Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

被引:17
|
作者
Zou, Z. Y. [1 ,2 ]
Liu, H. Q. [1 ]
Ding, W. X. [3 ]
Chen, J. [3 ]
Brower, D. L. [3 ]
Lian, H. [1 ,2 ]
Wang, S. X. [1 ,2 ]
Li, W. M. [1 ,2 ]
Yao, Y. [1 ]
Zeng, L. [1 ]
Jie, Y. X. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 01期
关键词
DESIGN;
D O I
10.1063/1.5012820
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a lambda/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5 degrees-10 degrees to 1 degrees-2 degrees by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] MODULATED SUBMILLIMETER-LASER POLARIMETER FOR THE MEASUREMENT OF THE FARADAY-ROTATION BY A PLASMA
    MA, CH
    HUTCHINSON, DP
    SLUIS, KLV
    APPLIED PHYSICS LETTERS, 1979, 34 (03) : 218 - 220
  • [22] Note: Stability control of intermediate frequencies of a three laser far-infrared polarimeter-interferometer system
    Yu, Jiang-Tao
    Li, He-Ping
    Nie, Qiu-Yue
    Zou, Zhi-Yong
    Liu, Hai-Qing
    Bao, Cheng-Yu
    Jie, Yin-Xian
    Li, Zhan-Xian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (12):
  • [23] Toroidal interferometer/polarimeter density measurement system on ITER
    Kondoh, T
    Costley, AE
    Sugie, T
    Kawano, Y
    Malaquias, A
    Walker, CI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3420 - 3422
  • [24] Density profile evolution on EAST tokamak by the polarimeter/interferometer system
    Zhu, X.
    Zeng, L.
    Liu, H. Q.
    Jie, Y. X.
    Yang, Y.
    Gao, X.
    FUSION ENGINEERING AND DESIGN, 2018, 131 : 29 - 32
  • [25] Improvement of q profile by the polarimeter/interferometer system on EAST tokamak
    Zhu, X.
    Zeng, L.
    Liu, H.
    Qian, J.
    Zang, Q.
    Jie, Y.
    Zou, Z.
    Li, W.
    Yao, Y.
    Gao, X.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [26] Dual CO2 laser polarimeter for Faraday rotation measurement in tokamak plasmas
    Kawano, Y
    Chiba, S
    Shirai, H
    Inoue, A
    Nagashima, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 714 - 717
  • [27] Measurement of density fluctuation propagation direction via the far-forward collective scattering diagnostic based on polarimeter-interferometer
    Shi, P.
    Qiu, Q. S.
    Zhuang, G.
    Gao, L.
    Zhou, Y. N.
    Zhou, C. X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [28] First results of the J-TEXT high-resolution 3-wave polarimeter-interferometer system
    Zhuang, G.
    Chen, J.
    Li, Q.
    Gao, L.
    Wang, Z. J.
    Liu, Y.
    Chen, W.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [29] Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak
    Chen, J.
    Gao, L.
    Zhuang, G.
    Wang, Z. J.
    Gentle, K. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [30] Design of far-infrared polarimeter/interferometer system for EAST tokamak
    Liu, H. Q.
    Jie, Y. X.
    Ding, W. X.
    Brower, D. L.
    Zou, Z. Y.
    Wang, Z. X.
    Yang, Y.
    Qian, J. P.
    Zeng, L.
    Wei, X. C.
    Shen, J. S.
    An, Z. H.
    Lan, T.
    Wang, H. B.
    JOURNAL OF INSTRUMENTATION, 2013, 8