Objectives: We hypothesize that the change in the left ventricular (LV) diastolic pattern (DP) may be measured with high reproducibility and correlates with exercise echocardiography (EE) better than the ratio of early LV inflow velocity to early diastolic annulus velocity (E/e' index). Background: The E/e' index has been related to LV filling pressures but has not been compared with DP. Methods: We selected 179 consecutive patients who were referred for EE. Early (E) and late (A) LV inflow velocities by conventional pulsed Doppler, and septal annulus e' velocity by pulsed Doppler myocardial imaging were measured at rest (R) and post-exercise (PE). Results: Four LV-DPs were found: abnormal relaxation (AR) at R and PE (E < A) in 110 patients; AR at PE (E > A at R; E < A at PE) in 22 patients; restrictive pattern (RP) at R and PE (E > A) in 18 patients; and RP at PE (E < A at R; E > A at PE) in 29 patients. The more accurate PE cutoff E/e' values to predict abnormal EE, ischemic response, poor functional capacity (<8 Mets in men; <6 Mets in women), and lack of increase in left ventricular ejection fraction (LVEF) were 12, 12, 11, and 11 (areas under the curve were 0.53, 0.53, 0.63, and 0.57, respectively). Corresponding areas under the curve for an RP at R + PE or only at PE were 0.57, 0.55, 0.54, and 0.56 (P = not significant). The sensitivity of an RP at R + PE or only at PE was lower and the specificity was higher than those of the different E/e' cutoff values for predicting abnormal EE, functional capacity, ischemic response, and lack of increase in LVEF. Achieved Mets were lower in patients with an RP at R + PE or only at PE irrespectively of the E/e' values, whereas achieved Mets in patients with AR at R + PE or only at PE were lower if the E/e' was >= 11 (8.2 +/- 2.9 vs. 9.8 +/- 3.1, P =.01). Interobserver and intraobserver concordance were 95% (kappa = 0.86) and 100% (kappa = 1.0) for an RP, and 86% (kappa = 0.73) and 92% (kappa = 0.78) for a PE-E/e' value of >= 11. Conclusions: E/e' does not allow further stratification in patients with exercise RP. We propose both measurement of E/e' and determination of the LV-DP (a quickly assessable variable) for the assessment of diastolic function during EE. However, when an RIP persists or develops with exercise, further assessment may not be more informative.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 50 条
  • [41] Annulus paradoxus - Transmitral flow velocity to mitral annular velocity ratio is inversely proportional to pulmonary capillary wedge pressure in patients with constrictive pericarditis
    Ha, JW
    Oh, JK
    Ling, LH
    Nishimura, RA
    Seward, JB
    Tajik, AJ
    CIRCULATION, 2001, 104 (09) : 976 - 978
  • [42] Unique features of early diastolic mitral annulus velocity in constrictive pericarditis
    Sohn, DW
    Kim, YJ
    Min, HS
    Kim, KB
    Park, YB
    Choi, YS
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (03) : 222 - 226
  • [43] Relationship between the ratio of peak early diastolic transmitral flow and mitral annular velocities and the plasma B-Type natriuretic peptide (BNP) concentration in patients with atrial fibrillation: Assessment by simultaneous recording of transmitral flow and mitral annular velocity
    Kusunose, Kenya
    Yamada, Hirotsugu
    Niki, Hiroyuki
    Nakajima, Tomohiro
    Yamaguchi, Koji
    Koshiba, Kunihiko
    Kawano, Tomohito
    Soeki, Takeshi
    Wakatsuki, Tetsuzo
    Ito, Susumu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 137A - 137A
  • [44] The relation of the peak doppler E-wave to peak mitral annulus velocity ratio to diastolic function
    Lisauskas, J
    Singh, J
    Courtois, M
    Kovács, SJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (04): : 499 - 507
  • [45] A computational fluid mechanical study on the effects of opening and closing of the mitral orifice on a transmitral flow velocity profile and an early diastolic intraventricular flow
    Nakamura, M
    Wada, S
    Mikami, T
    Kitabatake, A
    Karino, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2002, 45 (04) : 913 - 922
  • [46] Echocardiographic determination of left atrial function and its application for assessment of mitral flow velocity pattern
    Zhang, GC
    Yasumura, Y
    Uematsu, M
    Nakatani, S
    Nagaya, N
    Miyatake, K
    Yamagishi, M
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 72 (01) : 19 - 25
  • [47] Evaluation of left ventricular diastolic function when mitral E and A waves are completely fused: Role of assessing mitral annulus velocity
    Sohn, DW
    Kim, YJ
    Kim, HC
    Chun, HG
    Park, YB
    Choi, YS
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (03) : 203 - 208
  • [48] Diabetes and diastolic function:: Stiffness and relaxation from transmitral flow
    Riordan, MM
    Chung, CS
    Kovács, SJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (12): : 1589 - 1596
  • [49] Pulsed tissue Doppler evaluation of mitral annulus motion:: a slew window to assessment of diastolic function
    Lindström, L
    Wranne, B
    CLINICAL PHYSIOLOGY, 1999, 19 (01): : 1 - 10
  • [50] Effect of preload change on transmitral antegrade flow and movement of mitral annulus in hypertensive patients
    Poznic, N. Nina Glavnik
    Podbregar, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 302 - 303