Measurement of the 109Cd half-life

被引:12
|
作者
Van Ammel, R. [1 ]
Pomme, S. [1 ]
Paepen, J. [1 ]
Sibbens, G. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
Half-life; Cd-109; Radionuclide metrology; Nuclear data; Quality control; DEAD-TIME; LIVES; RADIONUCLIDES; UNCERTAINTY; CO-57;
D O I
10.1016/j.apradiso.2011.01.020
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The half-life of Cd-109 was measured by following the decay of sources from a radiochemically pure solution with two different measuring systems: an ionisation chamber and a high-purity germanium (HPGe) detector. The measurements were performed over a period of 3.6 years, i.e. about 2.8 half-lives of Cd-109. The resulting half-life values and detailed uncertainty budgets (k=1) are presented for both systems. The result obtained with the ionisation chamber. 462.36 (33) days, and the one obtained with the HPGe detector, 461.92 (76) days, are mutually consistent. The weighted mean of our measured values. T-1/2(Cd-109)= 462.29 (30)days. is consistent with the currently recommended values of 461.4 (12) days (Schonfeld and Dersch, 2004; IAEA, 2007) and 462.0 (3) days (Xiaolong et al., 2010). From a set of selected experimental values published after 1970. a "partially weighted mean" (Pomme and Spasova, 2008) of T-1/2(Cd-109)=462.36 (39) days was calculated. More measurements are needed to resolve the discrepancies among literature data and to reduce the final uncertainty on the Cd-109 half-life. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:785 / 789
页数:5
相关论文
共 50 条
  • [21] HALF-LIFE MEASUREMENT OF CF-252
    MIJNHEER, BJ
    VANDENHA.E
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (03): : 185 - 187
  • [22] MEASUREMENT OF THE HALF-LIFE OF F-20
    WANG, TF
    BOYD, RN
    MATHEWS, GJ
    ROBERTS, ML
    SALE, KE
    FARRELL, MM
    ISLAM, MS
    KOLNICKI, GW
    NUCLEAR PHYSICS A, 1992, 536 (01) : 159 - 167
  • [23] MEASUREMENT OF THE HALF-LIFE OF CA-45
    LOSARCOS, JM
    RODRIGUEZ, L
    ROTETA, M
    GARCIATORANO, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 164 - 167
  • [24] Half-life measurement of 55Fe
    Van Ammel, R.
    Pomme, S.
    Sibbens, G.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1412 - 1416
  • [25] Picosecond lifetime measurements in 109Cd and 110Cd
    Harissopulos, S
    Dewald, A
    Gelberg, A
    Zell, KO
    von Brentano, P
    Kern, J
    NUCLEAR PHYSICS A, 2001, 683 : 157 - 181
  • [26] Measurement of the 175Hf half-life
    Kmak, K. N.
    Neupane, S.
    Kolos, K.
    Despotopulos, J. D.
    Sammis, B. N.
    Wooddy, T.
    Scielzo, N. D.
    PHYSICAL REVIEW C, 2025, 111 (02)
  • [27] Precision measurement of the half-life of Be-7
    Jaeger, M
    Wilmes, S
    Kolle, V
    Staudt, G
    Mohr, P
    PHYSICAL REVIEW C, 1996, 54 (01): : 423 - 424
  • [28] Measurement of the half-life of 68Ga
    Garcia-Torano, Eduardo
    Peyres Medina, Virginia
    Romero, Eduardo
    Roteta, Miguel
    APPLIED RADIATION AND ISOTOPES, 2014, 87 : 122 - 125
  • [29] MEASUREMENT OF THE HALF-LIFE OF CO-56
    ALBURGER, DE
    WESSELBORG, C
    PHYSICAL REVIEW C, 1990, 42 (06): : 2728 - 2729
  • [30] Measurement of the 177Lu half-life
    Pomme, S.
    Paepen, J.
    Altzitzoglou, T.
    Van Ammel, R.
    Yeltepe, E.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (09) : 1267 - 1273