Safety Study of Transcutaneous Focused Ultrasound for Non-Invasive Skin Tightening in Asians

被引:74
|
作者
Chan, Nicola P. Y. [1 ]
Shek, Samantha Y. N. [1 ]
Yu, Carol S. [2 ]
Ho, Stephanie G. Y. [1 ]
Yeung, Chi K. [1 ]
Chan, Henry H. L. [1 ,3 ]
机构
[1] Univ Hong Kong, Div Dermatol, Dept Med, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Inst Eye, Hong Kong, Hong Kong, Peoples R China
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Wellman Ctr Photomed, Boston, MA USA
关键词
Asian; non-ablative; safety; tightening; ultrasound; FACIAL SKIN; RADIOFREQUENCY TREATMENT; BIPOLAR RADIOFREQUENCY; INFRARED DEVICE; MULTIPLE-PASS; FACE LIFT; REJUVENATION; TECHNOLOGY; LAXITY; ALGORITHM;
D O I
10.1002/lsm.21070
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: Transcutaneous intense focused ultrasound has emerged as a novel technology for non-invasive skin tightening. The objective of this study was to evaluate the safety profile of a transcutaneous focused ultrasound device for the treatment of facial skin laxity in Asians. Materials and Methods: The patients received one to three full-face treatments with the transcutaneous focused ultrasound device. Three transducers (7.0 MHz, 3.0 mm focal depth; 7.0 MHz, 4.5 mm focal depth; 4.0 MHz, 4.5 mm focal depth) were used to deliver a single pass of microthermal coagulation zones without any topical anesthetics. Standardized photos were taken at baseline and at each follow-up with the Canfield Visia CR system (R) and were assessed by two independent physicians. Adverse effects were assessed up to 6 months post treatment. Subjective assessments in terms of pain and tolerability were also evaluated with patient questionnaires. Results: Forty nine Chinese patients (skin types III-IV, mean age 53.3) completed a total of 68 treatment sessions. Transient erythema and edema were seen in the majority of patients. Focal bruising was present in up to 25% of treatment sessions. Two cases of post-inflammatory hyperpigmentation were seen on the forehead at 1-month post-treatment. One patient experienced focal twitching over the lower eyelid at 1-month follow-up, which was clinically consistent with hemifacial spasm and was unrelated to the ultrasound device. The degree of pain during treatment was recorded as severe in 54.4% of treatment sessions. Conclusions: Transcutaneous intense focused ultrasound appeared to be safe for non-invasive facial skin tightening in Asians. Adverse events were mild and transient. Pain control during treatment should be optimized. No serious permanent or delayed side effects were noted up to 6 months post treatment. Lasers Surg. Med. 43:366-375, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:366 / 375
页数:10
相关论文
共 50 条
  • [21] Transcranial focused ultrasound: a new tool for non-invasive neuromodulation
    Fini, Maria
    Tyler, William J.
    INTERNATIONAL REVIEW OF PSYCHIATRY, 2017, 29 (02) : 168 - 177
  • [22] Efficacy and Safety of Non-invasive Renal Denervation Study Using Externally Delivered Focused Ultrasound in Severe Resistant Hypertension
    Schmieder, Roland E.
    Ormiston, John A.
    Neuzil, Petr
    Starek, Zdenek
    Kay, Patrick
    Dawood, Omar
    Anderson, Thomas L.
    Gertner, Michael
    White, William B.
    CIRCULATION, 2015, 132
  • [23] Intense focused ultrasound for neck and lower face skin tightening a prospective study
    Friedman, Or
    Isman, Gila
    Koren, Amir
    Shoshany, Hadas
    Sprecher, Eli
    Artzi, Ofir
    JOURNAL OF COSMETIC DERMATOLOGY, 2020, 19 (04) : 850 - 854
  • [24] High-intensity focused ultrasound: a revolution in non-invasive ultrasound treatment?
    Yagel, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (03) : 216 - 217
  • [25] Technical and safety considerations for High Intensity Focused Ultrasound (HIFU) non-invasive placental vascular occlusion
    Shaw, C. J.
    Rivens, I
    Civale, J.
    Botting, K. J.
    Giussani, D. A.
    ter Haar, G.
    Lees, C. C.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 5 - 5
  • [26] Nonsurgical tightening of knees skin with intense focused ultrasound: Ultherapy
    Macedo, Otavio
    Matayoshi, Luciana
    Matsumoto, Luciana
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2014, 70 (05) : AB193 - AB193
  • [27] Safety and efficacy of transcutaneous ultrasound for forehead, cheek and neck tissue tightening
    Alam, Murad
    White, Lucile
    Majzoub, Rania
    Martin, Nicolle
    Yoo, Simon
    LASERS IN SURGERY AND MEDICINE, 2007, : 18 - 18
  • [28] Retrospective cohort study on the efficacy and safety of high-intensity focused ultrasound in non-invasive treatment of uterine leiomyomas and adenomyosis
    Su, Zhan
    Liu, Sha
    Wang, Jiulan
    Jin, Fengying
    Peng, Youjin
    Wen, Junjie
    ABDOMINAL RADIOLOGY, 2025,
  • [29] A novel non-invasive radiofrequency dermal heating device for skin tightening of the face and neck
    Nelson, Andrew A.
    Beynet, David
    Lask, Gary P.
    JOURNAL OF COSMETIC AND LASER THERAPY, 2015, 17 (06) : 307 - 312
  • [30] Non-invasive cardiac pacing with image-guided focused ultrasound
    Marquet, Fabrice
    Bour, Pierre
    Vaillant, Fanny
    Amraoui, Sana
    Dubois, Remi
    Ritter, Philippe
    Haissaguerre, Michel
    Hocini, Meleze
    Bernus, Olivier
    Quesson, Bruno
    SCIENTIFIC REPORTS, 2016, 6