Dynamic Characteristic Analysis of Centrifugal Pump Impeller Based on Fluid-Solid Coupling

被引:8
|
作者
Li, Yufang [1 ]
Su, Hongli [1 ]
Wang, Yanwei [1 ]
Jiang, Wei [1 ]
Zhu, Qipei [1 ,2 ]
机构
[1] Wuhan Inst Technol, Key Lab Chem Equipment Enhancement & Intrins Safe, Wuhan 430205, Peoples R China
[2] Hangzhou Hikvis Digital Technol Co Ltd, Hangzhou 310052, Peoples R China
关键词
centrifugal pump; start up process; unsteady flow; radial force; fluid-solid coupling; CAVITATION;
D O I
10.3390/jmse10070880
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Purpose: Centrifugal pumps are prone to vibration problems during operation due to poor dynamic characteristics of its impellers that serve as the only running parts of such devices; the dynamic characteristics of the impeller during operation are the main reasons for the vibration of the centrifugal pump. Therefore, it is important to study the internal fluid flow and its influence on the dynamic characteristics of the pump impeller and to explore the causes of vibration during the transient start-up process. The understanding of such phenomena may lead to better design of such impellers. Methods: The geometry of the flow channel inside the centrifugal pump is established using Creo 4.0 software (American PTC company). The internal fluid flow computer simulation is carried out using Flomaster V9 software (UK Flowmaster company) to obtain the variation law of speed and flow during the start-up of the centrifugal pump, which is loaded into the simulation calculation of the centrifugal pump. The variation of speed and flow during the start-up process was further processed using the fluid-structure coupling method, and the structural vibration characteristics of the impeller under transient radial force are obtained by harmonic response analysis. Results: During the starting process of the centrifugal pump, the speed and flow first increased sharply and then decreased until reaching a stable process. During this period, the impeller vibration changed sharply; the overall vibration amplitude increased and fluctuated stably at the amplitude of 0.01 mm. In the unsteady numerical simulation of the centrifugal pump, the radial force on the impeller changes periodically. The time domain signal is transformed into a frequency domain signal, and the fundamental frequency of the impeller and the passing frequency of the blade are 101.67 Hz and 610 Hz, respectively. Conclusions: The radial force is the main cause of impeller vibration, and the transient radial force has the least dynamic impact on the impeller structure under the design condition and has a relatively large impact under the off-design condition. In order to ensure the stable operation of the centrifugal pump, it is necessary to avoid the centrifugal pump working under the non-standard flow condition, especially the small flow condition.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Study on dynamic characteristic analysis of vehicle shock absorbers based on bidirectional fluid-solid coupling
    Chen, Qiping
    Xu, Zhihui
    Wu, Mingming
    Xiao, Yuan
    Shao, Hao
    [J]. ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2021, 15 (01) : 426 - 436
  • [2] Fluid-solid coupling field analysis of centrifugal fan based on nonlinear dynamics
    Luo, Chenxu
    Jing, Shuangxi
    Han, Xiaoming
    Leng, Junfa
    [J]. JOURNAL OF VIBROENGINEERING, 2017, 19 (07) : 5473 - 5481
  • [3] Dynamic stress analysis of sewage centrifugal pump impeller based on two-way coupling method
    Ji Pei
    Shouqi Yuan
    Jianping Yuan
    [J]. Chinese Journal of Mechanical Engineering, 2014, 27 : 369 - 375
  • [4] Dynamic Stress Analysis of Sewage Centrifugal Pump Impeller Based on Two-way Coupling Method
    PEI Ji
    YUAN Shouqi
    YUAN Jianping
    [J]. Chinese Journal of Mechanical Engineering, 2014, (02) : 369 - 375
  • [5] Dynamic Stress Analysis of Sewage Centrifugal Pump Impeller Based on Two-way Coupling Method
    PEI Ji
    YUAN Shouqi
    YUAN Jianping
    [J]. Chinese Journal of Mechanical Engineering., 2014, 27 (02) - 375
  • [6] Dynamic Stress Analysis of Sewage Centrifugal Pump Impeller Based on Two-way Coupling Method
    Pei Ji
    Yuan Shouqi
    Yuan Jianping
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (02) : 369 - 375
  • [7] Dynamic characteristics analysis of RCP impeller based on fluid-thermal-solid coupling
    Fu, Qiang
    Wang, Dandan
    Liu, Xiangsong
    Zhao, Yun
    Zhu, Rongsheng
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2024, 428
  • [8] Analysis of Fluid-Solid coupling heat transfer characteristics of hydrogen circulating pump
    Zhai, Huanle
    Li, Wei
    Li, Jiwei
    Ji, Leilei
    Xu, Yuanfeng
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2024, 107
  • [9] Tip cooling injection characteristic of turbine blade based on fluid-solid coupling method
    Zhang, Yunsong
    Liu, Yongbao
    Li, Yujie
    He, Xing
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2020, 52 (07): : 186 - 192
  • [10] The Analysis that Fluid-Solid and Heating-Solid Coupling of Seeker Based on Workbench
    Zhang, Nan
    Yang, Chunlei
    Li, Yanhui
    Jia, Hongguang
    [J]. AEIT 2012: 2012 2ND INTERNATIONAL CONFERENCE ON AEROSPACE ENGINEERING AND INFORMATION TECHNOLOGY, VOL 2, 2012, : 106 - 111