECTRODE
    HIRATA, H
    HIGASHIY.K
    ANALYTICA CHIMICA ACTA, 1971, 54 (03) : 415 - &
  • [32] COPPER(I) ACTIVITY OF THE COPPER(II) ION-SELECTIVE ELECTRODE
    STUNZI, H
    TALANTA, 1982, 29 (01) : 75 - 76
  • [33] Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a p-tert-butylcalix[4]arene-oxacrown-4
    Demirel, A
    Dogan, A
    Canel, E
    Memon, S
    Yilmaz, M
    Kiliç, E
    TALANTA, 2004, 62 (01) : 123 - 129
  • [34] Calixazacrown ethers for copper(II) ion-selective electrode
    Park, SJ
    Shon, OJ
    Rim, JA
    Lee, JK
    Kim, JS
    Nam, H
    Kim, H
    TALANTA, 2001, 55 (02) : 297 - 304
  • [35] EFFECT OF CHLORIDE-IONS ON BEHAVIOR OF ORION COPPER(II) ION-SELECTIVE ELECTRODE
    CROMBIE, DJ
    MOODY, GJ
    THOMAS, JDR
    TALANTA, 1974, 21 (10) : 1094 - 1098
  • [36] PREPARATION AND CHARACTERIZATION OF AN ION-SELECTIVE ELECTRODE FOR COPPER(II)
    SRIVASTAVA, SK
    PAL, N
    SINGH, RP
    AGARWAL, S
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1983, 22 (12): : 1033 - 1036
  • [37] INCORPORATION OF DODECYLBENZENESULFONIC ACID IN A POLY(VINYL-CHLORIDE) MATRIX CHLORIDE ION-SELECTIVE MEMBRANE-BASED ON TERTIARY AMMONIUM
    NOMURA, S
    ANALYST, 1995, 120 (02) : 503 - 504
  • [38] SURFACE-MORPHOLOGY OF ION-SELECTIVE MEMBRANE ELECTRODES .2. STUDIES ON THE COPPER(II)-SELECTIVE ELECTRODE
    PUNGOR, E
    TOTH, K
    PAPAY, MK
    POLOS, L
    MALISSA, H
    GRASSERBAUER, M
    HOKE, E
    EBEL, MF
    PERSY, K
    ANALYTICA CHIMICA ACTA, 1979, 109 (02) : 279 - 290
  • [39] LIQUID ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF COPPER(II)
    VLASOVA, GE
    ZOLOTOV, YA
    RYBAKOVA, EV
    ZARINSKII, VA
    SHPIGUN, LK
    VOLOBUEVA, IV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (04): : 480 - 484
  • [40] EFFECT OF CHLORIDE-ION AND IONIC-STRENGTH ON RESPONSE OF A COPPER(II) ION-SELECTIVE ELECTRODE
    OGLESBY, GB
    DUER, WC
    MILLERO, FJ
    ANALYTICAL CHEMISTRY, 1977, 49 (06) : 877 - 879