MR-guided biopsy: A review of current techniques and applications

被引:85
|
作者
Weiss, Clifford R. [1 ]
Nour, Sherif Gamal [2 ]
Lewin, Jonathan S. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
关键词
MRI; biopsy; percutaneous therapy; multiplanar imaging; imaging system development; real-time imaging; interventional magnetic resonance; MR guidance; frameless stereotaxy; augmented reality; image fusion; head and neck; sclerotherapy; abdomen; liver; prostate; breast; musculoskeletal;
D O I
10.1002/jmri.21270
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Biopsy has become a cornerstone of modem medicine and most modem biopsies are performed percutaneously using image guidance, typically computed tomography or ultrasound. MR-guided biopsy offers many advantages over these more traditional modalities, and the recent development of interventional MR imaging techniques has made MR-guided percutaneous biopsies and aspirations a clinical reality. As the field of MR-guided procedures continues to expand and to attract more attention from radiologists, it is important to understand the concepts, techniques, applications, advantages, and limitations of MR-guided biopsy/percutaneous procedures. Radiologists should also recognize the need for their significant involvement in the technical aspects of MR-guided procedures, since several user-defined parameters can alter device visualization in the MR imaging environment and affect procedure safety. This article reviews the prerequisites, systems, and applications of MR-guided biopsy.
引用
收藏
页码:311 / 325
页数:15
相关论文
共 50 条
  • [31] MR-Guided pain therapy: Principles and clinical applications
    Fritz, J.
    Pereira, P. L.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 914 - 924
  • [32] Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
    C. Perlet
    A. Heinig
    X. Prat
    J. Casselman
    L. Baath
    H. Sittek
    C. Stets
    J. Lamarque
    I. Anderson
    P. Schneider
    P. Taourel
    M. Reiser
    S. Heywang-Köbrunner
    European Radiology, 2002, 12 : 1463 - 1470
  • [33] Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
    Perlet, C
    Heinig, A
    Prat, X
    Casselman, J
    Baath, L
    Sittek, H
    Stets, C
    Lamarque, J
    Anderson, I
    Schneider, P
    Taourel, P
    Reiser, M
    Heywang-Köbrunner, SH
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1463 - 1470
  • [34] MR-guided vacuum assisted breast biopsy with the ATEC® breast biopsy and excision system
    Hauth, E. A.
    Umutlu, L.
    Quinsten, A.
    Kuemmel, S.
    Kimmig, R.
    Forsting, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2008, 68 (09) : 901 - 906
  • [35] INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM
    SILVERMAN, SG
    COLLICK, BD
    FIGUEIRA, MR
    KHORASANI, R
    ADAMS, DF
    NEWMAN, RW
    TOPULOS, GP
    JOLESZ, FA
    RADIOLOGY, 1995, 197 (01) : 175 - 181
  • [36] MR-GUIDED NEEDLE-BIOPSY WITH A HIGH-FIELD-STRENGTH MR SYSTEM
    LUFKIN, RB
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1268 - 1268
  • [37] A review of potential applications of MR-guided focused ultrasound for targeting brain tumor therapy
    Lamsam, Layton
    Johnson, Eli
    Connolly, Ian D.
    Wintermark, Max
    Gephart, Melanie Hayden
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [38] MR-guided biopsies
    H.-B. Gehl
    C. Frahm
    Der Radiologe, 1998, 38 : 194 - 199
  • [39] MR-guided biopsies
    Gehl, HB
    Frahm, C
    RADIOLOGE, 1998, 38 (03): : 194 - 199
  • [40] Monitoring and visualization techniques for MR-guided laser ablations in an open MR system
    Kettenbach, J
    Silverman, SG
    Hata, N
    Kuroda, K
    Saiviroonporn, P
    Zientara, GP
    Morrison, PR
    Hushek, SG
    Black, PM
    Kikinis, R
    Jolesz, FA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 933 - 943