Cerebral MR venography in children: Comparison of 2D time-of-flight and gadolinium-enhanced 3D gradient-echo techniques

被引:36
|
作者
Rollins, N
Ison, C
Reyes, T
Chia, J
机构
[1] Childrens Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[2] Univ Texas, SW Med Ctr, Dallas, TX 75235 USA
[3] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1148/radiol.2353041427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare two-dimensional (2D) time-of-flight cerebral magnetic resonance (MR) venography with gadolinium-enhanced three-dimensional (3D) gradient-echo cerebral MR venography in children. MATERIALS AND METHODS: This investigation had investigational review board approval and was Health Insurance Portability and Accountability Act compliant; parental informed consent was obtained. Thirty-seven patients (20 boys, 17 girls) who ranged in age from 4 days to 15 years underwent 2D and 3D MR venography. Two pediatric neuroradiologists compared the visibility of the superior sagittal, straight, transverse, and sigmoid sinuses and the internal jugular veins on images obtained with the two sequences. RESULTS: In 17 (46%) of the 37 patients, the sequences were equivalent in terms of their depiction of venous anatomy. In 19 (51%) of the 37 patients, 3D MR venography was superior to 2D MR venography. Suboptimal enhancement of veins occurred in one (3%) patient at 3D MR venography. Venous anomalies suggested at 2D MR venography but not present at 3D MR venography included flow gaps in the nondominant transverse sinuses of four patients, unilateral transverse sinus atresia in eight, and a narrowed superior sagittal sinus in two. Two-dimensional MR venography results failed to reveal a persistent falcine sinus associated with straight sinus atresia in one patient and suggested transverse sinus thrombosis in two patients in whom 3D MR venography results were normal. Additionally, the extent of dural thrombosis was overestimated at 2D MR venography in one patient. As compared with 3D MR venography, 2D MR venography failed to reveal sigmoid sinus stenosis in one patient and poorly depicted posterior fossa dural sinus anatomy in two patients with dural arteriovenous fistula. CONCLUSION: Three-dimensional MR venography is often superior to 2D MR venography in the delineation of major cerebral venous structures in children. Most of the artifactual loss of vascular signal seen with the use of 2D MR venography occurred in nondominant transverse sinuses. (c) RSNA 2005
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [21] MRI OF THE PITUITARY-GLAND - SPIN-ECHO 2D OR GRADIENT-ECHO 3D
    REUTHER, G
    BONGARTZ, G
    FAHRENDORF, G
    PETERS, PE
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (03): : 281 - 285
  • [22] Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography
    Boulin, A
    Pierot, L
    RADIOLOGY, 2001, 219 (01) : 108 - 113
  • [23] MR cisternography for trigeminal neuralgia: comparison between gradient-echo and spin echo 3D sequences
    Wamasing, Natnicha
    Watanabe, Hiroshi
    Kuribayashi, Ami
    Imaizumi, Akiko
    Sakamoto, Junichiro
    Tomisato, Hiroshi
    DENTOMAXILLOFACIAL RADIOLOGY, 2025,
  • [24] 3D gadolinium-enhanced MR angiography of the carotid arteries
    Cloft, HJ
    Murphy, KJ
    Prince, MR
    Brunberg, JA
    MAGNETIC RESONANCE IMAGING, 1996, 14 (06) : 593 - 600
  • [25] Comparison of 3D multi-echo gradient-echo and 2D T2* MR sequences for the detection of arterial thrombus in patients with acute stroke
    Jérôme Hodel
    Xavier Leclerc
    Wassef Khaled
    Ruben Tamazyan
    Mathieu Rodallec
    Sophie Gerber
    Raphael Blanc
    Mohamed Benadjaoud
    Oriane Lambert
    Cécile Rabrait
    Mathieu Zuber
    Alain Rahmouni
    Marc Zins
    European Radiology, 2014, 24 : 762 - 769
  • [26] Comparison of 3D multi-echo gradient-echo and 2D T2*MR sequences for the detection of arterial thrombus in patients with acute stroke
    Hodel, Jerome
    Leclerc, Xavier
    Khaled, Wassef
    Tamazyan, Ruben
    Rodallec, Mathieu
    Gerber, Sophie
    Blanc, Raphael
    Benadjaoud, Mohamed
    Lambert, Oriane
    Rabrait, Cecile
    Zuber, Mathieu
    Rahmouni, Alain
    Zins, Marc
    EUROPEAN RADIOLOGY, 2014, 24 (03) : 762 - 769
  • [27] Pulmonary time-of-flight MR angiography at 1.0 T: Comparison between 2D and 3D tone acquisitions
    Laissy, JP
    Assayag, P
    HenryFeugeas, MC
    Tebboune, D
    Berger, JF
    Limot, O
    Falise, B
    Chillon, S
    Valere, PE
    SchoumanClaeys, E
    MAGNETIC RESONANCE IMAGING, 1995, 13 (07) : 949 - 957
  • [28] Comparison of gadolinium-enhanced 3D MRA and 3D reconstructions with spin-echo MRI for coarctation of the aorta
    Yeh, BM
    Reddy, GP
    Yang, M
    Gotway, MB
    Heller, DN
    Higgins, CB
    RADIOLOGY, 2000, 217 : 467 - 467
  • [29] Contrast-enhanced 3D MR angiography of moyamoya disease: Comparison with conventional 3D time-of-flight MR angiography
    Yoon, H
    Shin, H
    Na, D
    Cho, Y
    Han, BK
    RADIOLOGY, 2000, 217 : 429 - 429
  • [30] High-resolution 3D gadolinium-enhanced MR venography in suspected thromboocclusive disease of the chest veins
    Kroencke, TJ
    Taupitz, M
    Hamm, BK
    RADIOLOGY, 2000, 217 : 468 - 468