The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants

被引:14
|
作者
De Pauw, Kevin [1 ,2 ]
Cherelle, Pierre [2 ]
Roelands, Bart [1 ]
Lefeber, Dirk [2 ,3 ]
Meeusen, Romain [1 ,3 ]
机构
[1] Vrije Univ Brussel, Res Grp Human Physiol, Fac Phys Educ & Phys Therapy, Brussels, Belgium
[2] Vrije Univ Brussel, Dept Mech Engn, Fac Sci Appl, Brussels, Belgium
[3] Vrije Univ Brussel, Strateg Res Program, Brussels, Belgium
关键词
Ankle prosthesis; treadmill walking; Ankle Mimicking Prosthetic foot; intensity of effort; gait; prosthetic feet; prosthetics; QUEBEC USER EVALUATION; ASSISTIVE TECHNOLOGY; TRANSTIBIAL AMPUTATION; SATISFACTION; APPLICABILITY; RELIABILITY; VALIDATION; VALIDITY; AMPUTEES;
D O I
10.1177/0309364618767141
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Evaluating the effectiveness of a novel prosthetic device during walking is an important step in product development. Objective: To investigate the efficacy of a novel quasi-passive ankle prosthetic device, Ankle Mimicking Prosthetic Foot 4.0, during walking at different speeds, using physiological determinants in transtibial and transfemoral amputees. Study design: Nonrandomized crossover design for amputees. Methods: Six able-bodied subjects, six unilateral transtibial amputees, and six unilateral transfemoral amputees underwent a 6-min walk test at normal speed, followed by series of 2-min walking at slow, normal, and fast speeds. The intensity of effort and subjective measures were determined. Amputees performed all walking tests on a treadmill with current and novel prostheses. Shapiro-Wilk normality tests and parametric and nonparametric tests were conducted (p<0.05). Results: Compared to able-bodied individuals, the rating of perceived exertion levels were significantly elevated in transtibial and transfemoral amputees for both prostheses (p0.016). Compared to able-bodied individuals transfemoral amputees also showed significantly elevated heart rate for both prostheses at normal speed (p0.043). Within-group comparisons demonstrated that walking with Ankle Mimicking Prosthetic Foot significantly increased the heart rate in transfemoral amputees and transtibial compared to current prosthesis (p=0.002). Furthermore, transfemoral amputees reached a significantly higher rating of perceived exertion levels. Conclusion: Intensity of effort during walking with Ankle Mimicking Prosthetic Foot is higher compared to current prostheses. Clinical relevance Ankle Mimicking Prosthetic Foot 4.0 is a novel quasi-passive ankle prosthesis with state-of-the-art technological parts. Subjective measures show the importance of this technology, but the intensity of effort during walking still remains higher compared to current passive prostheses, especially in transfemoral amputees.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 50 条
  • [1] Evaluation of a Powered Ankle-Foot Prosthetic System During Walking
    Ferris, Abbie E.
    Aldridge, Jennifer M.
    Rabago, Christopher A.
    Wilken, Jason M.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 1911 - 1918
  • [2] Design and Validation of the Ankle Mimicking Prosthetic (AMP-) Foot 2.0
    Cherelle, Pierre
    Grosu, Victor
    Matthys, Arnout
    Vanderborght, Bram
    Lefeber, Dirk
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2014, 22 (01) : 138 - 148
  • [3] Development of a Prosthetic Ankle-Foot and Its Slope-Walking Experiments
    Li, Chengqiu
    Morimot, Shoji
    Furusho, Junji
    Kikuch, Takehito
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 1806 - +
  • [4] Prosthetic Ankle-Foot Mechanism Capable of Automatic Adaptation to the Walking Surface
    Williams, Ryan J.
    Hansen, Andrew H.
    Gard, Steven A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03):
  • [5] Comparison between SACH foot and a new multiaxial prosthetic foot during walking in hypomobile transtibial amputees: physiological responses and functional assessment
    Delussu, Anna S.
    Paradisi, Francesco
    Brunelli, Stefano
    Pellegrini, Roberto
    Zenardi, Daniele
    Traballesi, Marco
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2016, 52 (03) : 304 - 309
  • [6] DYNAMIC BIOMECHANICS OF THE NORMAL FOOT AND ANKLE DURING WALKING AND RUNNING
    RODGERS, MM
    PHYSICAL THERAPY, 1988, 68 (12): : 1822 - 1830
  • [7] Force in the Achilles Tendon During Walking With Ankle Foot Orthosis
    Froberg, Asa
    Komi, Paavo
    Ishikawa, Masaki
    Movin, Tomas
    Arndt, Anton
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (06): : 1200 - 1207
  • [8] Prosthesis foot that has an action of ankle joint during walking
    Takahama, Itsurou
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 1994, 60 (05): : 647 - 651
  • [9] Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic foot
    Heitzmann, Daniel W. W.
    Salami, Firooz
    De Asha, Alan R.
    Block, Julia
    Putz, Cornelia
    Wolf, Sebastian, I
    Alimusaj, Merkur
    GAIT & POSTURE, 2018, 64 : 174 - 180
  • [10] Deformable foot orthoses redistribute power from the ankle to the distal foot during walking
    Henderson, Adrienne
    Hulcher, Thomas
    Koller, Corey
    Bruening, Dustin
    Arch, Elisa
    JOURNAL OF BIOMECHANICS, 2021, 128