Programmable LED-based integrating sphere light source for wide-field fluorescence microscopy

被引:9
|
作者
ul Rehman, Aziz [1 ,2 ,3 ]
Anwer, Ayad G. [1 ,2 ]
Goldys, Ewa M. [1 ,2 ]
机构
[1] Macquarie Univ, ARC Ctr Excellence Nanoscale Biophoton, Sydney, NSW 2109, Australia
[2] Macquarie Univ, Dept Phys & Astron, Sydney, NSW 2109, Australia
[3] Natl Inst Lasers & Optron, Biophoton Lab, Lehtrar Rd, Islamabad 45650, Pakistan
基金
澳大利亚研究理事会;
关键词
Integrating sphere; Fluorescence microscopy; BV2Cells; Spectral spatial profile; Low noise CMOS camera; SPECTROSCOPY; TISSUES;
D O I
10.1016/j.pdpdt.2017.10.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Wide-field fluorescence microscopy commonly uses a mercury lamp, which has limited spectral capabilities. We designed and built a programmable integrating sphere light (PISL) source which consists of nine LEDs, light collecting optics, a commercially available integrating sphere and a baffle. The PISL source is tuneable in the range 365-490 nm with a uniform spatial profile and a sufficient power at the objective to carry out spectral imaging. We retrofitted a standard fluorescence inverted microscope DM IRB (Leica) with a PISL source by mounting it together with a highly sensitive low- noise CMOS camera. The capabilities of the setup have been demonstrated by carrying out multispectral autofluorescence imaging of live BV2 cells.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 50 条
  • [41] Doubling the lateral resolution of wide-field fluorescence microscopy using structured illumination
    Gustafsson, MGL
    Agard, DA
    Sedat, JW
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION PROCESSING VII, 2000, 3919 : 141 - 150
  • [42] Accurate quantitative wide-field fluorescence microscopy of 3-D spheroids
    Leary, Elizabeth
    Rhee, Claire
    Wilks, Benjamin
    Morgan, Jeffrey R.
    BIOTECHNIQUES, 2016, 61 (05) : 237 - 247
  • [43] CELL-BASED CYTOMETRY USING WIDE-FIELD MICROSCOPY
    Malkusch, W.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B (06) : 384 - 384
  • [44] Fluorescence errors in integrating sphere measurements of remote phosphor type LED light sources
    Keppens, A.
    Zong, Y.
    Podobedov, V. B.
    Nadal, M. E.
    Hanselaer, P.
    Ohno, Y.
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VII, 2011, 8082
  • [45] Performance of LED-Based Fluorescence Microscopy to Diagnose Tuberculosis in a Peripheral Health Centre in Nairobi
    Bonnet, Maryline
    Gagnidze, Laramie
    Githui, Willie
    Guerin, Philippe Jean
    Bonte, Laurence
    Varaine, Francis
    Ramsay, Andrew
    PLOS ONE, 2011, 6 (02):
  • [46] Wide-field coherent anti-Stokes Raman scattering microscopy based on picosecond supercontinuum source
    Shen, Yujie
    Wang, Jizhou
    Wang, Kai
    Sokolov, Alexei, V
    Scully, Marlan O.
    APL PHOTONICS, 2018, 3 (11)
  • [47] Digital scanned laser light-sheet fluorescence lifetime microscopy with wide-field time-gated imaging
    Li, R.
    Liu, A.
    Wu, T.
    Xiao, W.
    Tang, Li
    Chen Lingling
    JOURNAL OF MICROSCOPY, 2020, 279 (01) : 69 - 76
  • [48] Impact of the LED-based light source working regime on the degradation of polymethyl methacrylate
    Sikora, A.
    Tomczuk, K.
    LIGHTING RESEARCH & TECHNOLOGY, 2020, 52 (01) : 94 - 105
  • [49] Temperature-stable LED-based light source without temperature control
    Bosiljevac, M.
    Babic, D.
    Sipus, Zvonimir
    PHOTONIC INSTRUMENTATION ENGINEERING III, 2016, 9754
  • [50] New LED-based high-brightness incoherent light source in the SWIR
    Pichon, Pierre
    Blanchot, Jean-Philippe
    Balembois, Francois
    Georges, Patrick
    OPTICS EXPRESS, 2018, 26 (07): : 9353 - 9362