Parallel Reaction Monitoring Mode for Atenolol Quantification in Dried Plasma Spots by Liquid Chromatography Coupled with High-Resolution Mass Spectrometry

被引:1
|
作者
Aksenova, Liliya, V [1 ,2 ]
Koval, Vladimir V. [1 ,2 ]
Chernonosov, Alexander A. [1 ]
机构
[1] SB RAS, Inst Chem Biol & Fundamental Med, Lavrentiev Ave 8, Novosibirsk 630090, Russia
[2] Novosibirsk State Univ, Dept Nat Sci, Pirogova Str 2, Novosibirsk 630090, Russia
关键词
dried plasma spot; DPS; DBS; atenolol; PRM; LC-HRMS; parallel reaction monitoring; LC-MS/MS; BLOOD SPOTS; INTERNAL STANDARD; SAMPLES; HRMS; HEMATOCRIT; VALIDATION;
D O I
10.3390/pr10071240
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, we reported a rapid, sensitive, robust, and validated method for atenolol quantification in dried plasma spots (DPS) by liquid chromatography with high-resolution mass spectrometry (LC-HRMS) using parallel reaction monitoring mode (PRM). Aliquots of 25 mu L human plasma were placed onto Whatman 903 Cards and air-dried. Disks (3.2 mm internal diameter) were punched, and a 100 mu L working internal standard solution was added to each sample and then incubated on a shaker for 15 min at 40 degrees C, followed by rapid centrifugation (10,000x g, 10 s). The supernatant was transferred into 300 mu L vials for subsequent LC-HRMS analysis. After chromatographic separation, atenolol and the internal standard were quantified in positive-ion parallel reaction monitoring mode by detection of all target product ions at 10 ppm tolerances. The total time of the analysis was 5 min. The calibration curve was linear in the range of 5-1000 ng/mL with interday and intraday precision levels and biases of <14.4%, and recovery was 62.9-81.0%. The atenolol in DPS was stable for >= 30 days at 25 and 4 degrees C. This fully validated method is selective and suitable for atenolol quantitation in DPS using LC-HRMS.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Therapeutic drug monitoring in dried blood spots using liquid microjunction surface sampling and high resolution mass spectrometry
    Gaissmaier, Tanja
    Siebenhaar, Markus
    Todorova, Vanya
    Huellen, Volker
    Hopf, Carsten
    ANALYST, 2016, 141 (03) : 892 - 901
  • [32] Analysis of metronidazole in equine plasma using liquid chromatography/tandem mass spectrometry and high-resolution accurate mass spectrometry
    Ilomuanya, Margaret
    Uboh, Cornelius
    Ciallella, John
    Li, Xiaoging
    Liu, Ying
    Ifudu, Ndu
    Azubuike, Chukwuemeka
    Igwilo, Cecilia
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (08) : 753 - 763
  • [33] A Validated Method for Quantification of Efavirenz in Dried Blood Spots Using High-Performance Liquid Chromatography-Mass Spectrometry
    Amara, Alieu B.
    Else, Laura J.
    Tjia, John
    Olagunju, Adeniyi
    Puls, Rebekah L.
    Khoo, Saye
    Back, David J.
    THERAPEUTIC DRUG MONITORING, 2015, 37 (02) : 220 - 228
  • [34] Quantification of glycopeptides by multiple reaction monitoring liquid chromatography/tandem mass spectrometry
    Song, Ehwang
    Pyreddy, Swetha
    Mechref, Yehia
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (17) : 1941 - 1954
  • [35] Enantioselective quantitative analysis of amphetamine in human plasma by liquid chromatography/high-resolution mass spectrometry
    Hans J. Leis
    Günter Fauler
    Werner Windischhofer
    Analytical and Bioanalytical Chemistry, 2014, 406 : 4473 - 4480
  • [36] Enantioselective quantitative analysis of amphetamine in human plasma by liquid chromatography/high-resolution mass spectrometry
    Leis, Hans J.
    Fauler, Guenter
    Windischhofer, Werner
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (18) : 4473 - 4480
  • [37] Felodipine quantification in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry
    Migliorança, LH
    Barrientos-Astigarraga, RE
    Schug, BS
    Blume, HH
    Pereira, AS
    De Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (02): : 217 - 223
  • [38] Plasma phospholipid profiling of a mouse model of anxiety disorder by hydrophilic interaction liquid chromatography coupled to high-resolution mass spectrometry
    Berkecz, Robert
    Kormoczi, Timea
    Tomosi, Ferenc
    Szegedi, Viktor
    Horvath, Janos
    Kovacs, Nora
    Janaky, Tamas
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (06)
  • [39] Perspectives of Liquid Chromatography Coupled to Low- and High-Resolution Mass Spectrometry for Screening, Identification, and Quantification of Drugs in Clinical and Forensic Toxicology
    Maurer, Hans H.
    THERAPEUTIC DRUG MONITORING, 2010, 32 (03) : 324 - 327
  • [40] Simultaneous quantification of mefloquine (+)- and (-)-enantiomers and the carboxy metabolite in dried blood spots by liquid chromatography/tandem mass spectrometry
    Geditz, Mirjam C. K.
    Lindner, Wolfgang
    Laemmerhofer, Michael
    Heinkele, Georg
    Kerb, Reinhold
    Ramharter, Michael
    Schwab, Matthias
    Hofmann, Ute
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 968 : 32 - 39