Noninvasive continuous arterial pressure monitoring during anesthesia induction in patients undergoing cardiac surgery

被引:7
|
作者
Frank, Paul [1 ]
Logemann, Frank [1 ]
Gras, Clemens [1 ]
Palmaers, Thomas [1 ]
机构
[1] Hannover Med Sch, Dept Anesthesiol & Intens Care Med, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Cardiac anesthesia; clearSight; hemodynamic monitoring; induction; Nexfin; volume-clamp; BLOOD-PRESSURE; APPLANATION TONOMETRY; ACCURACY; PRECISION; NEXFIN; DEVICE; AGREEMENT; FINAPRES;
D O I
10.4103/aca.ACA_120_20
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: In this study we compared noninvasive arterial pressure measurement using ClearSight (TM) vascular-unloading-technique (Edwards Lifesciences Corp, Irvine, CA) with invasive arterial pressure measurement during induction of anesthesia undergoing mayor cardiac surgery. Design: Prospective, monocentric. Setting: University hospital. Participants: 54 patients undergoing mayor cardiac surgery. Interventions: During induction all patients were simultaneously monitored with invasive (reference method) and noninvasive arterial pressure measurement (test-method) over a mean time period of 27 minutes. Measurements and Main Results: We observed slightly lower systolic and mean arterial pressures noninvasive than invasive. For systolic arterial pressure the mean of the differences was -18,05 mmHg (p < 0,05, SD +/- 16,78 mmHg), the mean arterial pressure MAP -5,47 mmHg (p < 0,05, SD +/- 11,08 mmHg) and for diastolic pressure -1,09 mmHg (p < 0,05, SD +/- 11,15 mmHg),. The mean of the differences in heartrate was 1,15 (p < 0,05, SD +/- 6,9 mmHg). When considering all measured values of the invasively measured MAP and the ClearSight (TM)-MAP at the same timestamp over the recording interval, an almost identical progress can be seen that indicates a sufficient mapping of the hemodynamic changes. The percentage error for mean arterial, systolic and diastolic pressure measured by ClearSight (TM) amounts to 25,95 %, 26,77 % and 34,16 %, respectively. Conclusions: We conclude that ClearSight (TM) is a good option for hemodynamic monitoring during induction of anesthesia. Taking into account the limitations, non-invasive arterial blood pressure measurement offers sufficient security to safely initiate anesthesia, especially when MAP is of particular interest. The use of non-invasive arterial blood pressure measurement with ClearSight (TM) during induction of anesthesia in patients scheduled for major cardiac surgery is reliable and easy to use.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 50 条
  • [21] FloTrac for monitoring arterial pressure and cardiac output during phaeochromocytoma surgery
    Collange, O.
    Xavier, L.
    Kuntzman, H.
    Calon, B.
    Schaeffer, R.
    Pottecher, T.
    Diemunsch, P.
    Pessaux, P.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (09) : 779 - 780
  • [22] CONTINUOUS NONINVASIVE ARTERIAL MONITORING
    SALTER, C
    WESTERN JOURNAL OF MEDICINE, 1988, 149 (01): : 75 - 75
  • [23] Perioperative Continuous Noninvasive Cardiac Output Monitoring in Cardiac Surgery Patients by a Novel Capnodynamic Method
    Tusman, Gerardo
    Acosta, Cecilia M.
    Wallin, Mats
    Hallback, Magnus
    Esperatti, Mariano
    Peralta, Georgina
    Eugenia Gonzalez, Maria
    Suarez-Sipmann, Fernando
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (08) : 2900 - 2907
  • [24] Noninvasive vs. invasive arterial pressure during pediatric non cardiac surgery
    Calabrese, Silvio
    Angileri, Sandra
    Paolicchi, Olivia
    Mancinelli, Paola
    Colosimo, Denise
    Ricci, Zaccaria
    MINERVA ANESTESIOLOGICA, 2023, 89 (09) : 841 - 842
  • [25] CONTINUOUS NONINVASIVE MONITORING OF CARDIAC-OUTPUT WITH ESOPHAGEAL DOPPLER ULTRASOUND DURING CARDIAC-SURGERY
    MARK, JB
    STEINBROOK, RA
    GUGINO, LD
    MADDI, R
    HARTWELL, B
    SHEMIN, R
    DISESA, V
    RIDA, WN
    ANESTHESIA AND ANALGESIA, 1986, 65 (10): : 1013 - 1020
  • [26] Comparison of parameter types for the calibration of noninvasive continuous cardiac output monitoring of patients undergoing lumbar spinal surgery in the prone position
    Lee, Seung Cheol
    Lee, Gang Hyun
    Lee, Tae Young
    Park, Sang Yoong
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (06) : 2009 - 2019
  • [27] The Relation Between Cardiac Index and Mean Arterial Pressure During Anesthesia and Surgery Response
    Kouz, Karim
    Sessler, Daniel I.
    Saugel, Bernd
    ANESTHESIA AND ANALGESIA, 2022, 135 (01): : E5 - E5
  • [28] Wireless continuous arterial blood pressure monitoring during surgery: A pilot study
    Oyri, K
    Balasingham, I
    Samset, E
    Hogetveit, JO
    Fosse, E
    ANESTHESIA AND ANALGESIA, 2006, 102 (02): : 478 - 483
  • [29] Feasibility and Accuracy of Noninvasive Continuous Arterial Pressure Monitoring during Transcatheter Atrial Fibrillation Ablation
    Di Cori, Andrea
    Parollo, Matteo
    Fiorentini, Federico
    Della Volpe, Salvatore
    Mazzocchetti, Lorenzo
    Barletta, Valentina
    Segreti, Luca
    Viani, Stefano
    De Lucia, Raffaele
    Paperini, Luca
    Canu, Antonio
    Grifoni, Gino
    Soldati, Ezio
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [30] Accuracy of Continuous Noninvasive Arterial Pressure Monitoring in Living-Liver Donors During Transplantation
    Araz, Coskun
    Zeyneloglu, Pinar
    Pirat, Arash
    Veziroglu, Nukhet
    Firat, Aynur Camkiran
    Arslan, Gulnaz
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2015, 13 : 301 - 305