Advanced control of condensing temperature for enhancing the operating efficiency of air-cooled chillers

被引:20
|
作者
Yu, FW [1 ]
Chan, KT [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
air-cooled chiller; condenser fans; condensing temperature; efficiency;
D O I
10.1016/j.buildenv.2004.08.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-cooled chillers are commonly used to provide cooling energy in commercial buildings in the subtropical climate. These chillers have long been considered inefficient because they operate under head pressure control where the condensing temperature is kept high in the refrigeration cycle. This paper considers a novel method to strategically lower the condensing temperature to enhance chiller efficiency at any outdoor temperature. An experiment is carried out on an air-cooled reciprocating chiller to confirm that an electronic expansion valve enables refrigerant to be adequately fed into the evaporator in all operating conditions, even when the condensing temperature falls to around 20 degreesC. By enhancing the heat rejection airflow of the condenser, both the condensing temperature and chiller power can decrease considerably with less fluctuation. According to the algorithm of staging condenser fans, this enhancement corresponds to resetting the set point of the condensing temperature based on any outdoor temperature. The potential and benefits of implementing this reset strategy are discussed. (C) 2004 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:727 / 737
页数:11
相关论文
共 50 条
  • [41] Strategies for IECC 2021 Compliance in Hot Climates With Air-Cooled Chillers
    Quirk, David
    Yassaghi, Hamed
    Davidson, Tom
    Popovich, Chris
    ASHRAE Journal, 2024, 66 (05) : 16 - 22
  • [42] Critique of the design and operation of sustainable air-cooled chillers in commercial buildings
    Yu, F.W.
    Chan, K.T.
    Sit, R.K.Y.
    Yang, J.
    Energy Engineering: Journal of the Association of Energy Engineering, 2015, 112 (03): : 55 - 79
  • [43] The Impact of Barometric Pressure, Temperature, and Operating Temperature Difference on Air-Cooled Data Centers
    Dunnavant, Keith
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 176 - 187
  • [44] Analysis of Condensing Temperature Set Point of Air-Cooled Refrigeration System with an Electronic Expansion Valve
    Zhou Zhigang
    Zhang Hua
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 7718 - 7722
  • [45] Heat Treatment Structure Design for Air-cooled PEMFC Operating at Elevated Temperature
    Yang, Daijun
    Zheng, Xiaoliang
    Lia, Bing
    Zhang, Hao
    Ma, Jianxin
    BATTERIES AND ENERGY TECHNOLOGY (GENERAL)- 219TH ECS MEETING, 2011, 35 (32): : 181 - 189
  • [46] Improved condenser design and condenser-fan operation for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED ENERGY, 2006, 83 (06) : 628 - 648
  • [47] Evaporative cooling technologies for air-cooled chillers for building energy performance improvement
    Yu, F. W.
    Chan, K. T.
    Yang, J.
    Sit, R. K. Y.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2016, 10 (01) : 10 - 19
  • [48] Performance enhancement of air-cooled chillers with water mist: Experimental and analytical investigation
    Yang, Jia
    Chan, K. T.
    Wu, Xiangsheng
    Yang, Xiaofeng
    Zhang, Hongyu
    APPLIED THERMAL ENGINEERING, 2012, 40 : 114 - 120
  • [49] EXPERIMENTAL STUDIES OF ENERGY PERFORMANCE OF AIR-COOLED CHILLERS WITH WATER MIST SYSTEM
    Yang, Jia
    Chan, Kwok-tai
    Wu, Xiang-sheng
    PROCEEDINGS OF THE SECOND INTERNATIONAL POSTGRADUATE CONFERENCE ON INFRASTRUCTURE AND ENVIRONMENT, VOL 1, 2010, : 21 - 30
  • [50] Microchannel heat exchangers for charge minimization in air-cooled ammonia condensers and chillers
    Hrnjak, Pega
    Litch, Andy D.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (04): : 658 - 668