Simple and sensitive colorimetric assay system for horseradish peroxidase using microfluidic paper-based devices

被引:48
|
作者
Busa, Lori Shayne Alamo [1 ,2 ]
Maeki, Masatoshi [3 ]
Ishida, Akihiko [3 ]
Tani, Hirofumi [3 ]
Tokeshi, Manabu [3 ,4 ,5 ,6 ]
机构
[1] Hokkaido Univ, Grad Sch Chem Sci & Engn, Kita Ku, Kita 13 Nishi 8, Sapporo, Hokkaido 0608628, Japan
[2] Nueva Vizcaya State Univ, Dept Phys Sci, Bayombong 3700, Nueva Vizcaya, Philippines
[3] Hokkaido Univ, Div Appl Chem, Fac Engn, Kita Ku, Kita 13 Nishi 8, Sapporo, Hokkaido 0608628, Japan
[4] Nagoya Univ, ImPACT Res Ctr Adv Nanobiodevices, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan
[5] Nagoya Univ, Innovat Res Ctr Prevent Med Engn, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648601, Japan
[6] Nagoya Univ, Inst Innovat Future Soc, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648601, Japan
关键词
Paper-based devices; Paper substrates; Horseradish peroxidase; RESPIRATORY SYNCYTIAL VIRUS; ELECTROCHEMICAL IMMUNOASSAY; AMPLIFICATION; DEPOSITION; ELECTRODE; BIOASSAYS; BINDING; METALS; SENSOR; LABELS;
D O I
10.1016/j.snb.2016.06.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes the development of a simple, portable assay system using microfluidic paper-based analytical devices (mu PADs) coupled with colorimetric detection for rapid measurements. The properties of different paper substrates were first investigated to determine which type of paper would be the most suitable for the fabrication of the mu PADs. Simultaneous detection of horseradish peroxidase (HRP) utilizing a 5 mu L sample analytical volume was demonstrated using a single mu PAD. Hydrophilic test regions were separated by hydrophobic barriers, which were fabricated through photolithography. These test regions were immobilized with 10 mM of 3,3',5,5'-tetramethylbenzidine for HRP assay. The detection range obtained with the proposed system covered HRP concentrations from 0.37 to 124 fmol (or 31000 ng mL(-1)). The detection limit (blank + 3 sigma) for HRP was calculated to be 0.69 fmol (or 5.58 ng mL(-1)) through a 4-parameter logistic nonlinear regression using results obtained within a 15 min assay time. The findings obtained using the developed system suggest that mu PAD assay systems for simple but highly sensitive measurements can be designed to give on-site determinations of target compounds using peroxidase-conjugated molecules. ((c)) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 441
页数:9
相关论文
共 50 条
  • [1] A colorimetric assay system for dopamine using microfluidic paper-based analytical devices
    Liu, Chunye
    Gomez, Frank A.
    Miao, Yanqing
    Cui, Ping
    Lee, Wilson
    [J]. TALANTA, 2019, 194 : 171 - 176
  • [2] Evaluation of chromogenic substrates for horseradish peroxidase on paper-based microfluidic devices
    Vazquez-Alvarado, Miguel
    Vanasupa, ShiLu
    Valdez, Elide Herrera
    Pama, Alyssa M.
    Crowder, Maile J.
    Vanasupa, Linda
    Martinez, Nathaniel W.
    Martinez, Andres W.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
  • [3] Simple and Sensitive Detection of Bacterial Hydrogen Sulfide Production Using a Paper-Based Colorimetric Assay
    Ahn, Byung-Ki
    Ahn, Yong-Jin
    Lee, Young-Ju
    Lee, Yeon-Hee
    Lee, Gi-Ja
    [J]. SENSORS, 2022, 22 (15)
  • [4] A paper-based colorimetric assay system for sensitive cysteine detection using a fluorescent probe
    Zhang, Jian
    Miao, Yanqing
    Cheng, Zhao
    Liang, Lingling
    Ma, Xiaoya
    Liu, Chunye
    [J]. ANALYST, 2020, 145 (05) : 1878 - 1884
  • [5] Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin
    Kudo, Hiroko
    Maejima, Kento
    Hiruta, Yuki
    Citterio, Daniel
    [J]. SLAS TECHNOLOGY, 2020, 25 (01): : 47 - 57
  • [6] Use of multiple colorimetric indicators for paper-based microfluidic devices
    Dungchai, Wijitar
    Chailapakul, Orawon
    Henry, Charles S.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 227 - 233
  • [7] A colorimetric assay for sensitive detection of hydrogen peroxide and glucose in microfluidic paper-based analytical devices integrated with starch-iodide-gelatin system
    Liu, Meng-Meng
    Lian, Xin
    Liu, Hui
    Guo, Zi-Zhen
    Huang, Hui-Hong
    Lei, Yun
    Peng, Hua-Ping
    Chen, Wei
    Lin, Xin-Hua
    Liu, Ai-Lin
    Xia, Xing-Hua
    [J]. TALANTA, 2019, 200 : 511 - 517
  • [8] Determination of glutamate using paper-based microfluidic devices with colorimetric detection for food samples
    Danchana, Kaewta
    Iwasaki, Hiroshi
    Ochiai, Kenta
    Namba, Haruka
    Kaneta, Takashi
    [J]. MICROCHEMICAL JOURNAL, 2022, 179
  • [9] Colorimetric Detection of Alkaline Phosphatase on Microfluidic Paper-based Analysis Devices
    Chen Xi
    Chen Jin
    Zhang Hui-Yan
    Wang Fu-Bing
    Wang Fang-Fang
    Ji Xing-Hu
    He Zhi-Ke
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (04) : 591 - 596
  • [10] Quantitative biomarker assay with microfluidic paper-based analytical devices
    Xu Li
    Junfei Tian
    Wei Shen
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 495 - 501