Impact on quantitative fit-test results after application of prophylactic hydrocolloid dressing under N95 respirators

被引:7
|
作者
Ng, Irene [1 ,2 ]
Kave, Benjamin [1 ]
Begg, Fiona [3 ]
Sage, Sarah [4 ]
Segal, Reny [1 ,2 ]
Williams, Daryl L. [1 ,2 ]
机构
[1] Royal Melbourne Hosp, Dept Anaesthesia & Pain Management, Parkville, Vic, Australia
[2] Univ Melbourne, Parkville, Vic, Australia
[3] Royal Melbourne Hosp, Hlth & Safety People & Culture, Parkville, Vic, Australia
[4] Royal Melbourne Hosp, Wound Management, Parkville, Vic, Australia
来源
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY | 2022年 / 43卷 / 08期
关键词
D O I
10.1017/ice.2021.293
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective: Discomfort and device-related pressure injury (DRPI) caused by N95 filtering facepiece respirators (FFRs) are common. The use of prophylactic hydrocolloid dressings is one of the strategies that may improve comfort and reduce DRPI. In this study, we investigated the impact of these dressings on N95 respirator fit. Methods: We performed a repeat quantitative fit testing through the Respiratory Protection Program on 134 healthcare workers (HCWs), who applied hydrocolloid dressings on the bridge of their nose under the N95 FFRs that they passed the initial fit test with, but reported discomfort with the FFR. Results: With the hydrocolloid dressings in place, the fit-test pass rate for the semirigid cup style (3M 1860) was 94% (108 of 115); for the the vertical flat-fold style (BYD), the pass rate was 85% (44 of 52); for the duckbill style (BSN medical ProShield and Halyard Fluidshield), the pass rate was 81% (87 of 108); and for the 3-panel flat-fold style (3M Aura) N95 FFRs, the pass rate was 100% (3 of 3). There was a statistically significant reduction in the overall fit factors for both the vertical flat-fold and duckbill type N95 respirators after the application of hydrocolloid dressings. Conclusions: Hydrocolloid dressings are likely to disturb the mask seal for nonrigid-style N95 FFRs, particularly the vertical flat-fold style and the duckbill style N95 FFRs. Given the risk of mask seal disturbance of N95 respirators as shown in this study, we advocate that any HCW requiring the use of prophylactic dressings should undergo repeat quantitative fit testing with the dressing in place prior to using the dressing and mask in combination.
引用
收藏
页码:993 / 996
页数:4
相关论文
共 22 条
  • [11] Respiratory protection against Mycobacterium tuberculosis:: Quantitative fit test outcomes for five Type N95 filtering-facepiece respirators
    Lee, K
    Slavcev, A
    Nicas, M
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (01) : 22 - 28
  • [12] Use of Thin Dressings Under N95 Respirators: Exploring Their Effect on Quantitative Fit Testing Results to Guide Hospital Practice During the COVID-19 Pandemic
    Guschel, Susan
    Chmiel, Karen
    Rosenstein, Jennifer
    WOUND MANAGEMENT & PREVENTION, 2020, 66 (11) : 13 - 17
  • [13] Comparing mask fit and usability of traditional and nanofibre N95 filtering facepiece respirators before and after nursing procedures
    Suen, L. K. P.
    Guo, Y. P.
    Ho, S. S. K.
    Au-Yeung, C. H.
    Lam, S. C.
    JOURNAL OF HOSPITAL INFECTION, 2020, 104 (03) : 336 - 343
  • [14] P2/N95 filtering facepiece respirators: Results of a large-scale quantitative mask fit testing program in Australian health care workers
    Milosevic, Maxim
    Biswas, Raaj Kishore
    Innes, Lesley
    Ng, Martin
    Darendeliler, Ali Mehmet
    Wong, Alice
    Denney-Wilson, Elizabeth
    AMERICAN JOURNAL OF INFECTION CONTROL, 2022, 50 (05) : 509 - 515
  • [15] Repeated vaporised hydrogen peroxide disinfection of 3M 1860 N95 mask respirators does not degrade quantitative fit performance
    Moschella, Phillip
    Liao, Wesley
    Litwin, Alain
    Foulk, Jonn
    Anthony, Jeff
    Player, Matt
    Chang, Jerry
    Cole, Christine
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 126 (03) : E125 - E127
  • [16] Randomized crossover study comparing quantitative fit tests between Trident™ and 3M™ Aura™ N95/P2 respirators
    Williams, D. L.
    Kave, B.
    Begg, F.
    Bodas, C.
    Ng, I.
    INFECTION DISEASE & HEALTH, 2022, 27 (02) : 61 - 65
  • [17] Fit Test for N95 Filtering Facepiece Respirators and KF94 Masks for Healthcare Workers: a Prospective Single-center Simulation Study
    Park, Jin Ju
    Seo, Yu Bin
    Lee, Jacob
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2021, 36 (21)
  • [18] Striving to be the fittest: quantitative P2/N95 respirator fit test results among hospital staff during the COVID-19 pandemic
    Zhang, Melanie
    Hackett, Liam
    Smith, Jesse
    Pritchard, Zoe
    Casey, Matthew
    Low, Caitlin
    Buntine, Paul
    ANTIMICROBIAL STEWARDSHIP & HEALTHCARE EPIDEMIOLOGY, 2023, 3 (01):
  • [19] Comparison of fit factors among healthcare providers working in the Emergency Department Center before and after training with three types of N95 and higher filter respirators
    Kim, Hongjung
    Lee, Juncheol
    Lee, Sanghyun
    Oh, Jaehoon
    Kang, Boseung
    Lim, Tae Ho
    Kang, Hyunggoo
    MEDICINE, 2019, 98 (06)
  • [20] Assessment of the Qualitative Fit Test and Quantitative Single-Pass Filtration Efficiency of Disposable N95 Masks Following Gamma Irradiation
    Cramer, Avilash
    Tian, Enze
    Galanek, Mitchell
    Lamere, Edward
    Li, Ju
    Gupta, Rajiv
    Short, Mike
    JAMA NETWORK OPEN, 2020, 3 (05) : E209961