The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants

被引:14
|
作者
De Pauw, Kevin [1 ,2 ]
Cherelle, Pierre [2 ]
Roelands, Bart [1 ]
Lefeber, Dirk [2 ,3 ]
Meeusen, Romain [1 ,3 ]
机构
[1] Vrije Univ Brussel, Res Grp Human Physiol, Fac Phys Educ & Phys Therapy, Brussels, Belgium
[2] Vrije Univ Brussel, Dept Mech Engn, Fac Sci Appl, Brussels, Belgium
[3] Vrije Univ Brussel, Strateg Res Program, Brussels, Belgium
关键词
Ankle prosthesis; treadmill walking; Ankle Mimicking Prosthetic foot; intensity of effort; gait; prosthetic feet; prosthetics; QUEBEC USER EVALUATION; ASSISTIVE TECHNOLOGY; TRANSTIBIAL AMPUTATION; SATISFACTION; APPLICABILITY; RELIABILITY; VALIDATION; VALIDITY; AMPUTEES;
D O I
10.1177/0309364618767141
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Evaluating the effectiveness of a novel prosthetic device during walking is an important step in product development. Objective: To investigate the efficacy of a novel quasi-passive ankle prosthetic device, Ankle Mimicking Prosthetic Foot 4.0, during walking at different speeds, using physiological determinants in transtibial and transfemoral amputees. Study design: Nonrandomized crossover design for amputees. Methods: Six able-bodied subjects, six unilateral transtibial amputees, and six unilateral transfemoral amputees underwent a 6-min walk test at normal speed, followed by series of 2-min walking at slow, normal, and fast speeds. The intensity of effort and subjective measures were determined. Amputees performed all walking tests on a treadmill with current and novel prostheses. Shapiro-Wilk normality tests and parametric and nonparametric tests were conducted (p<0.05). Results: Compared to able-bodied individuals, the rating of perceived exertion levels were significantly elevated in transtibial and transfemoral amputees for both prostheses (p0.016). Compared to able-bodied individuals transfemoral amputees also showed significantly elevated heart rate for both prostheses at normal speed (p0.043). Within-group comparisons demonstrated that walking with Ankle Mimicking Prosthetic Foot significantly increased the heart rate in transfemoral amputees and transtibial compared to current prosthesis (p=0.002). Furthermore, transfemoral amputees reached a significantly higher rating of perceived exertion levels. Conclusion: Intensity of effort during walking with Ankle Mimicking Prosthetic Foot is higher compared to current prostheses. Clinical relevance Ankle Mimicking Prosthetic Foot 4.0 is a novel quasi-passive ankle prosthesis with state-of-the-art technological parts. Subjective measures show the importance of this technology, but the intensity of effort during walking still remains higher compared to current passive prostheses, especially in transfemoral amputees.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 50 条
  • [21] Ankle and foot mechanics in individuals with chronic ankle instability during shod walking and barefoot walking: A cross-sectional study
    Abdelraouf, Osama Ragaa
    Abdel-aziem, Amr Almaz
    CHINESE JOURNAL OF TRAUMATOLOGY, 2021, 24 (03) : 174 - 179
  • [22] Passive hydraulic prosthetic foot to improve the push-off during walking
    Naseri, Amirreza
    Moghaddam, Majid Mohammadi
    Grimmer, Martin
    Sharbafi, Maziar Ahmad
    MECHANISM AND MACHINE THEORY, 2022, 172
  • [23] Paediatric patients with blood-induced ankle joint arthritis demonstrate physiological foot joint mechanics and energetics during walking
    Tijskens, Dorien
    Lobet, Sebastien
    Eerdekens, Maarten
    Peerlinck, Kathelijne
    Hermans, Cedric
    Van Damme, An
    Staes, Filip
    Deschamps, Kevin
    HAEMOPHILIA, 2020, 26 (05) : 907 - 915
  • [24] Efficacy of ankle foot orthoses types on walking in children with cerebral palsy: A systematic review
    Aboutorabi, Atefeh
    Arazpour, Mokhtar
    Bani, Monireh Ahmadi
    Saeedi, Hassan
    Head, John S.
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2017, 60 (06) : 393 - 402
  • [25] Biomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking
    Chung, Chloe L.
    DiAngelo, Denis J.
    Powell, Douglas W.
    Paquette, Max R.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [26] Classification of Ankle Joint Stiffness during Walking to Determine the Use of Ankle Foot Orthosis after Stroke
    Sekiguchi, Yusuke
    Honda, Keita
    Owaki, Dai
    Izumi, Shin-Ichi
    BRAIN SCIENCES, 2021, 11 (11)
  • [27] The biomechanical behaviour of ankle and foot joints during walking with shoes in patients with haemophilia
    Eerdekens, Maarten
    Peerlinck, Kathelijne
    Staes, Filip
    Hermans, Cedric
    Lobet, Sebastien
    Deschamps, Kevin
    HAEMOPHILIA, 2020, 26 (04) : 726 - 734
  • [28] Enhancing performance during inclined loaded walking with a powered ankle–foot exoskeleton
    Samuel Galle
    Philippe Malcolm
    Wim Derave
    Dirk De Clercq
    European Journal of Applied Physiology, 2014, 114 : 2341 - 2351
  • [29] EXERCISE MODERATION OF FOOT FUNCTION DURING WALKING WITH A REUSABLE SEMIRIGID ANKLE ORTHOSIS
    HAMILL, J
    MORIN, G
    CLARKSON, PM
    ANDRES, RO
    CLINICAL BIOMECHANICS, 1988, 3 (03) : 153 - 158
  • [30] Effects of age and speed on the ankle–foot system’s power during walking
    Lucas Santana da Silva
    Reginaldo Kisho Fukuchi
    Renato Naville Watanabe
    Claudiane Arakaki Fukuchi
    Marcos Duarte
    Scientific Reports, 10