A Temperature Self-calibrating Torsional Accelerometer with Fully Differential Configuration and Integrated Reference Capacitor

被引:0
|
作者
Xiao, Dingbang [1 ]
Xia, Dewei [1 ]
Li, Qingsong [1 ]
Wu, Yulie [1 ]
Chen, Zhihua [1 ]
Wu, Xuezhong [1 ]
机构
[1] Natl Univ Def Technol, Coll Mechatron Engn & Automat, Lab Sci & Technol Integrated Logist Support, Changsha, Hunan, Peoples R China
来源
关键词
accelerometer; temperature self-calibration; fully differential; integrated capacitor; MEMS ACCELEROMETER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a new silicon MEMS torsional accelerometer with self-calibration against dynamic temperature environment by taking two structure optimizations compared with the conventional torsional accelerometers: a fully differential configuration and an integrated reference capacitor configuration. The fully differential configuration realizes the self-calibration of the acceleration measurement, by making the two pairs of differential structures have the same sensitivity to temperature but opposite sensitivity to acceleration. And the integrated reference capacitor configuration realizes the self calibration of the signal transform, by transferring the temperature sensitive reference capacitor from ASIC or PCB to the micro structure. Comparing tests show that output drift in the full temperature range of the accelerometer has a great improvement, from 910 mg to 61 mg, which experimentally demonstrates the effectivity of the two configuration optimizations.
引用
收藏
页码:991 / 994
页数:4
相关论文
共 50 条
  • [21] A self-calibrating delay-locked delay line with shunt-capacitor circuit scheme
    Baronti, F
    Lunardini, D
    Roncella, R
    Saletti, R
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2004, 39 (02) : 384 - 387
  • [22] Self-calibrating lensless inline-holographic microscopy by a sample holder with reference structures
    Riesenberg, Rainer
    Kanka, Mario
    OPTICS LETTERS, 2014, 39 (17) : 5236 - 5239
  • [23] AN EVALUATION OF A SELF-CALIBRATING INFRARED RADIOMETER FOR MEASURING SEA-SURFACE TEMPERATURE
    THOMAS, JP
    KNIGHT, RJ
    ROSCOE, HK
    TURNER, J
    SYMON, C
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1995, 12 (02) : 301 - 316
  • [24] MODELING A SELF-CALIBRATING THERMOCOUPLE FOR USE IN A SMART TEMPERATURE-MEASUREMENT SYSTEM
    RUPPEL, FR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (06) : 898 - 901
  • [25] A nano/micro 'meso' scale self-calibrating integrated optical wavelength and intensity meter
    Caulfield, H. J.
    Zavalin, A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 84 (1-2): : 275 - 279
  • [26] A nano/micro ‘meso’ scale self-calibrating integrated optical wavelength and intensity meter
    H.J. Caulfield
    A. Zavalin
    Applied Physics B, 2006, 84 : 275 - 279
  • [27] Self-calibrating differential predictive floating-point analog-to-digital converter
    Groza, V
    Debski, M
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1604 - 1606
  • [28] A Real-Time and Self-Calibrating Algorithm Based on Triaxial Accelerometer Signals for the Detection of Human Posture and Activity
    Curone, Davide
    Bertolotti, Gian Mario
    Cristiani, Andrea
    Secco, Emanuele Lindo
    Magenes, Giovanni
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (04): : 1098 - 1105
  • [29] Demonstration of a dual-mode Si detector as a self-calibrating device at room temperature
    Nordsveen, Marit Ulset
    Tang, Chi Kwong
    Gran, Jarle
    OPTICS EXPRESS, 2017, 25 (08): : 8459 - 8469
  • [30] Fabrication of lanthanide complexes in metal-organic frameworks as self-calibrating temperature sensor
    Li, Xiu-Zhen
    Diao, Xi-Hui
    Yan, Jun-Jiang
    Liu, Na
    Muhammad, Yaseen
    Chen, Chao
    Wang, Hao
    Qi, Chuan-Song
    Li, Wei
    JOURNAL OF SOLID STATE CHEMISTRY, 2024, 340