Evaluation of an automated chemiluminescent immunoassay for complexed PSA on the Bayer ACS:180™ system

被引:2
|
作者
Datta, P
Dasgupta, A
机构
[1] Bayer Corp, Div Diagnost, Tarrytown, NY 10591 USA
[2] Univ Texas, Sch Med, Dept Pathol & Lab Med, Houston, TX 77030 USA
关键词
automated chemiluminescent immunoassay; complexed PSA; ACS : 180 (TM) methods; ACCESS methods; evaluation;
D O I
10.1002/jcla.10089
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Prostate-specific antigen (PSA), the most important tumor marker for the detection of prostate cancer, exists in serum in a free, uncomplexed form (free PSA [fPSA]), and as bound to protease inhibitors (mainly alpha1-antichymotrypsin [ACT]). The measurement of complexed PSA (cPSA) concentration in serum has been shown to have better sensitivity and specificity than serum total PSA concentration. A new chemiluminescent immunoassay for cPSA for use on the Bayer ACS:180(TM) fully automated system (Bayer Corp., Tarrytown, NY) has been developed and evaluated. The precision of the new assay was <3.9% (within-run coefficient of variation [CV]) and <5.0% (total CV). The analytical sensitivity (95% upper limit of noise at zero calibrator) was <0.03 ng/mL. A comparison of the ACS:180(TM) cPSA results with the cPSA concentrations calculated from the ACCESS (Beckman-Coulter) PSA and fPSA assays yielded the following regression equation: ACS:180(TM) cPSA = 0.93* (calculated ACCESS cPSA) +0.43, R = 0.993, n = 95. The mean dilution and spike recovery for five samples were both 98%. No interference was observed from hemoglobin, triglyceride, or bilirubin (NCCLS protocol). These results indicate that the ACS:180(TM) cPSA assay is precise, and compares well with the calculated cPSA from ACCESS total and free-PSA results.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 50 条
  • [11] Automated valproic acid immunoassay on the Bayer Advia Centaur® and ACS:180® systems.
    Connolly, PB
    Barbarakis, L
    Junjulas, J
    Peter, M
    Kumar, H
    Ranadive, G
    CLINICAL CHEMISTRY, 2002, 48 (06) : A46 - A46
  • [12] Development of a myoglobin assay for diagnosis of acute myocardial infarction on an automated chemiluminescent immunoassay system, ACS:180.
    Spicer, N
    Hanratty, S
    Harriman, T
    Oh, SK
    Bluestein, B
    CLINICAL CHEMISTRY, 1997, 43 : 38 - 38
  • [13] THE CIBA CORNING ACS-180 AUTOMATED IMMUNOASSAY SYSTEM
    DUDLEY, RF
    JOURNAL OF CLINICAL IMMUNOASSAY, 1991, 14 (02): : 77 - 82
  • [14] EVALUATION OF CIBA-CORNING ACS-180(TM) AUTOMATED IMMUNOASSAY SYSTEM
    MORABRUGUES, J
    GASCONROCHE, N
    RODRIGUEZESPINOSA, J
    CORTESRIUS, M
    GONZALEZSASTRE, F
    CLINICAL CHEMISTRY, 1994, 40 (03) : 407 - 410
  • [15] Development of a Troponin-I test for diagnosis of acute myocardial infarction on an automated chemiluminescent immunoassay system, ACS:180(R).
    Oh, SK
    Woodbury, C
    Bluestein, B
    CLINICAL CHEMISTRY, 1996, 42 (06) : 123 - 123
  • [16] Evaluation of equimolarity between free and ACT-complexed PSA with a new automated chemiluminescent PSA assay.
    Datta, P
    Tasaico, K
    CLINICAL CHEMISTRY, 2000, 46 (06) : A163 - A163
  • [17] Evaluation of ACS:180(R) automated chemiluminescent assays for phenobarbital, phenytoin, theophylline, and vancomycin
    Lawson, GM
    Hinz, VS
    Cody, TJ
    Klee, GG
    CLINICAL CHEMISTRY, 1996, 42 (06) : 522 - 522
  • [18] THE ANALYTICAL PERFORMANCE OF THE CIBA-CORNING ACS-180 AUTOMATED IMMUNOASSAY SYSTEM - A MULTICENTER EVALUATION
    ROMER, M
    HAECKEL, R
    CAPELLI, M
    ROCIPON, J
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1994, 32 (05): : 395 - 407
  • [19] Development and clinical evaluation of ACS free PSA, an automated immunoassay to measure free PSA in serum.
    Tewari, PC
    Keelan, M
    Christensen, S
    Worswick, M
    Roth, HJ
    Huber, J
    Hofmann, E
    Carl, P
    CLINICAL CHEMISTRY, 1997, 43 : 583 - 583
  • [20] Measuring complexed PSA by an automated immunoassay to improve specificity.