HJ-1A THERMAL INFRARED BAND CROSS-CALIBRATION AND VALIDATION

被引:0
|
作者
Li, Jiaguo [1 ,2 ,3 ]
Gu, Xingfa [1 ,2 ]
Zhu, Li [5 ]
Yu, Tao [1 ,2 ]
Li, Xiaoying [1 ,2 ]
Zhang, Yuxiang [4 ]
Gao, Hailiang [1 ,2 ,3 ]
Gong, Hui [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, IRSA, State Key Lab Remote Sensing, Beijing 100101, Peoples R China
[2] Ctr Natl Spaceborn Demonstrat, Beijing 100101, Peoples R China
[3] Grad Univ, Chinese Acad Sci, Beijing 100039, Peoples R China
[4] Natl Satellite Meteorol Ctr, Beijing 100081, Peoples R China
[5] China Environm Monitoring Ctr, Beijing 100029, Peoples R China
关键词
Hi-IA; cross-calibration; validation;
D O I
暂无
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
HJ-1A satellite has been lunched in September, 2008. It is calibration and validation that the fundamental of quantitative utilization of HJ-1A IRS imagery. HJ-1A has only one channel in thermal infrared band, compared to MODIS sensor, which has two channels accordingly The key process of cross-calibration is band match, so this paper uses the MODIS SST product retrieval algorithm as reference for the difference of HJ-1A and MODIS thermal infrared channels characters. TIGR database were used as input parameters into radiative transfer mode Modtran4.0 to obtain band match coefficients by regression analysis. Number 711 similar to 1064 datum in TIGR database representing mid-latitude winter were chose according to the selected image's date Research demonstrates that cross-calibration method is effective to HJ-1A thermal infrared channel 4.
引用
收藏
页码:2167 / +
页数:2
相关论文
共 50 条
  • [31] Cross calibration of GF-1 satellite wide field of view sensor with Landsat 8 OLI and HJ-1A HSI
    Liu, Li
    Gao, Hailiang
    Pan, Zhiqiang
    Gu, Xingfa
    Han, Qijin
    Zhang, Xuewen
    JOURNAL OF APPLIED REMOTE SENSING, 2018, 12
  • [32] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    Wang Chao
    Wu YunZhao
    Shi RunHe
    Gao Wei
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2013, 56 (11) : 2216 - 2225
  • [33] Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers
    Doelling, David R.
    Haney, Conor O.
    Bhatt, Rajendra
    Scarino, Benjamin R.
    Gopalan, Arun
    Khakurel, Prathana
    EARTH OBSERVING SYSTEMS XXVII, 2022, 12232
  • [34] Cross-calibration experiment of airborne L-band polarimetric SAR
    Wakabayashi, H
    Tadono, T
    Matsuoka, M
    Matsuoka, T
    Shimada, M
    Uratsuka, S
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 423 - 425
  • [35] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    Chao Wang
    YunZhao Wu
    RunHe Shi
    Wei Gao
    Science China Physics, Mechanics and Astronomy, 2013, 56 : 2216 - 2225
  • [36] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    WANG Chao
    WU YunZhao
    SHI RunHe
    GAO Wei
    Science China(Physics,Mechanics & Astronomy), 2013, (11) : 2216 - 2225
  • [37] Cross-calibration of MSG1-SEVIRI infrared channels with Terra-MODIS channels
    Jiang, G. -M.
    Li, Z. -L.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2009, 30 (03) : 753 - 769
  • [38] Orbital Lifetime (2008-2017) Radiometric Calibration and Evaluation of the HJ-1B IRS Thermal Infrared Band
    Liu, Wanyue
    Li, Jiaguo
    Han, Qijin
    Zhu, Li
    Yang, Hongyan
    Cheng, Qiuming
    REMOTE SENSING, 2020, 12 (15)
  • [39] Cross-Calibration of the Himawari-9 Thermal Infrared Data by Applying a Physical Sea Surface Temperature Method
    Kurihara, Yukio
    Kachi, Misako
    IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2024, 17 : 19730 - 19742
  • [40] Radiometric cross-calibration of CBERS-02 IRMSS thermal channel
    National Satellite Meteorology Center, China Meteorological Administration, Beijing 100081, China
    不详
    不详
    不详
    不详
    Hongwai Yu Haomibo Xuebao, 2006, 4 (261-266):