Choice of replacement fluid dialysate anion in continuous renal replacement therapy

被引:12
|
作者
Macias, WL
机构
[1] INDIANA UNIV,SCH MED,INDIANAPOLIS,IN
[2] ELI LILLY & CO,LILLY LAB CLIN RES,INDIANAPOLIS,IN 46285
关键词
hemofiltration; hemodiafiltration; ARF; dialysis solutions; lactate; bicarbonate; citrate; acetate;
D O I
10.1016/S0272-6386(96)90075-X
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Normalization of acid-base balance in patients with acute renal failure (ARF) is a primary goal of continuous extracorporeal renal replacement therapy (CRRT). During CRRT, alkali administration, either in the replacement fluid or by diffusive uptake from the dialysate, must replace not only the bicarbonate lost in the buffering of endogenous acid production, but also the bicarbonate lost across the hemodiafilter. In most patients with ARF, a buffer concentration of approximately 30 to 35 mmol/L and an ultrafiltration rate (or dialysate flow rate) approaching or exceeding 1 L/hr can be expected to normalize the acid-base status within 1 to 2 days. In individuals with ARF and lactic acidemia, the buffer load may need to approach greater than or equal to 50 mmol/L to correct the associated metabolic acidemia. Acetate, bicarbonate, citrate, and lactate are the possible choices for bicarbonate or bicarbonate-equivalent administration during CRRT. Acetate- and lactate-based physiologic solutions have the advantage of being commercially available. Under normal conditions, acetate and lactate are metabolized rapidly to bicarbonate. Under conditions where the conversion pathways may be impaired, such as in severe hypoxic or shock states, excessive accumulation of these anions is possible. In the latter situation, the rate of anion conversion to bicarbonate may be slower than the rate of bicarbonate loss across the hemodiafilter, and a worsening of metabolic acidemia may occur. In addition, the administration of large amounts of lactate may result in increased urea generation. Bicarbonate has the major advantage of being the most physiologic anion. Unfortunately, the production of a commercially available bicarbonate-based physiologic solution is difficult because of the loss of bicarbonate from the solution or the formation of calcium and magnesium salts. The use of citrate as an anticoagulant obviates the need for additional alkali because citrate is metabolized to bicarbonate. Excessive citrate accumulation is rare, even in the setting of severe hepatic failure. (C) 1996 by the National Kidney Foundation, Inc.
引用
收藏
页码:S15 / S20
页数:6
相关论文
共 50 条
  • [21] Continuous renal replacement therapy
    Tonelli, M
    Manns, B
    Pannu, N
    Klarenbach, S
    Jindal, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (09): : 1001 - 1002
  • [22] High Anion Gap Metabolic Acidosis on Continuous Renal Replacement Therapy
    Sriperumbuduri, Sriram
    Clark, Edward
    Biyani, Mohan
    Ruzicka, Marcel
    KIDNEY INTERNATIONAL REPORTS, 2020, 5 (10): : 1833 - 1835
  • [23] Electrolyte disorders and substitution fluid in continuous renal replacement therapy
    Locatelli, F
    Pontoriero, G
    Di Filippo, S
    KIDNEY INTERNATIONAL, 1998, 53 : S151 - S155
  • [24] Fluid balance management during continuous renal replacement therapy
    Prowle, John
    Mehta, Ravindra
    SEMINARS IN DIALYSIS, 2021, 34 (06) : 440 - 448
  • [25] FLUID OVERLOAD IN NEONATES RECEIVING CONTINUOUS RENAL REPLACEMENT THERAPY
    Lee, Sang Teak
    Cho, Heeyeon
    PEDIATRIC NEPHROLOGY, 2015, 30 (12) : 2234 - 2234
  • [26] Bicarbonate dialysate for continuous renal replacement therapy in intensive care unit patients with acute renal failure
    Leblanc, M
    Moreno, L
    Robinson, OP
    Tapolyai, M
    Paganini, EP
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 26 (06) : 910 - 917
  • [27] Effects of Dialysate Flow Configurations in Continuous Renal Replacement Therapy on Solute Removal: Computational Modeling
    Kim, Jeong Chul
    Cruz, Dinna
    Garzotto, Francesco
    Kaushik, Manish
    Teixeria, Catarina
    Baldwin, Marie
    Baldwin, Ian
    Nalesso, Federico
    Kim, Ji Hyun
    Kang, Eungtaek
    Kim, Hee Chan
    Ronco, Claudio
    BLOOD PURIFICATION, 2013, 35 (1-3) : 106 - 111
  • [28] Protocolized fluid balance neutralization during continuous renal replacement therapy
    Raghavan Murugan
    John Prowle
    William Beaubien-Souligny
    Intensive Care Medicine, 2024, 50 (12) : 2141 - 2143
  • [29] Fluid overload and outcomes in neonates receiving continuous renal replacement therapy
    Lee, Sang Taek
    Cho, Heeyeon
    PEDIATRIC NEPHROLOGY, 2016, 31 (11) : 2145 - 2152
  • [30] Fluid balance error in continuous renal replacement therapy: A technical note
    Bagshaw, S. M.
    Baldwin, I.
    Fealy, N.
    Bellomo, R.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (05): : 435 - 440