Decomposition of mixed malodorants in a wire-plate pulse corona reactor

被引:23
|
作者
Shi, Y [1 ]
Ruan, J [1 ]
Wang, X [1 ]
Ll, W [1 ]
Tan, T [1 ]
机构
[1] Zhejiang Univ, Inst Environm Engn, Hangzhou 310027, Peoples R China
关键词
D O I
10.1021/es048583q
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Decomposition characteristics of two groups of representative mixed malodorants (1, ethanethiol + hydrogen sulfide; 2, ethanethiol + ammonia) in air were investigated employing a wire-plate pulse Corona reactor. A new type of high-voltage pulse generator with a thyratron switch and a Blumlein pulse-forming network (BPFN) was used in our experiments. The experiments were conducted at a gas-flow rate of, 13 m(3)/h. Important parameters, including peak voltage, chemical structures of malodorants, pulse frequency, and initial concentration, which influenced the removal efficiency, were investigated. The results showed that the mixed malodorants could be treated effectively by pulse Corona. The removal efficiencies of 200 mg/m(3) C2H5SH and 200 mg/m(3) H2S for group I were 95.6% and 100%, respectively, which were almost equal to those of the two pollutants separately. The energy cost was about 65.1-81.4 A, which was 31.5-45.2% lower than for treating pollutants alone. The removal efficiencies of 105 mg/m(3) C2H5SH and 40 mg/m3 NH3 for group 2 were 93.1% and almost 100%, and the energy cost was 65.1 J/L, 55.6% lower than that which was treated separately. In the case of two groups of mixed malodorants removal, NO,, O-3, SO2, CO2, and CO were all observed. Moreover, some sulfur and white crystal ammonium nitrates were discovered adhering to the Corona wires in the removal of groups 1 and 2, respectively. A dynamics model was developed to describe the relation of the removal efficiency with specific energy density and initial concentration. In the case of group 1 removal,the decomposition rate constants decreased as compared to the single treating. As for group 2 removal, the decomposition rate constants increased, especially for NH3. According to the results, the optimization design for the reactor and the matching of high pulse voltage source can be reckoned.
引用
收藏
页码:6786 / 6791
页数:6
相关论文
共 50 条
  • [31] Toluene removal characteristics by a superimposed wire-plate dielectric barrier discharge plasma reactor
    Guo, YF
    Ye, DQ
    Chen, KF
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2006, 18 (02) : 276 - 280
  • [32] Influence of balance gas mixture on decomposition of dimethyl sulfide in a wire-cylinder pulse corona reactor
    Chen, Jie
    Su, Qingfa
    Pan, Hua
    Wei, Jianwen
    Zhang, Xuming
    Shi, Yao
    [J]. CHEMOSPHERE, 2009, 75 (02) : 261 - 265
  • [33] An analysis of a wire-plate electrostatic precipitator
    Zhang, XR
    Wang, LZ
    Zhu, KQ
    [J]. JOURNAL OF AEROSOL SCIENCE, 2002, 33 (11) : 1595 - 1600
  • [34] Self-excited oscillation of a taut string in a wire-plate electrode system with a corona discharge
    Itoh, Yoshiaki
    Yoshizawa, Masatsugu
    Ikejiri, Noritaka
    Kumashiro, Takashi
    [J]. Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, Vol 1, Pts A-C, 2005, : 1575 - 1583
  • [36] Decomposition of dichloromethane in a wire-in-tube pulsed corona reactor
    Huang, L
    Nakajo, K
    Ozawa, S
    Matsuda, H
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (06) : 1276 - 1281
  • [37] Evaluation of the performance of a wire-plate electrostatic precipitator
    Nóbrega, SW
    Arnosti, S
    Coury, JR
    [J]. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2001, 18 (03) : 313 - 325
  • [38] Geometrical effects of the discharge system on the corona discharge and chemically active species generated in wire-cylinder and wire-plate reactors
    Kim, Y
    Park, JM
    Hong, SH
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 44 (06) : 1458 - 1467
  • [39] Corona discharge and ozone generation characteristics of a wire-plate discharge system with a glass-fiber layer
    Jung, Jae-Seung
    Moon, Jae-Duk
    [J]. JOURNAL OF ELECTROSTATICS, 2008, 66 (5-6) : 335 - 341
  • [40] Effective corona discharge and ozone generation from a wire-plate discharge system with a slit dielectric barrier
    Moon, Jae-Duk
    Jung, Jae-Seung
    [J]. JOURNAL OF ELECTROSTATICS, 2007, 65 (10-11) : 660 - 666