Beam shaper with optimized dose utility for helical cone-beam CT

被引:3
|
作者
Koehler, Thomas [1 ]
Brendel, Bernhard [1 ]
Proksa, Roland [1 ]
机构
[1] Philips Technol GmbH, Innovat Technol, Res Labs, D-22335 Hamburg, Germany
关键词
computed tomography; helical CT; dose reduction; beam-shaper; bowtie filter;
D O I
10.1118/1.3577766
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a new design of an x-ray beam shaper for helical computed tomography ( CT) that increases the dose utilization. Methods: For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e., data acquired at larger cone-angles, are used with smaller weights than data from the central detector rows. Given this spatial variation of the back-projection weights, a beam shaper is designed that creates a spatial variation of the noise variance across the detector such that the used back-projection weights are the statistically optimal weights. The effect of the beam shaper on the reconstructed images are studied using simulated data and analytical as well as iterative reconstruction algorithms. Results: For a particular analytical reconstruction algorithm, we obtain an average reduction of the noise by 12% within the object. In combination with iterative reconstruction, the beam shaper creates an insensitivity to patient motion without introducing any heuristic data weighting. Conclusions: The demonstrated noise reduction by 12% is equivalent to a possible dose saving of 25%. This dose saving can be achieved by a relatively minor hardware change in the CT system and it does not require any changes to the reconstruction algorithm. (c) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3577766]
引用
收藏
页码:S76 / S84
页数:9
相关论文
共 50 条
  • [1] Sinogram Restoration in Helical Cone-Beam CT
    Little, K.
    La Riviere, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [2] Helical cone-beam CT for radiation therapy
    Yu, LF
    Pan, XC
    Pelizzari, CA
    Zou, Y
    Munro, P
    Riem, H
    Kaissl, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1890 - 1890
  • [3] A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product
    Kim, S.
    Song, H.
    Samei, E.
    Yin, F.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Estimating organ dose with optimized peak dose index in cone-beam CT scans
    Haba, Tomonobu
    Nishihara, Yusei
    Saito, Yasunori
    Tomimura, Takeshi
    Ogawa, Shuta
    Tanabe, Kaho
    Asada, Yasuki
    Kobayashi, Masanao
    Koyama, Shuji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118
  • [5] Multirow detector and cone-beam spiral/helical CT
    Wang, G
    Crawford, CR
    Kalender, WA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 817 - 821
  • [6] Noise Properties in Helical Cone-beam CT Images
    Xia, Dan
    Sidky, Emil Y.
    Yu, Lifeng
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3428 - 3430
  • [7] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [8] Exact and approximate algorithms for helical cone-beam CT
    Kudo, H
    Rodet, T
    Noo, F
    Defrise, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2913 - 2931
  • [9] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [10] Helical cone-beam tomography
    Turbell, H
    Danielsson, PE
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2000, 11 (01) : 91 - 100